68
IM AQ1210-02EN
AQ1215F, AQ1216F
Item
Specifications
AQ1215F
AQ1216F
Center wavelength
1310 nm ± 25 nm
1550 nm ± 25 nm
1650 nm ± 5 nm
1310 nm ± 25 nm
1550 nm ± 25 nm
1650 nm ± 25 nm
Event dead zone
1
0.7 m (1310 nm)
0.7 m (1550 nm)
0.7 m (1650 nm)
0.7 m (1310 nm)
0.7 m (1550 nm)
0.7 m (1650 nm)
Attenuation dead zone
2
2.5 m (typical value)
3
2.5 m (typical value)
3
Dynamic range
40 dB (1310 nm)
38 dB (1550 nm)
35 dB (1650 nm)
40 dB (1310 nm)
38 dB (1550 nm)
38 dB (1650 nm)
Loss measurement accuracy
±0.03 dB/dB
±0.03 dB/dB
Sampling resolution
2 cm (min.)
2 cm (min.)
Number of sampling points
256000 (max.)
256000 (max.)
Distance range
0.1 km to 512 km
0.1 km to 512 km
Pulse width
3 ns to 200 µs
3 ns to 20 µs
Return loss measurement accuracy ±2 dB
±2 dB
Distance measurement accuracy
± (1 m + measured distance × 2 × 10
–5
± 1 sampling resolution)
Compliant fiber
SM (ITU-T G.652)
SM (ITU-T G.652)
1 3 ns pulse width, 55 dB or more return loss, at a point at 1.5 dB or less from the peak value under unsaturated conditions
2 10 ns pulse width, 55 dB or more return loss, point where the backscattering light level is attenuated to a value within the regular value ± 0.5 dB
3 Typical values (typ.) are typical or mean values. They are not strictly warranted.
Power Checker (/PC option)
Item
Specification
Wavelength setting
1310 nm, 1490 nm, 1550 nm, 1625 nm, 1650 nm
Power range
–50 dBm to –5 dBm
Measurement accuracy (dB)
1
±0.5 dB
Optical input port
OTDR port (PORT1)
Specifications