YOKOGAWA Centum ANT421 Скачать руководство пользователя страница 7

7

<<Contents>>  <<Index>>

All Rights Reserved. Copyright © 2015, Yokogawa Electric Corporation

GS 33J60F55-01EN

l

 Example of Chain Type Connection 

In the case of FCU(for FIO) (*2)

F05E.ai

: Multimode optical fiber

Max. length of

Fiber-optic cable 4 km

ANT421: + A2EE2A-T  (Connector unit 

    with terminator for ESB Bus)

ANT522: + A2EE3A-TH (Connector unit with 

    terminator for ESB Bus, With HKU I/F)

ANT421: + A2EE2A-T  (Connector unit 

    with terminator for ESB Bus)

ANT522: + A2EE3A-NH  (Connector unit 

    for ESB Bus, With HKU I/F)

Max. length of

Fiber-optic cable 4 km

Total Max. length of

Fiber-optic cable 8 km

Optical ESB Bus Node Unit 

Optical ESB Bus Node Unit 

FCU (for FIO)

I

O

M

I

O

M

I

O

M

I

O

M

I

O

M

I

O

M

I

O

M

I

O

M

P

S

U

P

S

U

I

O

M

I

O

M

I

O

M

I

O

M

I

O

M

I

O

M

P

S

U

P

S

U

I

O

M

I

O

M

I

O

M

I

O

M

A

N

T

4

2

1

A

N

T

4

2

1

A

N

T

4

2

1

A

N

T

5

2

2

A

N

T

5

2

2

A

N

T

5

2

2

A

N

T

5

2

2

A

N

T

4

2

1

E

C

4

0

1

E

C

4

0

1

P

S

U

P

S

U

C

P

4

6

1

or

C

P

4

7

1

C

P

4

6

1

or

C

P

4

7

1

HKU

HKU

HKU

UTILITY UNIT

(*1)(*1)

*1: 

A dual-redundant configuration is enabled by using 2 identical modules with same model code (CP461 or CP471).

*2:   For detail about FCU, refer to “FIO System Overview” (GS 33J60A10-01EN).

Figure  Example of Chain Connection Using HK Function

Jan. 22, 2021-00

Содержание Centum ANT421

Страница 1: ...the temperatures and fans in the cabinet specify With HKU interface A2EE3A H The ESB Bus Adapter A2EE3A should be ordered separately l Installation Position The following table shows the units and num...

Страница 2: ...connection FCU for N IO 16 hops for chain and star connection 2 FCU for RIO System Upgrade 8 hops for chain and star connection Maximum transmission distance 3 4 km one hop Optical connector type LC...

Страница 3: ...iber cable specifications Maximum permissible optical loss 0 to 7 dB 1 3 m 1 Optical Fiber Type Quartz multimode fiber GI 50 125 2 GI 62 5 125 3 Transmission bandwidth Up to 2 km transmission distance...

Страница 4: ...129 130 Unit mm F02E ai A2EE2A N Connector unit for ESB Bus A2EE2A T Connector unit with terminator for ESB Bus IN OUT OPT CN2 CN1 IN OUT OPT CN1 Nominal tolerances Nominal tolerance is 0 8 mm for the...

Страница 5: ...side ANT522 as described below ANT421 for master side and ANT522 for slave side ANT421 for master side and A2EN501 for slave side A2EN501 for master side and ANT522 for slave side Dual redundant modu...

Страница 6: ...4 km or less Optical ESB Bus Node Unit for dual redundant Optical ESB Bus A L F 1 1 1 A L F 1 1 1 A L R 1 2 1 A L R 1 2 1 A N T 5 2 2 A N T 5 2 2 Optical ESB Bus Node Unit for dual redundant Optical...

Страница 7: ...tic cable 4 km Total Max length of Fiber optic cable 8 km Optical ESB Bus Node Unit Optical ESB Bus Node Unit FCU for FIO I O M I O M I O M I O M I O M I O M I O M I O M P S U P S U I O M I O M I O M...

Страница 8: ...P S U E C 4 0 1 E C 4 0 1 C P 4 6 1 or C P 4 7 1 C P 4 6 1 or C P 4 7 1 1 1 Optical ESB Bus Repeater Unit P S U P S U A N T 4 1 1 A N T 4 1 1 A N T 4 0 1 A N T 4 0 1 Optical ESB Bus Node Unit I O M I...

Страница 9: ...Optical ESB Bus Repeater Slave Module for Multimode Fiber Description Model ANT522 Optical ESB Bus Repeater Slave Module 4 km for Multimode Fiber Suffix Codes 5 Standard type with no explosion protec...

Страница 10: ...t to be installed needs to be specified 4 Select the option code ATDOC to follow the ATEX Directive and UKEX Regulation for use in potentially explosive atmospheres Node Unit for Dual Redundant ESB Bu...

Страница 11: ...ew GS 33J01A10 01EN n ORDERING INFORMATION Specify the model and suffix codes and option codes when ordering For selecting the right products for explosion protection please refer to TI 33J01J30 01EN...

Отзывы: