Safe Usage

Environmental Warnings     –– Warning    –– Caution

_

Environmental warninngs/Cautions

KEEP  THE  THERMOMETER
AWAY FROM DROPPING WATER
AND DO NOT USE IN WATER.
This thermometer is not water-proof-
ing. Usage in such environments
may cause irreparable damages.

AVOID MEASURING SHINY OB-
JECTS.
Shiny objects reflect surrounding
temperatures. As this thermometerís
sensitivity to emissivity is fixed, the
displayed temperature could differ
form the actual temperature of ob-
jects that have different emissivity
values.

DO  NOT  LET THE THERMOM-
ETER TOUCH THE OBJECT THAT
IS BEING MEASURED.
This  product  is  a  non-cotact
themometer. Touching high-tem-
perature object may cause deforma-
tion of the meter, irreparable dam-
age or incorrect measurement.

KEEP  THE  THERMOMETER
AWAY FROM DIRECT SUNLIGHT,
DUST,HIGH  TEMPERATURES
AND  HIGH  HUMIDITY  DURING
USE AND STORAGE.
This may cause irreparable damage
or incorrect measurement.

DO NOT TOUCH THE FILTER.
Do not let a solid or sharp object
touch the filter and do not insert for-
eign objects into the filter. These may
cause incorrect measurement.

USE THE SPECIFIED BATTERIES.
Use of the other batteries may cause
irreparable  damage  or  incorrect
measurement.

Usage Warnings     –– Warning    –– Caution

GGGGGGGGG

KEEP  THE  THERMOMETER
AWAY FROM SUDDEN CHANGE
IN AMBIENT TEMPERATURE.
Sudden temperature change may
cause incorrect measurement. Start
measurement when temperature
has become stable after leaving the
meter for a while.

KEEP THE THERMOMETER AWAY
FROM STRONG ELECTROMAG-
NETIC SOURCES.
Usage in such environments may
cause irreparable damage or incor-
rect measurement.

DO NOT DROP THIS THERMOM-
ETER NOR GIVE A STRONG IM-
PACT TO IT, WHICH MAY CAUSE
IRREPARABLE DAMAGE OR IN-
CORRECT MEASUREMENT.

DO NOT BRING THE THERMOM-
ETER CLOSE TO ELECTRICALLY
CHARGED OBJECTS.
This may cause irreparable damage
or incorrect measurement.

53005-6E  12.5.12 10:04 AM  ページ 4

Содержание 53005-E

Страница 1: ...es Act Republic of Korea This product complies with the Radio Waves Act Republic of Korea Note the following when using the product in Republic of Korea The product is for business use Class A and mee...

Страница 2: ...Electronic Information Products of the People s Republic of China 2 3 4 5 6 8 9 9 9 10 11 12 13 13 13 13 14 15 17 18 18 18 19 19 20 21 22 24 Thank you very much for purchasing Thermometers products T...

Страница 3: ...result in hazardous radiation exposure Safe Usage When operating the instrument be sure to observe the cautionary notes given below to ensure correct and safe use of the instrument If you use the ins...

Страница 4: ...DITY DURING USE AND STORAGE This may cause irreparable damage or incorrect measurement DO NOT TOUCH THE FILTER Do not let a solid or sharp object touch the filter and do not insert for eign objects in...

Страница 5: ...00 1 Repeatability 1 of reading value Display resolution 30 0 to 199 9 0 1 200 to 600 1 Sighting method Coaxal laser marker Class 2 HOLD time 15 seconds Continuous measurement mode ON OFF Selectable U...

Страница 6: ...6 There is no button to turn ON OFF the supper supply Name of Components...

Страница 7: ...a Class 2 laser product as de fined by IEC60825 1 Safety of Laser Products Part1 Equip ment classification and require ments In addition this instru ment complies with 21 CFR 1040 10 except for devia...

Страница 8: ...supplied as an accessory and operate the unit according to the folloowing procedure 1 Point the laser beam at a measurement objectandaimitatthecenteroftheareato be measured For the distance from this...

Страница 9: ...ing measurement is displayed on the sub display MIN MIN is displayed at the bottom of LCD and the minimum value during measurement is displayed on the sub display Selection of display function Default...

Страница 10: ...acle However please note that the measuring field of view enlarges in proportion to the measuring distance This thermometer has an optical resolution of 33 1 D Distance to the measuring object S Spot...

Страница 11: ...ppliedexcluding that AL H on the sub display is changed to AL L in step 2 and later When the lower limit setting has been completed the mode is changed to HOLD When the upper and lower limit alarms ar...

Страница 12: ...12 53005 P 13 Recording Measured Temperature Record Measured Temperature MEM Mode Call Temperature Record CALL Mode P 13 Emissivity Setting...

Страница 13: ...ll objects has their own emissivity which changes depending on the surface conditions and object temperature This thermometer has 3 fixed emissivities Refer to the following examples 0 95 Food rubber...

Страница 14: ...me Setting P 17 Emissivity Setting P 18 Recording Measured Temperature Record Measured Temperature MEM Mode Call Temperature Record CALL Mode Delete All the Temperature Records P 19 Continuous Measure...

Страница 15: ...s ON After the set year blinks date blinks then the display is automatically shifted to the state that date lights up the left 2 digits of the clock month blinks and the right 2 digits day lights up T...

Страница 16: ...ts minute light up 7 8 Press the MAX MIN or MEM CAL button to adjust the hour Then press the MEASURE button to fix the setting After the setting the right 2 digits of the clock start to blink for the...

Страница 17: ...ect other than the measured object such as a high temperature object exists on the periphery temperature for the other object is reflected which will cause incorrect measurement Thus it is necessary t...

Страница 18: ...capacity FULL lights up on LCD 1 Press this button for 2 seconds or more while the power is ON Call temperature record CALL mode CALL is displayed on the sub display and then the latest stored temper...

Страница 19: ...ing in page 7 CONT is lit on LCD and continuous measurement is started Measurement continues even if releasing the MEASURE button 1 When the MEASURE button is pressed again or the DIP switch is change...

Страница 20: ...ng revising and writing of data inside thermometer 2 PC can read all date instantly on thermometers continuous mode 3 Output all data by CSV format 4 Set up each parameters Clock Emissivity Change mem...

Страница 21: ...lace the batteries The b sign blinks or re install the batteries correctly The lens unit is stained Clean the lens referring Lens of Maintenance described in page 22 Field of view is deviated from the...

Страница 22: ...es are to be used for checking operations The battery life mentioned in Specifications is not assured for these batteries Precaution when handling batteries Do not dispose exhausted batteries in a fir...

Страница 23: ...23...

Страница 24: ...24...

Отзывы: