19
IM 04L51B01-18EN
I/O Messages
Type
Number
Operation type
Instance ID
Size
Data type
(GX/GP expandable I/O 6)
(GM sub unit 6)
6001 to 6050,
6101 to 6150
Producer
131
400 (4 x 100) INT32
6201 to 6250,
6301 to 6350
Producer
132
400 (4 x 100) INT32
6401 to 6450,
6501 to 6550
Producer
133
400 (4 x 100) INT32
Input/Output channel
(Continuous channel data
area)*
0001 to 0010,
0101 to 0110,
0201 to 0210,
0301 to 0310,
0401 to 0410,
0501 to 0510,
0601 to 0610,
0701 to 0710,
0801 to 0810,
0901 to 0910
Producer
136
400 (4 x 100) INT32
Computation channel
A001 to A100 Producer
137
400 (4 x 100) INT32
A101 to A200
147
400 (4 x 100)
Communication channel
(Read/Write)
C001 to C100 Producer /
Consumer
138
400 (4 x 100) INT32
C101 to C200 Producer /
Consumer
139
400 (4 x 100) INT32
C201 to C300 Producer /
Consumer
140
400 (4 x 100) INT32
C301 to C400 Producer /
Consumer
141
400 (4 x 100) INT32
C401 to C500 Producer /
Consumer
142
400 (4 x 100) INT32
-
Configuration
195
0
-
-
Producer /
Consumer
196
0
-
* The “continuous channel data area” is a special area that enables continuous reading by limiting
the number of channels of each module to 10.
For only the I/O channels on a GX/GP main unit or I/O channels on a GM main unit, this area
can be used to read data consecutively.