background image

6

IM 701988-01E

General Specifications

Standard operating 

conditions

Temperature 

23±5°C

Humidity

4

55 ±10% RH

Operating 

environment

Temperature

5 to 40°C

Humidity

4

20 to 80% RH

Altitude

2000 m or less

Storage environment Temperature

−20 to 60°C

Humidity

4

20 to 80% RH

Altitude

3000 m or less

Interface and power supply

Dedicated logic probe interface

Power supplied from a dedicated logic probe 

interface

Calibration cycle

1 year

Warm-up time

30 minutes or more

Ext. dimensions (main body)

94.5 mm × 40 mm × 15 mm

Total length

Approximately 1.8 m

Weight

Approximately 180 g (excluding accessories)

4.  No condensation

Standards Compliance

EMC 

standards

Emissions Conforming standards

EN61326-1 ClassA

EN55011 Class A Group1

EMC standards of Australia and New Zealand EN55011 

Class A, Group1

Korea Electromagnetic Conformity Standard (

한국 

전자파적합성기준

)

This is a Class A product. Operation of this product in a 

residential area may cause electromagnetic interference 

in which case the user will be required to correct the 

interference.

Immunity

Conforming standard

EN61326-1 Table 2 (for use in industrial locations)

Influence in the immunity testing environment

The logic probe’s polarity must not reverse

5

Environmental 

standards

6

EU RoHS Directive compliant

5.  Test conditions
  Connected to the DLM2000 series mixed signal oscilloscope, with the logic probe’s 

lead set terminated at 50 Ω. 

Cable condition
  Attach a ferrite core (TDK: ZCAT2035-0930A, YOKOGAWA part number: 

A1190MN) to both ends of the cable (see figure below). 

 

 

    

6  For conformity to environmental regulations and/or standards other than EU, 

contact your nearest YOKOGAWA office (PIM113-01Z2)

Содержание PBL100

Страница 1: ...User s Manual Model 701988 PBL100 Logic Probe IM 701988 01E 6th Edition...

Страница 2: ...provided on the following sheet Document No Description PIM 113 01Z2 List of worldwide contacts Notes The contents of this manual are subject to change without prior notice as a result of continuing...

Страница 3: ...be taken to prevent such occurrences CAUTION Calls attention to actions or conditions that could cause light injury to the user or damage to the instrument or user s data and precautions that can be...

Страница 4: ...6 7 8 9 1 2 3 4 5 6 7 PBL100 Logic Probe Name Qty Part Number 1 Logic probe 1 2 Probe lead set 1 B8099BS 3 Cable 1 5 m 1 B9852VN Standard Accessories Name Qty Part Number 4 Microclips black set of 2 1...

Страница 5: ...sation et d entretien Ce symbole a t appos aux endroits dangereux de l instrument pour lesquels des consignes sp ciales d utilisation ou de manipulation ont t mises Le m me symbole appara t l endroit...

Страница 6: ...er bend the cable to a radius of less than 60 mm Never apply force to a small part of the cable nor deform the cable Never twist or pull the probe leads or GND lead any more than necessary The wires i...

Страница 7: ...z inflammables Pour viter toute blessure et incendie n utilisez pas la sonde proximit de gaz ou de vapeurs inflammables ou explosifs vitez les circuits expos s Pour viter toute blessure lorsque l appa...

Страница 8: ...iles Si des probl mes sont d tect s veuillez contacter votre revendeur ou repr sentant YOKOGAWA le plus proche Cet instrument n est pas tanche aux gouttes d eau ou la poussi re Ne l utilisez pas dans...

Страница 9: ...stic household waste When disposing of products in the EEA or UK contact your local Yokogawa office in the EEA or UK respectively EEA European Economic Area Authorized Representative in the EEA Yokoga...

Страница 10: ...i Checking the Contents of the Package iii Safety Precautions iv Regulations and Sales in Various Countries and Regions viii Overview 1 Names and Functions of Parts 2 Usage Precautions 3 Operating Pr...

Страница 11: ...re compatible with this instrument please contact your nearest YOKOGAWA representative Features High input impedance 1 M 10 pF each input terminal to ground Wide input voltage range 40 V Supports 2 54...

Страница 12: ...ion to the circuit under test consisting of 8 probe leads and 2 GND leads Probe Leads The points of connection to the circuit under test Can be directly connected to 2 54 mm pitch pin headers GND Lead...

Страница 13: ...le jeu de fils de la sonde est retir et remplac par un autre destin un autre mod le d instrument Lors du nettoyage utilisez un chiffon doux et veillez ne pas endommager la sonde De plus n immergez jam...

Страница 14: ...4 IM 701988 01E Usage Example Probe Lead Set 2 54 mm Pitch Pin Header Probe Lead Set Microclips...

Страница 15: ...Input voltage range 40 V Min input voltage2 500 mVp p Hysteresis voltage 100 mV typical 3 Input impedance 1 M 10 pF typical 3 Maximum toggle frequency2 100 MHz or more Min pulse width2 5 ns 1 See dera...

Страница 16: ...Group1 EMC standards of Australia and New Zealand EN55011 Class A Group1 Korea Electromagnetic Conformity Standard This is a Class A product Operation of this product in a residential area may cause...

Страница 17: ...ecome damaged Please use the following components Name Part Number Probe lead set B8099BS Cable 1 5 m B9852VN Replacing the Probe Lead Set Remove the probe lead set from the logic probe then align the...

Отзывы: