Load Impedance 

1 Ω or less

Max. Output Voltage  30 V peak or less (restricted by the output protection circuit).  

Working Voltage 

Max. 600 Vrms

Influence of Adjacent Conductor  When the frequency of the current in an adjacent conductor is 50 Hz, the 

influence on the primary current is 0.5 mA/A or less.  

Influence of Conductor Position in the Jaws  0.1% or less in the output signal for a frequency of 400 Hz or less.  

Influence of Load Impedance r  When 1 Ω < r ≤ 5 Ω, under 0.1% of output signal, and phase shift under 0.2 degrees

Influence of Frequency f

§

 

30 Hz ≤ f < 48 Hz: under 0.5% of output signal

    

 

65 Hz < f ≤ 1 kHz: under 1% of output signal

    

 

1 kHz < f ≤ 5 kHz: under 2% of output signal

Influence of Crest Factor 

Under 1% of output signal, given a crest factor of 6 or less for a 2000 A peak   

 

 

(333 Arms) current or less 

Influence of DC Current Superimposed on Nominal Current

    

 

Under 1% of the output signal, assuming a current of DC 15 A or less.  

Operating Temperature –10°C to +50°C

Storage Temperature  –40°C to +70°C

Temperature Influence  0.02%/°C or less of the output signal

Operating Humidity 

0 to 90% RH (no condensation)  However, if 35°C is exceeded, humidity will impair the 

primary functionality (by a factor of 0.5% RH/°C)

Influence of Humidity  Under 0.1% of the output signal given 10% RH ≤ Humidity < 20% RH or 

    

75% RH < Humidity ≤ 90% RH

Operating Altitude 

2000 m or less above sea level

Max. Jaws Openin g 

53 mm (open jaws height: 139 mm (W))

External Dimensions  Approx. 111(W) x 216(H) x 45(D) mm

Weight 

Approx. 620g.

Output 

Safety jacks (Φ4 mm)

Measurement category

 

describes a number which defines a transient overvoltage condition.  It implies the 

regulation for impulse withstand voltage.  

  Measurement category III applies to measurement of the distribution level, that is , building wiring, fixed 

installations.  Measurement  category  IV  applies  to  measurement  of  the  primary  supply  level,  that  is, 

overhead lines, cable systems, and so on. 

† 

Pollution degree

 describes the degree to which a solid, liquid, or gas which deteriorates dielectric strength 

or surface resistivity is adhering.

  Pollution  Degree  2  applies  to  the  normal  indoor  atmosphere.    Normally,  only  non-conductive  pollution 

occures.  Occasionally, however, temporary conductivity caused by condensation must be expected.

‡  Reference Conditions

  Temperature: 23 °C±3°C 

Humidity: 20 to 75% RH 

External magnetic field < 40 A/m 

No AC magnetic field   

Conductor centered in jaws 

Load impedance ≤ 1 Ω (≤ 1 VA)

  No influence of current flowing in adjacent conductors

  When the primary current is sinusoidal, the sinusoidal conditions are: frequency; 48 to 65 Hz, distortion 

factor < 1%, no DC component

§  There is no frequency influence in the range 48 Hz ≤ f ≤ 65 Hz.

 

99

111

101

52

216

43.5

31

35

45

External Dimensions (Units: mm)

6.  Maintenance

•  Note the following when cleaning the probe.  

 

•  Do not clean the probe while clamped to a conductor.  Likewise, do not clean while 

connected to a measuring instrument.  

 

•  Do not allow water to contact the jaws.  

•  When opening the jaws, keep the exposed metal areas clean.  If dust accumulates, wipe with a 

clean dry cloth.  To prevent rust, wipe metal surfaces with oil from time to time.  Avoid getting oil on 

non-metallic surfaces.  Use only high quality, low-viscosity machine oil such as sewing machine oil. 

•  This product undergoes a 100% inspection at the time of shipment. If any layers of the core 

come apart slightly during shipment, this will not affect the functioning of the product. 

  

Four metal surfaces are 

exposed with the clamp 

is opened. 

Metal surfaces

7.  Servicing

 

If you encounter any problems during use, or if the device does not appear to be operating normal

-

ly, contact your dealer or nearest YOKOGAWA representative.

8.  Appendix

 

Waste Electrical and Electronic Equipment

Waste Electrical and Electronic Equipment (WEEE), Directive

(This directive is valid only in the EU.)

This product complies with the WEEE directive marking requirement. This marking 

indicates that you must not discard this electrical/electronic product in domestic 

household waste.

Product Category

With reference to the equipment types in the WEEE directive, this product is classified 

as a “Monitoring and control instruments” product.
When disposing products in the EU, contact your local Yokogawa Europe B.V. office. 

Do not dispose in domestic household waste.

 

Authorized Representative in the EEA

 

Yokogawa Europe B. V. is Authorized Representative of Yokogawa Test & Measurement Corporation

 

in the EEA for this Product. To contact Yokogawa Europe B. V., see the separate list of worldwide 

contacts, PIM 113-01Z2.

IM 751552-01E  2/2

Отзывы: