9. GENERAL SPECIFICATIONS
(See Table for Span and
Range Limits.)
Nitrogen(N
2
) Gas or Water
*11
Retention time: one minute
T0905.EPS
Amplifier cover only
Degrease cleansing treatment
Degrease cleansing treatment and with fluorinated oilfilled capsule.
Operating temperature – 20 to 80
°
C (– 4 to 176
°
F)
Fluorinated oil filled in capsule
P calibration (psi unit)
bar calibration (bar unit)
M calibration (kgf/cm
2
unit)
304 SST stainless steel tag plate wired onto transmitter
Data configuration for HART communication type
Software damping, Descriptor, Message
Data configuration for BRAIN communication type
Software damping
Process Connector
Test Pressure: 200 kPa (2 kgf/cm
2
)
*7
Test Pressure: 2 MPa (20 kgf/cm
2
)
*8
Test Pressure: 10 MPa (100 kgf/cm
2
)
*9
Test Pressure: 50 MPa (500 kgf/cm
2
)
*10
Failure alarm down-scale: Output status at CPU failure and hardware error is – 5%,
3.2mA DC or less.
Description
Amplifier cover and terminal cover, Munsell 7.5 R4/14
Anti-corrosion coating
*1
Transmitter power supply voltage: 10.5 to 32 V DC ( 10.5 to 30 V DC for intrinsically
safe type, 9 to 32 V DC for Fieldbus communication type.)
Allowable current: Max. 6000 A ( 1
40
s ), Repeating 1000 A ( 1
40
s ) 100 times
Applicable Standards: IEC 61000-4-4, IEC 61000-4-5
Color change
Coating change
Painting
Code
P
PR
X2
K1
K2
K3
D1
D3
D4
CA
CB
M15
T05
T06
T07
T08
N4
C1
C2
C3
A
Item
NAMUR NE43 Compliant
Output signal limits: 3.8mA to
20.5 mA
Failure alarm down-scale: Output status at CPU
failure and hardware error is – 5%, 3.2mA DC or less.
Failure alarm up-scale: Output status at CPU
failure and hardware error is 110%, 21.6 mA or more.
Lightning protector
Oil-prohibited use
Transistor output (sink type)
Rating: 10.5 to 30 V DC, 120 mA DC (max)
Low level: 0 to 2 V DC
AL
Status output *
2
Capsule fill fluid
Calibration units
*3
Output limits
and failure operation
*4
Stainless steel tag plate
Data Configuration at factory
*5
Material Certificate
*6
Pressure test
/Leak test Certificate
European Pressure Equipment
Directive*
12
PED 97/23/EC
Category III, Module H, Type of Equipment: Pressure Accessory-Vessel,
Type of Fluid: Liquid and Gas, Group of Fluid: 1 and 2
PE3
*1: Not applicable with color change option.
*2: Check/External indicator terminals cannot be used when this option code is specified. Not applicable for output signal code
F
and
amplifier housing code
2
.
*3: The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes
D1, D3,
and
D4.
*4: Applicable for output signal codes
D
and
E
. The hardware error indicates faulty amplifier or capsule.
*5: Also see ‘Ordering Information’.
*6: Material traceability certification, per EN 10204 3.1B.
*7: Applicable for capsule code
A
.
*8: Applicable for capsule code
B
.
*9: Applicable for capsule code
C
.
*10: Applicable for capsule code
D
.
*11: Pure nitrogen gas or pure water is used for oil-prohibited use (option codes
K1
and
K2
).
*12: Applicable for measurement span code
D
. If compliance with category III is needed, specify this option code.