User’s

Manual

Model UPM100, UPM101

Universal Power Monitor

<Parameter Maps>

This manual describes the parameter maps showing the flow of measured value 

 

displays and parameter displays. It also provides a summary of the measuring ranges 

and parameter setting ranges for reference purposes.

1. Basic Key Operations and Parameter Maps ------- P.1 

2. Display Ranges for Measured Values --------------- P.2 

3. Setting Ranges for Parameters ----------------------- P.2 

1.  Basic Key Operations and Parameter Maps

COMM2

Basic Key Operations

Power-On

Measured Value Display

Parameter Setting Display

Without reactive power 

measuring function

Without 

op

tional 

me

asuring fu

nc

tion

Without optional  measuring function

Without optional  measuring function

After the address (station number)

is di splayed for about 5 seconds,

a measured value is displayed.

Hold down for about 3 seconds.

<On the Measured Value Display>

This key can be used to change measured value displays.

When you hold it down for about 3 seconds, the display changes to

the parameter setting display.

When you press this key while a instantaneous voltage/current is

displayed, the maximum value is displayed.

When you press this key while electric energy is displayed, three

digits after the decimal point can be displayed depending on the

measurement conditions.

<On the Parameter Setting Display>

This key is used to display and enter settings.

Press it three times (four times for CT ratio) to display the next

parameter without changing the setting

This key is used to change the numeric value digit and to move the

decimal point position.

These keys are used to increase/decrease a set numeric value and to

change a selection.

<Display Flow for Individual Parameters>

A

B

A

A

A

A

A

A

A

A

A

A

A

A

A

A

With integrated pulse output

If there is no ke

y action for about 

5 minutes, th

e display automatically 

returns to the measured value display.

Active Energy

LAG Reactive Energy

LEAD Reactive Energy

Apparent Energy

Optional Electric Energy

Instantaneous Active/Regenerative Power

Instantaneous Reactive Power

Instantaneous Apparent Power

Instantaneous Voltage

Instantaneous Current

Instantaneous Power Factor

Frequency

Maximum Voltage

Minimum Voltage

Maximum Current

The following can be displayed

for each phase depending on

the specifications.
• Instantaneous voltage

• Maximum voltage

• Minimum voltage

At maximum, three digits after the decimal point can be

displayed depending on the measurement conditions.

VT Ratio

CT Ratio

RS-485 Communication Protocol

RS-485 Communication Address (Station)

RS-485 Communication Baud Rate

RS-485 Communication Parity

RS-485 Communication Stop Bit

RS-485 Communication Data Length

Integral Low-cut Power

Standby Mode

Standby Mode Timer

Pulse Unit-1 of Electric Energy

ON Pulse Width-2 of Electric Energy

Pulse Unit-2 of Electric Energy

Electric Energy LAG/LEAD/REGENE

A

    Set value change display

    Set value confirmation display

    Enter the value (and display

     the next parameter)

B

    Decimal point position change

     display

    Set numeric value change

     display

    Set value confirmation display

    Enter the value (and display

     the next parameter)

Regenerative Energy

A minus sign (-) is always displayed for

regenerative power measurement.

At maximum, three digits after the decimal point can be

displayed depending on the measurement conditions.

At maximum, three digits after the decimal point can be

displayed depending on the measurement conditions.

At maximum, three digits after the decimal point can be

displayed depending on the measurement conditions.

At maximum, three digits after the decimal point can be

displayed depending on the measurement conditions.

The following can be displayed

for each phase depending on

the specifications.
• Instantaneous current

• Maximum current

When you press this key while an instantaneous voltage is displayed,

the minimum value is displayed.

(1)

(2)

(3)

(1)

(2)

(3)

(4)

ON Pulse Width-1 of Electric Energy

In this manual, the “UPM100” means the “UPM100” or “UPM101,”

and the illustrations show the “UPM100 with display function.”

11

IM 77C01J01-00EN

Содержание UPM101

Страница 1: ...ribes how the operator should exercise special care to avoid electric shock or other dangers that may result in injury or loss of life This label denotes that a protective ground terminal is necessary...

Страница 2: ...d crimp on terminals for use in connecting to the input and power supply terminals B d 2 d 2 B Round Type Open end Type Round Type Specification Size d 2 Size B Recommended Tightening Torque Applicabl...

Страница 3: ...1L 2S 2L 3S 3L Dedicated CT RS 485 Signal ground Power supply Pulse output 1 of electric energy Pulse output 2 of electric energy Load Established instruments Established CT Established CT Fuse Dedica...

Страница 4: ...rgy 2 of rdg with rated input Active energy 2 of rdg with rated input integration not performed on minus side Reactive energy 2 of rdg with rated input for UPM101 with optional measuring function Rege...

Страница 5: ...about 5 seconds and then the display is changed to the measured value display To change measured value display To change to the parameter setting display Each time you press the SET ENT key on the mea...

Страница 6: ...hat the product of the ratio does not exceed 9999 MW by calculated by secondary side rated power VT ratio CT ratio For the UPM101 set the CT ratio of the established CT where the dedicated CT is to be...

Страница 7: ...d display the next parameter Next press the Move key to make the first digit flash Hold the SET ENT key down for about 3 seconds to return to the measured value display 6 2 Settings Related to Integra...

Страница 8: ...splay the parameter set value Press the Up key or Down key to display ON or OFF After setting the parameter press the SET ENT key once All digits flash confirmation display Press the SET ENT key on th...

Страница 9: ...Integral resolution kWh Down key Move key Up key SET ENT key Measured value display Communication light Power light COS light RST light Integrated pulse light Unit light IMPORTANT Pressing this switch...

Страница 10: ...rgy 3 1 Resetting Voltage Maximum Minimum Values and Current Maximum Value The following procedure simultaneously resets voltage maximum value voltage minimum value and current maximum value Measured...

Страница 11: ...Energy Apparent Energy Optional Electric Energy Instantaneous Active Regenerative Power Instantaneous Reactive Power Instantaneous Apparent Power Instantaneous Voltage Instantaneous Current Instantan...

Страница 12: ...A 100VA or greater but less than 1kVA 0 0 to 999 9 VA 1kVA or greater but less than 10kVA 0 to 9999 VA 10kVA or greater but less than 100kVA 0 00 to 99 99 kVA 100kVA or greater but less than 1MVA 0 0...

Отзывы: