background image

IM 05D01D02-03E (1)

C

A

B

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

FL is displayed if you 
press the             key 

when PID = MENU. 

Pressing the 

             key when 

PID = 4Gr causes PID 

for 4.SP to appear. 

ON/OFF rate

The setpoints of the ORB, ORH and ORL parameters are only 
effective when a sensor grounding alarm is used.  
The OR parameter represents the moving average (for 5 cycle times) 
of the control output and is not a setpoint.

If you become unsure of key operation during parameter 
setting, hold down the           key for more than 3 seconds. 
This returns you to the display at power-on 
(i.e., operating display). 

?

SET/ENT

Displays a 
setpoint.

Displays a

 parameter

 symbol.

Nothing appears.

Displays the

 operating

 parameter

 menu symbol

 “OP.PA”.

Target

Setpoint

Heater burnout 

current setpoint 1

Heater burnout 

current setpoint 2

Heater burnout 

current measurement 1

Heater burnout 

current measurement 2

SET/ENT

key

SET/ENT

key

SET/ENT

SET/ENT

key

SET/ENT

Pressing the 

             key when 

PID = 3Gr causes PID 

for 3.SP to appear. 

SET/ENT

Pressing the 

             key when 

PID = 2Gr causes PID 

for 2.SP to appear. 

SET/ENT

Pressing the 

             key when 

PID = 1Gr causes PID 

for 1.SP to appear. 

SET/ENT

SET/ENT

SET/ENT

SP display

Heating-side output display

Heating-side 
output-value 

symbol “H”

Output-value

symbol “o“

Cooling-side output display

SET/ENT

key

SET/ENT

key

SET/ENT

SET/ENT

Output

value

%

1. Setting display can be switched (moved) using the             key. 

2. A numerical value is changed by 

   (1) Using the        or        key to change a displayed value (decimal point blinking) and 

   (2) Pressing the             key to register it. 

3. Pressing the             key on an operating display (for more than 3 seconds) brings you to the 

operating parameter setting display. 

4. Pressing the             key on the operating parameter setting display (for more than 3 seconds) 

returns you to the operating display. 

5. Pressing the             key on the setup parameter setting display (for more than 3 seconds) 

returns you to the operating display.

You cannot return to the operating parameter setting display from the setup parameter setting 

display.

Operating Parameter Setting Display

Password input

(No password is required 
when PWD = 0.)

Press this key for more 

than 3 seconds to 

move to the operating 

parameter setting 

display. 

key

SET/ENT

Press this key for 

more than 3 seconds

to move to the 

operating
 display. 

key

Power on

Display?

IN = OFF

Yes

No

Determine PV input type first. 

Settings herein are described in “

2. Setting PV Input Type 

(Setting First at Power-on)”, in 

Initial Settings User’s Manual 

 . 

Display example

Display example

Press the                key to register 
the value. 

2.

1. Use the         or         key to set a numerical value. 

See 

Instrument Input Range Codes in  

 

Initial Settings User’s Manual 

 . 

After PV input type (IN), input/output 
parameters such as PV input unit (UNIT), 
maximum value of PV input range (RH), 
and minimum value of PV input range 
(RL) will be displayed. 

SET/ENT

SET/ENT

SET/ENT

SET/ENT

SET/ENT

SP display

OUT display

Operating Display

Operating Display for Heating/Cooling Control

Alarm-2 setpoint 

Alarm-3 setpoint 

Alarm-1 setpoint 

Displayed in automatic 
operation

Not displayed when 
OT parameter set to 4 to 6.

Target setpoint 

number selection

Setpoint ramp-up rate

Setpoint ramp-down rate

ON/OFF rate 

detection band

ON/OFF rate high limit

ON/OFF rate low limit

Target setpoint-1

Target setpoint-2

Target setpoint-3

Target setpoint-4

Cooling-side 

proportional band

Cooling-side integral time

Cooling-side 

derivative time

Dead band

Displayed for 
heating/cooling 
control

Displayed for 
heating/cooling 
control

LL communication 

interface selection

Auto-tuning

SUPER function

PID parameter 

display number 

PV input filter

PV input bias

ON/OFF control hysteresis/

heating-side/cooling-side 

ON/OFF control hysteresis

Direct/reverse 

action switching

Displayed for 
ON/OFF control

Proportional band / heating-

side proportional band 

 Integral time / heating-

side integral time 

Derivative time / heating-

side derivative time 

Manual reset

Zone PID reference 

point-1

Not displayed for 
ON/OFF control

Displayed when 
integral time is OFF

Displayed when 
parameter ZON=ON

or

key

SET/ENT

To switch the parameter display, press the             key. 

key

key

Menu

Menu

Blinks during 

change. 

Basic Key Operation Sequence

Output high limit/heating-

side output high limit

Output low limit/cooling-

side output high limit

Description of Operating Parameter Setting Display

Description of Operating Parameter Menu Display 

Cooling-side
output-value

symbol “C”

Cooling-side

output

%

Heating-side

output

%

Heating-side OUT display

Cooling-side OUT display

This manual contains a parameter map as a guideline for setting parameters, and lists of parameters for recording User
Settings.

Contents

1. Basic Key Operation Sequence and Parameter Map
2. Lists of Parameters

1. Basic Key Operation Sequence and Parameter Map

List of Alarm Types

The table below shows the alarm types and alarm actions.
In the table, codes 1 to 10 are not provided with stand-by actions, while codes 11 to 20 are provided with stand-by actions.

Alarm action

Alarm action

Alarm type code

Alarm type code

Alarm type

 “Open/close” shows status of relay contact, 
and “lit” and “unlit” shows status of lamp

Contact 

closes 

if alarm 

occurs

Contact 

opens 

if alarm 

occurs

Contact 

closes 

if alarm 

occurs

Contact 

opens 

if alarm 

occurs

Alarm type

No alarm

OFF

PV high limit 

PV low limit 

Alarm setpoint

Closed (lit)

Hysteresis

PV

Open (unlit)

1

11

De-energized 

on deviation low 

limit alarm 

Deviation

setpoint

Target SP

Open (lit)

Hysteresis

PV

Closed 
(unlit)

6

16

Closed (lit)

Open (unlit)

Open (unlit)

Closed (lit)

Closed (lit)

Open (unlit)

Open (unlit)

Closed (lit)

Closed (lit)

Hysteresis

Open (unlit)

Alarm setpoint

PV

2

12

Deviation high 

and low limits

Target SP

PV

Hysteresis

Hysteresis

Deviation setpoint

Closed

 (lit)

Open 
(unlit)

Closed 

(lit)

7

17

Deviation high  

limit

Hysteresis

PV

Open (unlit)

Target SP

Deviation setpoint

Closed (lit)

3

13

Deviation within 

high and low 

limits 

Deviation setpoint

Target SP

PV

Hysteresis

Hysteresis

Open 
(unlit)

Open

 (unlit) 

Closed 

(lit) 

8

18

Deviation low 

limit

PV

Target SP

Deviation setpoint

Open (unlit)

Hysteresis

Closed (lit)

4

14

De-energized

on PV high limit

De-energized

on PV low limit 

PV

Open (lit)

Alarm setpoint

Hysteresis

Closed

 (unlit)

9

19

De-energized on 

deviation high 

limit alarm

PV

Open (lit)

Target SP

Deviation 

setpoint

Hysteresis

Closed
 (unlit)

5

15

Alarm setpoint

Hysteresis

PV

Open (lit)

Closed 

(unlit)

10

20

SP high

limit

SP low 

limit

Alarm setpoint

Hysteresis

SP

Output high 

limit

Alarm setpoint

Output value

Hysteresis

Hysteresis

Alarm setpoint

SP

Output low 

limit

Hysteresis

Alarm setpoint

Output value

“Open/close” shows status of relay contact, 
and “lit” and “unlit” shows status of lamp

Fault diagnosis
output (Note 1)

FAIL output

(Note 2)

Heater burnout

alarm 2

Heater burnout

alarm 1

Fault diagnosis output

The controller stops when in a FAIL state.
The control output is set to “OFF” or “0%” 
and alarm output is set to “OFF”.

Sensor grounding

alarm

Sensor grounding alarm

Heater burnout alarms 1 and 2

28

29

30

31

24

25

21

23

22

Treated 

as normal

C

Power-on

Time

The alarm output does not 
turn on in this region even 
if the PV value is below the 
low limit of the alarm setpoint.

Low limit of 
alarm setpoint

Normal

Abnormal

 The alarm 

output turns on.

Stand-by Action

It is effective in the following cases where;
- the power is turned on
- the target setpoint is changed
- the target setpoint number is switched
  (however, except for remote setpoint)

Instrument Input Range Codes

Input

Type

Instrument Input 
Range Code

Instrument 
Input Range 

1
2

K

J

4
5

T

6

B

7

S

8

R

9

N

10

E

11

L(DIN)

12
13

U(DIN)

14

W

15
16

PR20-40

17

W97Re3-
W75Re25

18

30

JPt100

31
35
36

Pt100

37
40
41
50
51
55
56

-200 to 1370

°

C

-199.9 to 999.9

°

C

-199.9 to 500.0

°

C

-199.9 to 999.9

°

C

-199.9 to 400.0

°

C

0.0 to 400.0

°

C

0 to 1800

°

C

0 to 1700

°

C

0 to 1700

°

C

-200 to 1300

°

C

-199.9 to 999.9

°

C

-199.9 to 900.0

°

C

-199.9 to 400.0

°

C

0.0 to 400.0

°

C

0 to 2300

°

C

0 to 1390

°

C

0 to 1900

°

C

0 to 2000

°

C

-199.9 to 500.0

°

C

-150.0 to 150.0

°

C

-199.9 to 640.0

°

C

-199.9 to 500.0

°

C

-150.0 to 150.0

°

C

0.400 to 2.000V
1.000 to 5.000V
0.000 to 2.000V

0.00 to 10.00V

-10.00 to 20.00mV

0.0 to 100.0mV

3

OFF

Thermocouple

Unspecified

Standard 
signal 

DC voltage

RTD

Platinel 2

0.4 to 2 V
1 to 5 V
0 to 2 V
0 to 10 V 
-10 to 20 mV
0 to 100 mV

Set the data item PV Input Type 
“IN” to the OFF option to leave 
the PV input type undefined.

NOTE

Changing the registered value of a setup parameter
may cause the registered value of an operating pa-
rameter to be initialized automatically. Thus, when
you have changed a setup parameter, always check
that the registered value of the operating parameter
is appropriate. If it is initialized to default, reset it to
the required value.

B

C

When shipped from the 
factory, this parameter 
appears first after 
power-on. 

Menu

This parameter 
is not to be set.

SET/ENT

SET/ENT

SET/ENT

A

SET/ENT

key

SET/ENT

key

Target setpoint

limiter upper limit

Target setpoint

limiter lower limit

Alarm-1 type

Alarm-2 type

Alarm-3 type

Alarm-1 hysteresis

Alarm- 2 hysteresis

Alarm- 3 hysteresis

Alarm-1 delay timer

Alarm- 2 delay timer

Alarm- 3 delay timer

Cooling-side control 

output cycle time

Control output cycle 

time / heating-side control 

output cycle time 

PID control mode

Zone PID selection

Anti-reset windup

Ramp-rate time unit 

Protocol selection

Baud rate

Parity

Stop bit

Data length

Address

Minimum response time

PV input type

(PV INPUT terminals)

PV input unit

Maximum value of PV 

input range

Minimum value of PV 

input range

PV input decimal point position

 (displayed at voltage input)

Maximum value of PV input 

scale (displayed at voltage input)

Minimum value of PV input 

scale (displayed at voltage input) 

Selection of PV input 

burnout action

Presence/absence of PV input 

reference junction compensation

Retransmission

output type

Maximum value of 

retransmission output scale

Minimum value of 

retransmission output scale

DI function selection

SELECT display-1 

registration

SELECT display-2 

registration

SELECT display-3 

registration

SELECT display-4 

registration

Control output type

Key lock

Password setting

Press this key for 

more than 3 seconds

to move to the 

operating
 display. 

key

Displayed only for 
controllers with 
communication 
functions

Preset output / heating-side

preset output

Cooling-side preset output

key

or

key

key

Controll function

related

Input/output 

related

Setup Parameter Setting Display

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

P V

MAN

A / M

S P

AL1

2

3

SP

2

3

4

S E T / E N T

Displays a setpoint. 

Displays a parameter 
symbol.

Nothing appears.

Displays a menu such as 
“FUNC” or “I/O”. 

Description of Setup Parameter Menu Display

Description of Setup Parameter Setting Display

Displayed 
for heating
/cooling 
control

Displayed 
for heating
/cooling 
control

Not displayed 
when OT 
parameter 
set to 4 to 6.

Note 1: The fault diagnosis output turns on in case of

input burnout, A/D converter failure, or refer-
ence junction compensation (RJC) failure. The
control output in case of input burnout or A/D
converter failure is set to the value of the PO
(Preset Output Value) setup parameter. In case
of RJC failure, the controller continues control
under the condition of “RJC = OFF”.

Note 2: The FAIL output is on during normal operation

and turns off in case of failure.

IM 05D01D02-03E

User’s
Manual

3rd Edition: Sep 30, 2004

Models UT350 / UT320
Digital Indicating Controllers
User’s Manual

   Parameters

Содержание UT320

Страница 1: ... RTD input Maximum 150 wire Conductor resistance between three wires should be equal However 10 wire for a maximum range of 150 0 to 150 0 C Wire resistance effect 0 1 C 10 Allowable input voltage 10 V DC for thermocouple mV or RTD input 20 V DC for DC voltage input Noise rejection ratio 40 dB 50 60 Hz or more in normal mode 120 dB 50 60 Hz or more in common mode Reference junction compensation er...

Страница 2: ...roportional PID relay contact output is configured at factory before shipment 23 24 RS 485 communication Wiring can only be carried out for controllers with communication functions Maximum baud rate 9600 bps 25 26 27 SDB SDA RDB RDA SG 24 V DC loop power supply Wiring can only be carried out for controllers with 24 V DC loop power supply 21 6 28 0VDC 30 mA DC max 21 22 8 9 Power supply 10 L N Allo...

Страница 3: ...300 F 300 to 750 F 199 9 to 750 0 F 32 to 4200 F 32 to 2500 F 32 to 3400 F 32 to 3600 F 199 9 to 999 9 F 199 9 to 300 0 F 300 to 1560 F 199 9 to 999 9 F 0 1 of instrument range 1 digit Note1 Note2 RTD Pt100 37 150 0 to 150 0 C 199 9 to 300 0 F 0 2 of instrument range 1 digit Note1 0 4 to 2 V 40 Standard signal 1 to 5 V 41 0 to 2 V 50 0 to 10 V 51 0 400 to 2 000 V 1 000 to 5 000 V 0 000 to 2 000 V ...

Страница 4: ... 2 3 4 SET ENT PV MAN A M SP AL1 2 3 SP 2 3 4 SET ENT PV MAN A M SP AL1 2 3 SP 2 3 4 SET ENT Displays PV Displays target setpoint Displays target setpoint MAN lamp ON Displays output value Displays output value symbol o MAN lamp OFF 8 Manipulating the Control Output in Manual Operation NOTE Control output cannot be changed if the controller is stopped In this case the preset output value setup par...

Страница 5: ...mit alarm Deviation setpoint Target SP Open lit Hysteresis PV Closed unlit 6 16 Closed lit Open unlit Open unlit Closed lit Closed lit Open unlit Open unlit Closed lit Closed lit Hysteresis Open unlit Alarm setpoint PV 2 12 Deviation high and low limits Target SP PV Hysteresis Hysteresis Deviation setpoint Closed lit Open unlit Closed lit 7 17 Deviation high limit Hysteresis PV Open unlit Target S...

Страница 6: ...1 4 communi cation function 0 0 of PV input range 0 0 to 100 0 of PV input range where SPL SPH Places a limit on the range within which the target setpoint is changed SPH SPL Control output cycle time Heating side control output cycle time in heating cooling control Cooling side control output cycle time 1 to 1000 second 30 second 1 to 1000 second 30 second CT CTc Preset output Heating side preset...

Отзывы: