YOKOGAWA TB820D Скачать руководство пользователя страница 2

2

IM 12E01B30-01EN

1st Edition : Mar. 30, 2021-00

u

 INTRODUCTION

Thank you for purchasing TB820D Right Angle Scatterd Light Turbidity Detector.

This User’s Manual contains all essential information for the user to make full use of TB820D.

Please read the following respective documents before installing and using the instrument.

The related documents are listed as follows.

General Specifications

Contents

Document number

Note

TB820D, FLXA402T Right Angle 

Scattered Light Turbidity Analyzer

GS 12E01B30-01EN

Online manual

“EN” in the document number is the language code.

User’s Manual

Contents

Document number

Note

TB820D Right Angle Scattered Light

Turbidity Detector

Start-up and Safety Precautions

IM 12E01B30-01EN

Attached to the product (printed manual) 

(This manual)

TB820D Right Angle Scattered Light

Turbidity Detector

IM 12E01B30-02EN

Online manual 

FLXA402T Liquid Analyzer for Turbidity 

and Chlorine

Start-up and Safety Precautions

IM 12A01G01-01EN

Attached to the product (printed manual)

FLXA402T Liquid Analyzer for Turbidity 

and Chlorine

Installation and Wiring

IM 12A01G01-02EN

Online manual 

FLXA402T Liquid Analyzer for Turbidity 

and Chlorine

Operation of Converter

IM 12A01G01-03EN

Online manual

FLXA402T Liquid Analyzer for Turbidity 

and Chlorine

Operation of pH

IM 12A01G02-01EN

Online manual

FLXA402T Liquid Analyzer for Turbidity 

and Chlorine

Operation of SC

IM 12A01G03-01EN

Online manual

“EN” in the document number is the language code.

An exclusive User’s Manual might be attached to the products whose suffix codes or option codes 

contain the code “Z” (made to customers’ specifications). Please read it along with this manual.

Technical Information

Contents

Document number

Note

FLXA402T Liquid Analyzer for Turbidity 

and Chlorine

MODBUS Communication

TI 12A01G01-62EN

Online manual

“EN” in the document number is the language code.

You can download the latest

 

documents

 

from our website. Scan QR code.

http://www.yokogawa.com/an/flxa402t/download/

Refer to each corersponding manual for other related products.

No. IM 12E01B30-01EN 

1st Edition : Mar. 2021 (YK)

All Rights Reserved Copyright © 2021, Yokogawa Electric Corporation

Содержание TB820D

Страница 1: ...User s Manual TB820D Right Angle Scattered Light Turbidity Detector Start up and Safety Precautions IM 12E01B30 01EN IM 12E01B30 01EN 1st Edition...

Страница 2: ...the product printed manual FLXA402T Liquid Analyzer for Turbidity and Chlorine Installation and Wiring IM 12A01G01 02EN Online manual FLXA402T Liquid Analyzer for Turbidity and Chlorine Operation of...

Страница 3: ...and service Yokogawa products and parts are guaranteed free from defects in workmanship and material under normal use and service for a period of typically 12 months from the date of shipment from th...

Страница 4: ...ging Repair work should be done at grounded workstations using grounded soldering irons and wrist straps to avoid electrostatic discharge CAUTION The Instrument is packed carefully with shock absorbin...

Страница 5: ...safety symbols are used on the product as well as in this manual WARNING This symbol indicates that an operator must follow the instructions laid out in this manual in order to avoid the risks for the...

Страница 6: ...6 IM 12E01B30 01EN 1st Edition Mar 30 2021 00 u Compliant Standards EMC RCM EN 55011 Class A Group 1 Korea Electromagnetic Conformity Standard Class A...

Страница 7: ...ose for RCM General purpose for KC General purpose Relay box for solenoid valve NN A5 Without relay box for solenoid valve Relay box for solenoid valve Ultrasonic cleaning NN U1 Without ultrasonic cle...

Страница 8: ...d at or as near to room temperature as possible allows for sufficient maintenance space with easy maintenance access allows for drainage For information on FLXA402T read the user s manual Install the...

Страница 9: ...1 L 202 N 002 G U1 U2 U3 S L N G 32 NC 31 C 33 NO S1 42 NC 41 C 43 NO S2 72 NC 71 C 73 NO S4 61 62 mA1 65 66 mA2 81 82 mA3 85 86 mA4 21 22 24 SHLD 63 87 88 SHLD 89 A 91 B 92 GND 93 SHLD 94 Termination...

Страница 10: ...er switch Fix securely onto constructions or walls all power lines including wire cables of power supply by using stanchion cable rack conduit or vinyl band Unplugged cables are dangerous and may caus...

Страница 11: ...nused cable inlets with the supplied cable glands and close up plugs Refer to IM 12E01B30 02EN for details WARNING The minimum cross sectional area of the protective grounding wire should be 0 75 mm2...

Страница 12: ...n the smart box Connect the cable complying with the figure below Ground Terminal 101 102 201 202 301 302 Power Terminal To Converter terminal To Detector terminal n Wiring of PG400 For wiring PG400 c...

Страница 13: ...ng are all correctly provided 2 Set up the desiccant 3 Run water and check that there is no water leakage 4 Turn on the power and set to Maintenance mode 5 Configure parameters on the converter and de...

Страница 14: ...intain the housing s weatherproof integrity against water and water vapor The pH measurement uses high impedance sensors glass electrode Keep the moisture out of the converter inside CAUTION Never use...

Страница 15: ...ety Precautions 15 IM 12E01B30 01EN 1st Edition Mar 30 2021 00 Revision record Mar 2021 1st Edition Newly released Yokogawa Electric Corporation 2 9 32 Nakacho Musashino shi Tokyo 180 8750 JAPAN http...

Отзывы: