IM 01E20D01-01E
6-30
6. OUTLINE
䊉
Table of Optional Specifications (continued)
Standard
⫹
90-degree rotation
⫹
180-degree rotation
⫺
90-degree rotation
Optional Code RC
Optional Code RA
Optional Code RB
Integral Flowmeter
Remote Flowtube
Electrical
Connection
Indicator
Electrical
Connection
Indicator
Electrical
Connection
Electrical
Connection
T26-4_1.EPS
*1:
*2: When specifying the optional code BCC or BSC for a PFA or ceramics lining, it is advisable to specify the optional code GA, GC, or GD at the same time to prevent
potential leakage caused by the difference in elasticity between the flowtube and chloroprene gaskets. Refer to description of “Gasket” in the “Wetted Part Material”.
*3: Allowable temperature and pressure with the optional code BCC or BSC (only for Gaskets:Chloroprene rubber) are equivalent to Valqua #2010.
*4: Allowable temperature and pressure with the optional code BCF or BSF (only for Gaskets:PTFE-sheathed non-asbestos) are equivalent to Valqua #7030 (S).
*5: Special gaskets are inserted between the flowtube and the grounding ring or grounding electrode.
*6: Enhanced dual frequency excitation is not available for models with calibration code C (High Grade Accuracy).
*7: Select optional code G12 or G11 when TIIS Flameproof type with wiring using a flameproof packing adapter. Available only for JIS G1/2 female electric connection.
*8: The TIIS flameproof type is only available for AXF***C-P (remote flowtube for combined use with AXFA14).
*9: In the case of Fieldbus communication type, optional codes C1, C2, C3, EM and G11 are not available.
*10:In the case of size 32 mm, optional code GH is not available.
*11:Neither optional code WT1 nor WT2 is available for models with lining material "Natural Soft Rubber" or "EPDM Rubber" (Lining code: D or G).
*12:Either optional code WT1 or WT2 can be selected.
*13:In case of sanitary type or union joint type with ceramics lining, optional code PM1, PM2 or PM3 is not available as they have no grounding rings.
*14:In case of carbon steel flanges or mini flanges, the amount of Nickel, Chromium and Molybdenum in the carbon steel are not stipulated and optional code PM2 or PM3 is not
available. For material specifications, refer to description of "Flowtube Material".
*15:Only one code from PM1, PM2 or PM3 can be selected.
*16:In case of no welded portion, optional code PT is not available. For available sizes, refer to the following table.
Size
Use
Process Connection
General-purpose Use
Submersible Type
Explosion proof Type
Wafer
Sanitary Type
Flange
Clamp/Union/Butt Weld Connection
25 to 300 mm (1.0 to 12 in.)
Note: Not available for size 25 mm (1.0 in.) with lay length of AXF Standard (Lay Length code: 1)
25 to 400mm (1.0 to 16 in.)
32 to 125 mm (1.25 to 5.0 in.)