9
IM 77C01C01-01E
1st Edition : March 5.2001-00
■
Specifications
When outer set of PT, CT, check to see the primary side input
power is less than 10000 MW
and the value
calculated by the formula below is within above
input measuring range list.
Input range (W) = Primary side input power (W)
(PT ratio) x (CT ratio)
Rated power factor: LEAD 0.5 to 1 to LAG 0.5
<Optional integrated control signal>
Input point: 1 point
Input signal: contact or voltage
Contact signal
ON signal
OFF signal
below 200‰
over 100k‰
Voltage signal
–1V DC, below 200‰
4.5 to 25V DC
ON signal:
Optional integration start (reset, integration start)
OFF signal: Optional integration stop
(Note) Control of optional integration can also be made
through communication. Control by communication is
once made, only control by communication is once
made, only control by communication is made
thereafter.
Integratad lowcut power: Integrated lowcut power below
lowcut power is not made by integrated power,
optional integrated power and integrated pulse
output. Set integrated lowcut power for input to
this instrument .
Parameter setting
screen item
Setting
range
Integrated lowcut power
Fixed decimal point
0.5W when shipment
0.1 to 99.9W
Output Specs.
Output point: 1 point (commonly used for analog and
integrated pulse outputs)
<Analog Output>
Function: Conversion of output instantanous power into DC
current.
Output signal (instantanous power) : 4 to 20mA DC
Permissible load resistance: 0 to 750
Ω
Input scaling: Indicates instantanous power range to be
converted. Input scaling can be set by “H” and
“L” levls of analog output on parameter setting
screen. Set “L” and “H” levels within measur-
ing range of this instrument. Also set span
(difference between “L” level and “H” level) so
as it would be more than 50% of rated power. If
not specified when ordering, it would be shipped
“L” level at OW, and “H” level at rated power
(W).
<Integrated pulse output>
Function: Outputs pulse in proportion to integrated power
Output signal: Open collector
Output capacity:
200mA, 30V DC
Integrated pulse unit: Indicates actual kWh corresponding 1
pulse input to this instrument. It can be set
through integrated pulse unit characteristic and
mantissa sections on parameter setting screen.
●
Input & Output Specifications
Input Specs.
Phase & wire system: 1-phase 2-wire system, 1-phase 3-wire
system, 3-phase 3-wire system, 3-phase 4-wire
system
Input frequency:
45 to 65Hz
Rated input voltage: 110V AC, 220V AC, 440V AC,
3-phase 4-wire system: 64V AC, 127V AC,
277V AC
Permissible Input voltage: 1.2 times of rated voltage
(continuous) , 1.5 times (10 seconds)
Rated input current: 1A AC, 5A AC
Permissible Input current: 1.2 times of rated current
(coninuous) , 2 times (10 seconds),
10 times (3 seconds)
Input (power) measuring range (secondary side of PT, CT
when CT, PT are set)
•
1-phase 2-wire system
Input (AC)
Input range
App. Consumed VA
Voltage
Current
0.2VA
0.4VA
0.2VA
0.8VA
RP
110V/1A
110V/5A
220V/1A
220V/5A
440V/1A
440V/5A
100W
500W
200W
1000W
400W
2000W
-120 to +120W
-600 to +600W
-240 to +240W
-1200 to +1200W
-480 to +480W
-2400 to +2400W
•
1-phase 3-wire system
Input (AC)
Input range
App. Consumed VA
Voltage
Current
0.2VA/
phase
0.2VA/
phase
RP
200V/1A
200V/5A
200W
1000W
-240 to +240W
-1200 to +1200W
•
3-phase 3-wire system
Input (AC)
Input range
App. Consumed VA
Voltage
Current
0.2VA/
phase
0.4VA/
phase
0.2VA/
phase
0.8VA/
phase
RP
110V/1A
110V/5A
220V/1A
220V/5A
440V/1A
440V/5A
200W
1000W
400W
2000W
800W
4000W
-240 to +240W
-1200 to +1200W
-480 to +480W
-2400 to +2400W
-960 to +960W
-4800 to +4800W
•
3-phase 4-wire system
Input (AC)
Input range
App. Consumed VA
Voltage
Current
0.2VA/
phase
RP=Rated Power
0.4VA/
phase
0.1VA/
phase
0.2VA/
phase
0.2VA/
phase
0.5VA/
phase
RP
110V/1A
110V/5A
220V/1A
220V/5A
64V/1A
64V/5A
127V/1A
127V/5A
277V/1A
277V/5A
300W
1500W
600W
3000W
200W
1000W
400W
2000W
800W
4000W
-360 to +360W
-1800 to +1800W
-720 to +720W
-3600 to +3600W
-240 to +240W
-1200 to +1200W
-480 to +480W
-2400 to +2400W
-960 to +960W
-4800 to +4800W