background image

6

IM 77J01P08-01E

6th Edition

Measurement 

category

Description

Remarks

O

(other) For measurements 

performed on circuits not 

directly connected to MAINS.

II

CAT.II For measurements 

performed on circuits directly 

connected to the low-voltage 

installation.

Appliances, 

portable 

equipments, 

etc.

III

CAT.III For measurements 

performed in the building 

installation.

Distribution 

board, circuit 

breaker, etc.

IV

CAT.IV For measurements 

performed at the source of 

the low-voltage installation.

Overhead 

wire, cable 

systems, etc.

EMC standards:

CE:

EN 61326-1 Class A, Table 2

EN 61326-2-3

* The instrument continues to operate at a measurement 

accuracy of within ±20% of the range during testing.

EN 55011 Class A, Group 1

EN 61000-3-2

EN 61000-3-3

RCM: 

EN 55011 Class A, Group 1

KC:

Electromagnetic wave interference prevention standard, 

electromagnetic wave protection standard

 CAUTION

Caution to comply with EMC standards: When 

operating this instrument by external power supply, 

use an independent power unit conforming to CE-

marking. Be sure to use the lightning arrester to 

comply EMC standards.

Note:  When option code /C0 or /FB is specified, the 

conformity to the safety and EMC standards is 

excluded.

Note:  When contactless AC switch is specified for the 

output-1 signal code or output-2 signal code, it will not 

comply with safety and EMC standards.

9.  ENVIRONMENT STANDARD

EU RoHS directive: EN IEC 63000

  (However, when contactless AC switch is specified for the 

output signal, and suffix code /C0 or /FB is specified, CE 

marking is not applicable because the product does not 

conform to safety and EMC standards.)

10.  TRANSPORT AND STORAGE CONDITIONS

 •

Temperature: −25 to 70°C

 •

Temperature change rate: 20°C per hour or less

 •

Humidity: 5 to 95%RH (no condensation)

 CAUTION

Keep this product in a conductive bag when plugged 

out, during transport or storage.

Отзывы: