![YOKOGAWA Dpharp vigilantplant EJA115 Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/yokogawa/dpharp-vigilantplant-eja115/dpharp-vigilantplant-eja115_user-manual_3674529066.webp)
IM 01C22K01-01E
10-3
10. GENERAL SPECIFICATIONS
10.2
Model and Suffix Codes
Model EJA115
[Style: S3]
. . . . . . . . . . . . . . . . . . . . . . .
-D . . . . . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . . . . . . . . . .
-F . . . . . . . . . . . . . . . . . . . . .
-G . . . . . . . . . . . . . . . . . . . . .
L . . . . . . . . . . . . . . . . . .
M . . . . . . . . . . . . . . . . . .
H . . . . . . . . . . . . . . . . . .
S . . . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . . .
4 . . . . . . . . . . . . . . . .
00 . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . .
B . . . . . . . . . . . . . .
-2 . . . . . . . . . . . .
-3 . . . . . . . . . . . .
-6 . . . . . . . . . . . .
-7 . . . . . . . . . . . .
-8 . . . . . . . . . . . .
-9 . . . . . . . . . . . .
0 . . . . . . . . . . . .
2 . . . . . . . . . . . .
3 . . . . . . . . . . . .
4 . . . . . . . . . . . .
5 . . . . . . . . . . . .
7 . . . . . . . . . . . .
8 . . . . . . . . . . . .
9 . . . . . . . . . . . .
D . . . . . . . . . .
E . . . . . . . . . .
N . . . . . . . . . .
A . . . . . . .
B . . . . . . .
C . . . . . . .
D . . . . . . .
N . . . . . . .
Model
Description
EJA115
Output Signal
Measurement span
(capsule)
Wetted parts material
Process flange rating
–
Bolts and nuts material
Installation
Electrical connection
Integral indicator
Mounting bracket
Optional codes
Low Flow transmitter
4 to 20 mA DC with digital communication (BRAIN protocol)
4 to 20 mA DC with digital communication (HART protocol)
(Note 1)
Digital communication (F
OUNDATION
Fieldbus protocol)
(Note 4)
Digital communication (PROFIBUS PA protocol)
(Note 5)
1 to 10 kPa {100 to 1000 mmH
2
O}
2 to 100 kPa {200 to 10000 mmH
2
O}
20 to 210 kPa {2000 to 21000 mmH
2
O}
[Body]
(Note 3)
[Capsule] [Orifice]
JIS SCS14A
JIS SUS316L
(Note 2)
JIS SUS316
Rc1/2 female
1/2 NPT female
Always 00
[Maximum working pressure]
(L capsule)
(M, H capsule)
JIS SCM435
3.5 MPa {35 kgf/cm
2
} 14 MPa {140 kgf/cm
2
}
JIS SUS630
3.5 MPa {35 kgf/cm
2
} 14 MPa {140 kgf/cm
2
}
Vertical impulse piping type, right side high pressure, manifold upside
Vertical impulse piping type, right side high pressure, manifold downside
Vertical impulse piping type, left side high pressure, manifold upside
Vertical impulse piping type, left side high pressure, manifold downside
Horizontal impulse piping type, right side high pressure
Horizontal impulse piping type, left side high pressure
G1/2 female, one electrical connection
1/2 NPT female, two electrical connections without blind plug
Pg 13.5 female, two electrical connections without blind plug
M20 female, two electrical connections without blind plug
G1/2 female, two electrical connections and a blind plug
1/2 NPT female, two electrical connections and a blind plug
Pg 13.5 female, two electrical connections and a blind plug
M20 female, two electrical connections and a blind plug
Digital indicator
Digital indicator with the range setting switch
(None)
JIS SECC
2-inch pipe mounting (flat type)
JIS SUS304 2-inch pipe mounting (flat type)
JIS SECC
2-inch pipe mounting (L type)
JIS SUS304 2-inch pipe mounting (L type)
(None)
/
Optional specification
Suffix Codes
T1004.EPS
Example: EJA115-DMS400A-92NN/
Note 1: Refer to IM 01C22T01-01E for HART Protocol version.
Note 2: Indicates other wetted parts materials. Diaphragm material is Hastelloy C-276.
Note 3: Indicates material of cover flanges and process connectors. Manifold and vent plugs material
are JIS SUS316.
Note 4: Refer to IM 01C22T02-01E for Fieldbus communication.
Note 5: Refer to IM 01C22T03-00E for PROFIBUS PA communication.