background image

User’s

Manual

IS8000

Integrated Software

High-speed Camera Synchronization 

Feature (FS1 option)

IM IS8000-61EN

7th Edition

Содержание IS8000

Страница 1: ...User s Manual IS8000 Integrated Software High speed Camera Synchronization Feature FS1 option IM IS8000 61EN 7th Edition ...

Страница 2: ...s performance and functionality Refer to our website to view our latest manuals The figures given in this manual may differ from those that actually appear on your screen Every effort has been made in the preparation of this manual to ensure the accuracy of its contents However should you have any questions or find any errors please contact your nearest YOKOGAWA dealer Copying or reproducing all o...

Страница 3: ...ii IM IS8000 61EN Revisions 1st Edition March 2021 2nd Edition July 2021 3rd Edition September 2021 4th Edition January 2022 5th Edition March 2022 6th Edition June 2022 7th Edition August 2022 ...

Страница 4: ...ample 100 kS s sample rate K Denotes 1024 Example 720 KB file size Displayed Characters Bold alphanumeric characters in procedural explanations indicate characters that appear in the menus on the screen Notes This manual uses the following symbol to indicate notes Note Calls attention to information that is important for the proper operation of the software ...

Страница 5: ...Check the following information If the wrong items have been delivered or if items are missing contact your nearest YOKOGAWA dealer Inquiries PIM 113 01Z2 1 sheet Product Information PI IS8000 01 1 sheet Product Information The following items are indicated Please keep this sheet in a safe place Model IS8001EX or IS8002EX and suffix code FS1 of this option License code You need to enter this licen...

Страница 6: ... a measuring instrument It is not possible to connect to the same measuring instrument from multiple PCs at the same time When you connect a measuring instrument to a PC and use this option to control the instrument you cannot use multiple types of communication interface at the same time Do not perform panel operations on the measuring instrument while data is being recorded The option may not be...

Страница 7: ......

Страница 8: ... IS8000 2 2 2 3 Configuring the Camera 2 3 2 4 Synchronizing the Camera to the DL950 2 4 2 5 Recording and Saving Videos and Waveforms 2 5 Chapter 3 Displaying Saved Videos and Waveforms 3 1 Loading Video Data and Waveform Data 3 1 3 2 Controlling the Video Display 3 2 Chapter 4 Offline Synchronization of Videos and Waveforms 4 1 Loading Video Data and Waveform Data 4 1 4 2 Setting the Synchroniza...

Страница 9: ...orms measured by a waveform measuring instrument and video shot by a high speed camera in sync based on triggers and enables analysis of the data The trigger signal and sample clock generated by the measuring instrument is applied to the high speed camera The waveforms and video are displayed in sync on a PC monitor by loading the measured waveform data and the high speed camera s video and shooti...

Страница 10: ...utputs a trigger signal to the camera The camera records video and shooting information before and after this trigger output Saved Range Range of Saved Waveform Data The range of waveform data that is saved is the recording time T div 10 of the DL950 measurement instrument the range between points A and B Set this longer than the video to be saved For details on the number of waveform data points ...

Страница 11: ...nect the DL950 s sync signal and trigger signal to the appropriate input terminals or connectors of the camera DL950 s left side panel Camera Sample clock output terminal CLKO screwless terminal block Trigger output terminal TRIGGER OUT BNC connector To the sync signal input terminal To the trigger signal input terminal Connect to the PC via Ethernet or USB Connect to the PC via Ethernet ...

Страница 12: ...h speed camera When the high speed camera is connected to the Internet add IS8000 exe in the IS8000 installation folder as an exception to the Windows Firewall 5 Click Search In the list of detected devices select the check boxes for the DL950 and high speed camera and then click Open or Next If you click Next a window such as Channel Setting and DAQ Setting will appear Specify the settings see Ch...

Страница 13: ...amera The camera settings appear 4 Click the camera setting boxes and select or set the values You will specify the settings required for synchronization in the Sync Setting window on the next page Those settings are applied to the Device Control settings Shows or hides the Device Control panel Shows or hides the Overview panel The DL950 and camera are synchronized When you set Devices to the came...

Страница 14: ...and the number of recorded frames specified on the camera 3 Check the DL950 settings and then click Confirm Sync Setting window Apply Camera settings DL950 settings Confirm Number of pre trigger frames Fnb fps Sync signal from the DL950 Trigger signal from the DL950 The camera synchronized to the DL950 is displayed Number of post trigger frames Fna fps Number of recorded frames Fn Fnb Fna fps Reco...

Страница 15: ...DAQ Setting window will appear Here you can set the save destination file name and so on for saving the contents in step 2 By default C Users user name Documents YOKOGAWA IS8000 is selected 2 Click Stop The recorded video and acquired waveform data are saved automatically If you stop saving in the middle of the operation you can click Save Video on the Video tab to carry out the save operation aga...

Страница 16: ...es or they may not work entirely Start Hold Rec Stop File Divide When recording is performed multiple times in sync with external triggers Record Count of 2 or more video may not be recorded if the external trigger interval is less than approximately 1500 ms If the data file of a video you want to shoot is greater than or equal to 4 GB recording cannot be started 2 5 Recording and Saving Videos an...

Страница 17: ...ion explained in section 2 5 3 From the folder you opened open a analysis project file anpjt The video data and waveform data corresponding to the selected project file are loaded and an Analysis file name tab window opens Even when the IS8000 is not running the IS8000 starts automatically and displays the analysis offline analysis tab window Project file The waveform data file and video data file...

Страница 18: ...of the video cursor on the waveform are synchronized During playback the video cursor and vertical cursor 1 are synchronized If you specify View1 to 4 under Video Follow of Video1 properties the video and zoom position are synchronized during playback Video tab Video1 Move to the first video frame Move to the previous video frame Reverse Play Stop Move to the next video frame Move to the last vide...

Страница 19: ...urce display area to open them For details on the procedures see the referenced sections in the User s Manual IM IS8000 01EN Drop a file section 4 1 Open multiple files section 4 1 Select a video data file and waveform data file and drop them under Waveform Files You can also load files in the following ways For details on the procedures see the referenced sections in the User s Manual IM IS8000 0...

Страница 20: ...S8000 01EN Video1 panel Overview panel Waveform file list When the Loaded File Is Not Synchronized When the tab window name is Analysis waveform file name and the video is not displayed 2 Select the video file loaded using Waveform Files and select Start Coaxial from the menu The tab window name is Analysis waveform file name Select a video data file and click and then Start Coaxial The Overview p...

Страница 21: ...m is displayed Proceed to step 3 When the loaded file is synchronized but the video is not displayed 3 On the Video tab click Video1 If two video files have been loaded and synchronized click also Video2 The Video1 and Video2 panels will open within the tab window and the videos and waveforms will be displayed synchronized Creating a Project File If necessary create an analysis project files anpjt...

Страница 22: ...channel from the drop down list Sync position Sync Position Specify the position of the synchronization waveform to align the start frame to You can select the following items from the drop down list Trigger position Trigger Position The start frame is aligned with the trigger position of the synchronization waveform First First The start frame is aligned with the beginning of the synchronization ...

Страница 23: ... Specify the number of frames per trigger at Video1 or Video2 properties Sync Number of Frames per Trigger The Recording Count trigger count value under Information is automatically corrected according to Total FrameNumber of Frames per Trigger fractions rounded up The trigger positions of the waveform and those of the video will be displayed synchronized Synchronization Position Relationship betw...

Страница 24: ...tem Specifications Video and waveform synchronous display Offline synchronous display of waveform data measured with a waveform measuring instrument and two video files Analysis project file storage If necessary manually save the analysis project file anpjt Display control of saved data Play reverse play stop video frame jump repeat play and play speed adjustment Supported video file formats AVI a...

Страница 25: ...5 2 IM IS8000 61EN 5 3 YOKOGAWA Measuring Instrument Supporting This Option MODEL Specifications DL950 An input module appropriate for the measurement target must be installed ...