n

 EXAMPLE OF CONNECTION STRUCTURE

l

 Example of Chain and Star Connection 

In the case of FCU (for N-IO) or FCU (for RIO System Upgrade) (*2)

TM1

READY

 FUSE RL1 

CN1 (PSU-L)

TM2    100-120V    AC

CN2 (PSU-R)

EC401

EC401

ANT421

ANT421

ANT421

ANT421

ANT421

ANT421

Optical ESB Bus Node Unit 

(for dual-redundant Optical ESB Bus)

ALF111

ALF111

ALR121

ALR121

ANT522

ANT522

Optical ESB Bus Node Unit 

(for dual-redundant Optical ESB Bus)

ALF111

ALF111

ALR121

ALR121

ANT522

ANT522

N-IO

A2EN501

A2PW50

A2PW50

A2EN501

A2NN

0D (*1)

N-IO

A2EN501

A2PW50

A2PW50

A2EN501

A2NN

0D (*1)

ANT421

IO1, 2

: 

+ A2EE2A-T  (Connector unit with 

  

terminator for ESB Bus)

ANT421

IO3, 4

: 

+ A2EE2A-N  (Connector unit for ESB Bus)

ANT421

IO5, 6

 + A2EE2A-N  (Connector unit for ESB Bus)

FCU 

(for N-IO / for RIO System Upgrade)

Max. length of 

optical cable

 4 km or less

ANT522: + A2EE3A-TN (Connector unit with 

terminator for ESB Bus)

ANT522:  + A2EE3A-TN (Connector unit with 

 

terminator for ESB Bus)

Max. length of

optical cable

4 km or less

Optical ESB Bus Node Unit 

(for dual-redundant Optical ESB Bus)

ALF111

ALF111

ALR121

ALR121

ANT522

ANT522

Optical ESB Bus Node Unit 

(for dual-redundant Optical ESB Bus)

ALF111

ALF111

ALR121

ALR121

ANT522

ANT522

ANT421

ANT421

ANT522: + A2EE3A-TN (Connector unit with terminator for ESB Bus)

ANT522

: 

+ A2EE3A-NN (Connector unit for ESB Bus)

ANT421

: 

+ A2EE2A-T  (Connector unit with terminator for ESB Bus)

Total max. 

length of optical cable; 

8 km or less 

F04E.ai

N-IO node

N-IO node

Total max. 

length of optical cable; 

8 km or less

Max. length of

optical cable

4 km or less

Max. length of

optical cable

4 km or less

Max. length of

optical cable

4 km or less

Total max. 

length of optical cable; 

8 km or less

Max. length of

optical cable 4 km or less

A2EN501:

 

optical ESB bus (0

5 km)

 for uplink

optical ESB bus ((0

5 km)

 for downlink

A2EN501-S11



0

A2EN501: optical ESB bus (0

5 km)

 for uplink

optical ESB bus (0

5 km)

 for downlink

A2EN501-S11



0

*1: 

Connectable Node Interface Unit 

 

A2NN30D for FCU (for N-IO) 

 

A2NN10D or A2NN20D for FCU (for RIO System Upgrade)

*2: 

For detail about each FCU, refer to  “N-IO System Overview” (GS 33J62A10-01EN), and “Field Control Unit, Cabinet Utility 

Kit (for RIO System Upgrade)” (GS 33J64E10-01EN) 

Figure  Example of Chain and Star Connection (In the case of FCU for N-IO or FCU for RIO System Upgrade)

Aug. 6, 2021-00

Содержание Centum ANT421

Страница 1: ...the temperatures and fans in the cabinet specify With HKU interface A2EE3A H The ESB Bus Adapter A2EE3A should be ordered separately l Installation Position The following table shows the units and num...

Страница 2: ...connection FCU for N IO 16 hops for chain and star connection 2 FCU for RIO System Upgrade 8 hops for chain and star connection Maximum transmission distance 3 4 km one hop Optical connector type LC...

Страница 3: ...iber cable specifications Maximum permissible optical loss 0 to 7 dB 1 3 m 1 Optical Fiber Type Quartz multimode fiber GI 50 125 2 GI 62 5 125 3 Transmission bandwidth Up to 2 km transmission distance...

Страница 4: ...129 130 Unit mm F02E ai A2EE2A N Connector unit for ESB Bus A2EE2A T Connector unit with terminator for ESB Bus IN OUT OPT CN2 CN1 IN OUT OPT CN1 Nominal tolerances Nominal tolerance is 0 8 mm for the...

Страница 5: ...side ANT522 as described below ANT421 for master side and ANT522 for slave side ANT421 for master side and A2EN501 for slave side A2EN501 for master side and ANT522 for slave side Dual redundant modu...

Страница 6: ...4 km or less Optical ESB Bus Node Unit for dual redundant Optical ESB Bus A L F 1 1 1 A L F 1 1 1 A L R 1 2 1 A L R 1 2 1 A N T 5 2 2 A N T 5 2 2 Optical ESB Bus Node Unit for dual redundant Optical...

Страница 7: ...tic cable 4 km Total Max length of Fiber optic cable 8 km Optical ESB Bus Node Unit Optical ESB Bus Node Unit FCU for FIO I O M I O M I O M I O M I O M I O M I O M I O M P S U P S U I O M I O M I O M...

Страница 8: ...P S U E C 4 0 1 E C 4 0 1 C P 4 6 1 or C P 4 7 1 C P 4 6 1 or C P 4 7 1 1 1 Optical ESB Bus Repeater Unit P S U P S U A N T 4 1 1 A N T 4 1 1 A N T 4 0 1 A N T 4 0 1 Optical ESB Bus Node Unit I O M I...

Страница 9: ...Optical ESB Bus Repeater Slave Module for Multimode Fiber Description Model ANT522 Optical ESB Bus Repeater Slave Module 4 km for Multimode Fiber Suffix Codes 5 Standard type with no explosion protec...

Страница 10: ...t to be installed needs to be specified 4 Select the option code ATDOC to follow the ATEX Directive and UKEX Regulation for use in potentially explosive atmospheres Node Unit for Dual Redundant ESB Bu...

Страница 11: ...ew GS 33J01A10 01EN n ORDERING INFORMATION Specify the model and suffix codes and option codes when ordering For selecting the right products for explosion protection please refer to TI 33J01J30 01EN...

Отзывы: