Wiring Diagrams

Voltage

or

Contact

2

Power Side

Load Side

K

1S

1L

P1
P2

PT

CT

L

L

N

GND

Power Supply

A
B
C

+

+

-

-

1

1

3

5

7

9

2

4

6

8

10

20

19

18

17

16

15

14

13

12

11

21

22

23

+   Receiver

  Device

Communication
Shield

Short Terminating

(R)

(S)

N

K

1S

1L

P1

2S

2L

P2

PT

CT

L

K CT

L

L

N

GND

A
B
C

1

2

1

3

5

7

9

2

4

6

8

10

19

18

17

16

15

14

13

12

11

20

21

22

23

Voltage

or

Contact

Power Side

Load Side

Power Supply

+

-

+

-

+   Receiver

  Device

Communication
Shield

Short Terminating

(R) (S)

(T)

1 phase 2 wire system

1 phase 3 wire system

2

K

1S

1L

P1

3S

3L

P3

P2

PT

CT

L

K CT

L

L

N

GND

A
B
C

1

3

1

3

5

7

9

2

4

6

8

10

19

18

17

16

15

14

13

12

11

20

21

22

23

Voltage

or

Contact

Power Side

Load Side

Power Supply

+

-

+

-

Communication
Shield

Short Terminating

(R) (S) (T)

+   Receiver

  Device

A

B

C

L

N

GND

N

3

2

PT

CT

K

L

K

L

CT

1

K

L

CT

1

3

5

7

9

2

4

6

8

10

19

18

17

16

15

14

13

12

11

20

21

22

23

Voltage

or

Contact

Power Side

Load Side

Power Supply

+

-

+

-

Communication
Shield

Short Terminating

(R)

(S)

(T)

+   Receiver

  Device

3 phase 3 wire system

3 phase 4 wire system

CAUTION

The following caution for safety should be taken for handling of product.  We are not respon-
sible for damage incurred by use contrary to caution.

The following items should be checked before turning power on.  Use of product
ignoring specifications may cause over heating or burning.
(a) Voltage of power supply and input value applied to the product should meet with

required specifications.

(b) External wiring to terminals should be connected correctly.

 (See precding Article 4)

When take off wiring from the product, check to see primary side of CT, PT and power
supply is in OFF status.  If CT secondary side is in OPEN status during operation, be
careful for danger of high voltage.

Do not use the product in such dangerous places where exist inflammable and explo-
sive gas or steam.

Содержание Powercert PR201

Страница 1: ...User s Manual IM 77C01C01 01E Model PR201 Power Monitor IM 77C01C01 01E 1st Edition ...

Страница 2: ...Blank Page ...

Страница 3: ...ounding 3 Turn off the product before installation and wiring 4 Use the power supply within specifications 5 Observe the following instructions for correct installation Recommended panel thickness is 1 to 10mm Install the product horizontally Install the product using attached fixture from the backside of the product Turn the screw only up to 180 after the screw touches the mounting panel to preve...

Страница 4: ...ut 1 2 110V can also be used at 120V input Note 3 Rated input 5 6 440V is the specs only for 1 phase 2 wire system and 3 phase 3 wire system Note 4 Rated input A to F is the specs for only 3 phase 4 wire system Rated input voltage indicates phase voltage A B 64V C D 127V E F 227V indicate 110V 3 220V 3 480V 3 respectively In case of 440V 3 input it can be used at E F 227V of rated input Note 5 Spe...

Страница 5: ...mensions R S T kWh Wh W V A 106 103 COMM COS φ SET ENT 110 110 0 5 15 15 66 82 4 96 45 Panel Thickness 1 to 10 2 Bolt M5 45 45 45 9 Screw M3 10 Screw M4 4 Screw M4 Short Bar When short ciruit end terminal ON Unit mm Panel Cut Dimension Minimum130 45 0 3 45 0 3 45 0 3 45 0 3 Minimum 117 φ101 Hole 2 φ6 Hole ...

Страница 6: ...and bottom of the product as shown in the figure below then tighten the screws of the brackets Take care not to overtighten them Insert the product into the opening at the front of the panel Directionm to insert the product Terminal Arrangement 10 8 6 4 2 9 7 5 3 1 23 22 21 20 19 18 17 16 15 12 11 14 13 F05 EPS T14 EPS 1 phase 2 wire TML No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 ...

Страница 7: ...K L CT 1 K L CT 1 3 5 7 9 2 4 6 8 10 19 18 17 16 15 14 13 12 11 20 21 22 23 Voltage or Contact Power Side Load Side Power Supply Communication Shield Short Terminating R S T Receiver Device 3 phase 3 wire system 3 phase 4 wire system CAUTION The following caution for safety should be taken for handling of product We are not respon sible for damage incurred by use contrary to caution The following ...

Страница 8: ...g items RS 485 station number data transmission rate lower limit of input range upper limit of input range PT ratio CT ratio in tegrating low cut power integrating pulse unit fixed point part exponent integrating pulse ON pulse duration 3 Adjustment items power momentary value in put zero power momentary value input span voltage momentary value input zero volt age momentary input span current mome...

Страница 9: ...rated pulse unit characteristic setting 4 Integrated pulse ON width setting 4 RS 485 communication protocol setting 4 RS 485 station number setting 4 RS 485 data baud rate setting 4 LON communication node number setting 4 LON communication integrated power data transmission period setting minute 4 LON communication integrated power data transmission period setting second 4 LON communication power ...

Страница 10: ...y 4 Change numeral column at pressing key 5 Change numeral column at pressing and key 6 Fixing numeral value at pressing key 7 Light on and off of setting value 8 If the setting is complete correctly press key If required correcting press any of key key and key then repeat from step 1 Example of Communication Connection RS232 C Converter RS232 C Cable Short circuit terminating 13 14 15 13 14 15 16...

Страница 11: ...er W Integrated pulse output Function Outputs pulse in proportion to integrated power Output signal Open collector Output capacity 200mA 30V DC Integrated pulse unit Indicates actual kWh corresponding 1 pulse input to this instrument It can be set through integrated pulse unit characteristic and mantissa sections on parameter setting screen Input Output Specifications Input Specs Phase wire system...

Страница 12: ...arts after optional integrated power is reset Backup when power off power meter Integrated power holds last integrated value when power off Optional integration has not this function Response speed of instantanous power analog output Within 1 second until enter into 1 of last value Up date of transmit data Power voltage current power factor within 500ms Insulation resistance 100MΩ 500V DC between ...

Страница 13: ...layed in data display Current display R S T Voltage display R S S T T R R S T 3 phase 4 wire system Range switch This switch is used for display line change over and for movement column position of setting data and decimal point position Numeric up switch This switch is used for increment of setting parameter and input output adjustment data Numeric down switch This switch is used for decrement of...

Страница 14: ... made noise or erroneous data would be ingnored Make time out disposal through upper computer Set time out time more than 1 second LON Communication Function Measuring data can be simply read out on personal computer through LON communication adapter and DDE server without consciousness of communication Also control of optional integration and initaialization of maximum and minimum values can be d...

Отзывы: