<2. Receiving and Storage>
4
IM 01E21A01-03EN-A
2.
Receiving and Storage
When the product is delivered, check visually that no
damage has occurred during transportation. Also check that
all flowmeters mounting hardware shown below is included.
Integral Flowmeter
Model
Part name
Qty.
AXG###
Centering Device (*1)
1 set
Blanking Plug
1 pcs.
Gasket (sensor side) (*2)
2 sheets
Remote Transmitter
Model
Part name
Qty.
AXG4A
Mounting Bracket
1 set
Blanking Plug
1 pcs.
*1:
When the following process connection codes (wafer type)
have been selected, the centering device is attached. AA1, AA2
*2:
When the following code is specified for “Lining”, gaskets
(sensor side) are attached. The gaskets (customer pipe
side) should be prepared by customers. - Lining code: C
2.1
Model and Specifications Check
As shown in Figure 2.1 to Figure 2.3, the model, suffix
code, serial number, meter factor, fluid specification,
and device information are found on the name plate
located on the outside of the housing. And, this product
can check their information from parameters. Read the
user’s manual of applicable communication type as
listed in Table 1.1 for checking device information from
parameters.
When checking the matching of model and specification
you ordered, see the applicable general specifications as
listed in Table 1.1.
Be sure you have the model code and serial number
available when contacting YOKOGAWA.
The model and specification described on the nameplate
are those of the state at the time of shipment.
Note: Description on the nameplate
- Made in _______: Country of origin
- COMB No.: Serial number of the combined remote
sensor or remote transmitter
F0201.ai
Figure 2.1 Name Plate (AXG Integral Flowmeter)
F0202.ai
Figure 2.2 Name Plate (AXG Remote Sensor)
F0203.ai
Figure 2.3 Name Plate (AXG4A Remote Transmitter)
2.2 Storage Precautions
(Please read the descriptions on IM 01E22A01-01EN.)