IM 01C25C01-01E
9-2
9. GENERAL SPECIFICATIONS
2.7 (0.38)
100 (14.5)
1 (0.14)
10 (1.4)
–50
(–58)
0
(32)
50
(122)
100
(212)
150
(302)
200
(392)
250
(482)
300
(572)
F0901.EPS
Process temperature
for fill fluid code B
Process temperature
for fill fluid code A
Flange max.
working
pressure
Atmospheric
pressure
Transmitter ambient
temperature range
(for fill fluid code B)
Process Temperature
C (
°
F)
Working
pressure
kPa abs
(psi abs)
Figure 9.1
Working Pressure and Process Temperature
(Fill fluid: silicone oil for general and high
temperature use )
Supply & Load Requirements “
”
(Optional features or approval codes may affect
electrical requirements.)
With 24 V DC supply, up to a 550
load can be used. See
graph below.
E-10.5
0.0244
(
)
Power supply voltage E (V DC)
600
250
R
10.5
16.6
25.2
42
External
load
resistance
Digital
Communication
range
BRAIN and HART
R=
F0902.EPS
Figure 9.2
Relationship Between Power Supply Voltage
and External Load Resistance
Supply Voltage
10.5 to 42 V DC for general use and flameproof type.
10.5 to 32 V DC for lightning protector (Option code /A).
10.5 to 30 V DC for intrinsically safe, type n or non-
incendive type.
Minimum voltage limited at 16.6 V DC for digital
communications, BRAIN and HART
Load (Output signal code D and E)
0 to 1290
for operation
250 to 600
for digital communication
Communication Requirements “
”
(Safety approvals may affect electrical require-
ments.)
BRAIN
Communication Distance
Up to 2 km (1.25 miles) when using CEV polyethylene-
insulated PVC-sheathed cables. Communication distance
varies depending on type of cable used.
Load Capacitance
0.22
F or less
Load Inductance
3.3 mH or less
Input Impedance of communicating device
10 k
or more at 2.4 kHz.
HART
Communication Distance
Up to 1.5 km {1 mile} when using multiple twisted pair
cables. Communication distance varies depending on type
of cable used.
Use the following formula to determine cable length for
specific applications:
L= –
65
10
6
(R
C)
(C
f
+ 10,000)
C
Where:
L = length in meters or feet
R = resistance in
(including barrier resistance)
C = cable capacitance in pF/m or pF/ft
C
f
= maximum shunt capacitance of receiving devices in
pF/m or pF/ft
EMC Conformity Standards
,
EN 61326, AS/NZS 2064