5-275
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
:TRIGger{[:ATRigger]|:BTRigger}:I2C:
NONack:STARtbyte
Function
Sets or queries whether or not NON ACK will be
ignored in start bytes for I
2
C bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:I2C:
NONack:STARtbyte {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:I2C:
NONack:STARtbyte?
Example
:TRIGGER:ATRIGGER:I2C:NONACK:STARTBY
TE ON
:TRIGGER:ATRIGGER:I2C:NONACK:STARTBY
TE?
-> :TRIGGER:ATRIGGER:I2C:NONACK:STAR
TBYTE 1
:TRIGger{[:ATRigger]|:BTRigger}:I2C:
SCL
Function
Sets or queries the clock signal for I
2
C bus signal
triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:I2C:
SCL {<NRf>|PODA<x>|PODB<x>|PODL<x>}
:TRIGger{[:ATRigger]|:BTRigger}:I2C:
SCL?
<NRf> = 1 to 8
<x> of PODA<x>, PODB<x>, PODL<x> = 0 to 7
Example
:TRIGGER:ATRIGGER:I2C:SCL 1
:TRIGGER:ATRIGGER:I2C:SCL?
-> :TRIGGER:ATRIGGER:I2C:SCL 1
:TRIGger{[:ATRigger]|:BTRigger}:I2C:
SDA
Function
Sets or queries the data signal for I
2
C bus signal
triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:I2C:
SDA {<NRf>|PODA<x>|PODB<x>|PODL<x>}
:TRIGger{[:ATRigger]|:BTRigger}:I2C:
SDA?
<NRf> = 1 to 8
<x> of PODA<x>, PODB<x>, PODL<x> = 0 to 7
Example
:TRIGGER:ATRIGGER:I2C:SDA 1
:TRIGGER:ATRIGGER:I2C:SDA?
-> :TRIGGER:ATRIGGER:I2C:SDA 1
Description The data signal that you can specify varies
depending on the "
:
TRIGger{[:ATRigger]|:
BTRigger}:I2C:SCL
" setting.
For details, see the DLM4000 User’s Manual.
:TRIGger{[:ATRigger]|:BTRigger}:LIN?
Function
Queries all LIN bus signal trigger settings.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN?
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
BLENgth
Function
Sets or queries the LIN bus signal trigger break
length.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
BLENgth {<NRf>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
BLENgth?
<NRf> = 10 to 13
Example
:TRIGGER:ATRIGGER:LIN:BLENGTH 10
:TRIGGER:ATRIGGER:LIN:BLENGTH?
-> :TRIGGER:ATRIGGER:LIN:BLENGTH 10
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
BRATe
Function
Sets or queries the LIN bus signal trigger bit rate
(data transfer rate).
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
BRATe {<NRf>|USER,<NRf>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
BRATe?
<NRf> = 1200, 2400, 4800, 9600, 19200
USER <NRf> = See the DLM4000 Feature Guide
for this information.
Example
:TRIGGER:ATRIGGER:LIN:BRATE 2400
:TRIGGER:ATRIGGER:LIN:BRATE?
-> :TRIGGER:ATRIGGER:LIN:BRATE 2400
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
ERRor?
Function
Queries all LIN bus signal trigger error settings.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
ERRor?
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
ERRor:PARity
Function
Sets or queries the LIN bus signal trigger parity
error setting.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
ERRor:PARity {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:LIN:
ERRor:PARity?
Example
:TRIGGER:ATRIGGER:LIN:ERROR:PARI
TY ON
:TRIGGER:ATRIGGER:LIN:ERROR:PARITY?
-> :TRIGGER:ATRIGGER:LIN:ERROR:PARI
TY 1
5.34 TRIGger Group