background image

Waste Electrical and Electronic Equipment

 

Waste Electrical and Electronic Equipment

 

(This directive is valid only in the EU.)

 

This product complies with the WEEE directive marking requirement. This marking 

indicates that you must not discard this electrical/electronic product in domestic 

household waste.

 

Product Category

 

With reference to the equipment types in the WEEE directive, this product is classified 

as a “Monitoring and control instruments” product.

 

Do not dispose in domestic household waste. When disposing products in the EU, 

contact your local Yokogawa Europe B. V. office.

Authorized Representative in the EEA

Yokogawa Europe B.V. is the authorized representative of Yokogawa Meters & Instruments Corporation 

for this product in the EEA. To contact Yokogawa Europe B. V., see the separate list of worldwide 

contacts, PIM 113-01Z2.

Measurement Category

To ensure safe operation of measuring instruments, IEC 61010 establishes safety standards for various 

electrical environments, categorized as O to IV, and called measurement categories.

Measurement category O (Other)

  Applies to measurement of circuits that are not directly connected to a main power source. This 

category applies to measurement of secondary electric circuits in equipment across a transformer.

Measurement category II

  Applies to measurement of circuits, such as household electric appliances and portable electric 

tools, that are connected to low-voltage installations.

Measurement category III

  Applies to measurement of facility circuits, such as distribution boards and circuit breakers.

Measurement category IV

  Applies to measurement of power source circuits, such as entrance cables to buildings and cable 

systems, for low-voltage installations.

Component Names

 

Transformer jaw

Barrier

Trigger

Cable

Output connector

Specifications

Measurable conductor size

720930: Max. φ18 mm, 720931: Max. φ30 mm

Measuring range

720930: AC 0 to 50 Arms,

720931: AC 0 to 200 Arms (300 Apeak)

Output voltage

720930: AC 0 to 500 mVrms (10 mV/A)

720931: AC 0 to 500 mVrms (2.5 mV/A)

Accuracy 

(sine wave input)

Bandwidth

720930

 

±0.5%rdg±0.1 mV (50/60Hz)

 

±0.8%rdg±0.2 mV (40 Hz to 1 kHz)

 

±1.0%rdg±0.4 mV (1 kHz to 3.5 kHz)

720931

 

±0.5%rdg±0.1 mV (50/60 Hz)

 

±0.8%rdg±0.2 mV (40 Hz to 1 kHz)

 

±1.0%rdg±0.4 mV (1 kHz to 3.5 kHz)

Phase

720930: Within ±2.0 deg (0.5 to 50 A, 40 Hz to 3.5 kHz)

720931: Within ±1.0° deg (2 to 200 A, 40 Hz to 3.5 kHz)

Accuracy-guaranteed temperature 

and humidity

23±5°C, Humidity: 85%RH or less (no condensation)

Rated voltage between circuit and 

ground

720930: AC 300 Vrms max.

720931: AC 600 Vrms max.

Operating temperature & humidity 

range

0 to 50°C, 85%RH or less (no condensation)

Storage temperature & humidity 

range

-20 to 60°C, 90%RH or less (no condensation)

Temperature coefficient

0.05% f.s./°C (0 to 50°C)

Maximum allowable input

720930: AC 130 Arms continuous (50/60 Hz)

720931: AC 250 Arms continuous (50/60 Hz)

Influence of the conductor location 720930: Within ±0.5% rdg (1 to 50 A, 45 Hz to 1 kHz)

720931: Within ±0.5% rdg (20 to 200 A, 45 Hz to 1 kHz)

Influence of the external magnetic 

field

720930: Equivalent to 0.1 A or less (400 A/m, 50/60 Hz)

720931: Equivalent to 0.1 A or less (400 A/m, 50/60 Hz)

Output impedance

720930: Approx. 18 Ω, 720931: Approx. 6 Ω

Withstand voltage

720930

 

AC 3.7 kVrms / 1 minute

 

Between jaw and case, case and output terminal, output terminal and jaw.

720931

 

AC 5.4 kVrms / 1 minute

 

Between jaw and case, case and output terminal, output terminal and jaw.

Environmental conditions

Altitude up to 2000 m, in-door use

Recommended calibration period 1 year
External dimensions

720930: 52 (W) × 106 (H) × 25 (D) mm (excluding protrusions)

720931: 73 (W) × 130 (H) × 30 (D) mm  (excluding protrusions)

Cable length

Approx. 2.8 m

Output terminal

BNC connector (isolated)

Weight

720930: Approx. 210 g, 720931: Approx. 280 g

Standard accessories

Instruction manual, cable marker

Safety standards

Compliant standards:  EN 61010-1, EN 61010-2-032

Measurement category

 

720930: 

 Measurement category III (rated voltage between 

circuit and ground: 300 Vrms) 

  

 

Measurement category IV (rated voltage between 

circuit and ground: 150 Vrms) 

 

720931: 

 Measurement category III (rated voltage between 

circuit and ground: 600 Vrms) 

  

 

Measurement category IV (rated voltage between 

circuit and ground: 300 Vrms) 

Pollution degree 2

*

EMC standards

Compliant standard:  EN 61326-1

 

Influence in the immunity testing environment (criteria A)

 

720930: 

Equivalent to 10 A or less

 

720931: 

Equivalent to 40 A or less

Environmental standards

Compliant standard:   EN 50581 Monitoring and control instruments 

including industrial monitoring and control instruments

*  Pollution Degree applies to the degree of adhesion of a solid, liquid, or gas that deteriorates 

withstand voltage or surface resistivity. Pollution degree 2 applies to normal indoor atmospheres 

(with only non-conductive pollution).

External Dimensions

 

52

Ø30

720930

720931

106

25

Ø18

130

73

Unless otherwise specified, tolerances are ±3% (however, tolerances are ±0.3 mm when below 10 mm).

Unit: mm

30

2880

±60

2880

±60

Measurement

 WARNING

The transformer jaws are made of metal and their tips are not completely 
insulated. Be especially careful about the possible shorting where the measured 
object has exposed metal parts.

 CAUTION

•  Take sufficient care to avoid shock, vibration, or excessive force when handling 

the instrument. Otherwise, the precisely adjusted transformer jaws will be 

damaged.

•  When transformer jaws do not fully close, never try to close them by force, but 

make them free to move and try again. If a foreign substance is stuck in the jaw 

tips, remove it.

•  When making current measurements, keep the transformer jaws fully closed. 

Otherwise, accurate measurements cannot be taken. 

Maximum conductor size is as follows.

   

720930: 18 mm in diameter

   

720931: 30 mm in diameter

•  Hold the inserting part (not the cable), and disconnect the output connector 

from the measuring instrument so as not to break the cord.

French

 AVERTISSEMENT

Les mâchoires du transformateur sont composées de métal et leurs embouts ne 
sont pas totalement isolés. Il faut être particulièrement attentif à un éventuel court-
circuit là où l'objet mesuré possède des parties métalliques exposées.

 ATTENTION

•  Procéder avec suffisamment de soin pour éviter les chocs, les vibrations ou 

une force excessive lors de la manipulation de l'instrument. Si cette condition 

n'est pas respectée, les mâchoires du transformateur ajustées avec précision 

seront endommagées.

•  Si les mâchoires du transformateur ne ferment pas totalement, ne jamais 

essayer de les fermer en forçant, mais les laisser libres et réessayer. Si une 

substance étrangère est bloquée dans les extrémités de la mâchoire, la retirer.

•  Lors de la prise de mesures d'intensité, maintenir les mâchoires du 

transformateur entièrement fermées. Si cette condition n'est pas respectée, il 

est impossible d'effectuer des mesures précises.

  La taille maximale du conducteur est la suivante. 

 

Modèle 720930: 18 mm de diamètre 

 

Modèle 720931: 30 mm de diamètre.

•  Maintenir la partie d'insertion (excepté pour le câble) et débrancher le 

connecteur de sortie de l'instrument de mesure afin de ne pas entraîner une 

rupture au niveau du cordon.

Measurement procedures

1. 

Connect the output connector to the Input terminal of the measuring instrument.

2. 

Press the trigger to open the transformer jaws and clamp onto one conductor. The measured 

conductor shall be at the center of the jaws.

 

When connecting a sensor with a power meter, match the arrow mark (power source to 

load), which is indicated on the transformer jaws, with the current flowing direction in order to 

synchronize the phases of measured current and output voltage.

3. 

Ensure that the tips of transformer jaws are firmly closed.

  

Current direction arrow

Conductor

Power source

Load

Disposing of the Instrument

When disposing of this instrument, follow the laws and ordinances of the country or region where the 

product will be disposed of.

IM 720930-01EN  2/2

nbn Elektronik Handelsgesellschaft m. b. H.

Riesstraße 146, 8010 Graz 

www.nbn.at  

Tel. +43 316 40 28 05  |  Fax +43 316 40 25 06

Vertrieb für Österreich :

Отзывы: