YOKOGAWA 53005-E Скачать руководство пользователя страница 1

Printed in JAPAN 2012/05

Model:

53005/53006

Emission Thermometer

User’s Manual

Tachihi bldg, No.2, 6-1-3 Sakaecho, Tachikawa-shi, Tokyo, 190-8586 Japan

Phone:+81-42-534-1413        Fac81-42-534-1438

YOKOGAWA EUROPE B. V. (THE NETHERLANDS)

Euroweg 2, 3825HD, Amersfoot, THE NETHERLANDS

Phone: 31-88-4641000, Facsimile: 31-88-4641111

Compliance with the Radio Waves Act (Republic of Korea)

This product complies with the Radio Waves Act (Republic of Korea).

Note the following when using the product in Republic of Korea.

The product is for business use (Class A) and meets the electromagnetic

compatibility requirements.The seller and the user must note the above

point and use the product in a place except for home.

 

 Registration No:

  Equipment Name:

  Trade Name:

  Manufacturer:

  Country of Origin:

KCC-REM-IMY-EEN326

Emission Thermometer

Yokogawa Meter & Instruments Corporation

Yokogawa Meter & Instruments Corporation

Japan

 

Содержание 53005-E

Страница 1: ...es Act Republic of Korea This product complies with the Radio Waves Act Republic of Korea Note the following when using the product in Republic of Korea The product is for business use Class A and mee...

Страница 2: ...Electronic Information Products of the People s Republic of China 2 3 4 5 6 8 9 9 9 10 11 12 13 13 13 13 14 15 17 18 18 18 19 19 20 21 22 24 Thank you very much for purchasing Thermometers products T...

Страница 3: ...result in hazardous radiation exposure Safe Usage When operating the instrument be sure to observe the cautionary notes given below to ensure correct and safe use of the instrument If you use the ins...

Страница 4: ...DITY DURING USE AND STORAGE This may cause irreparable damage or incorrect measurement DO NOT TOUCH THE FILTER Do not let a solid or sharp object touch the filter and do not insert for eign objects in...

Страница 5: ...00 1 Repeatability 1 of reading value Display resolution 30 0 to 199 9 0 1 200 to 600 1 Sighting method Coaxal laser marker Class 2 HOLD time 15 seconds Continuous measurement mode ON OFF Selectable U...

Страница 6: ...6 There is no button to turn ON OFF the supper supply Name of Components...

Страница 7: ...a Class 2 laser product as de fined by IEC60825 1 Safety of Laser Products Part1 Equip ment classification and require ments In addition this instru ment complies with 21 CFR 1040 10 except for devia...

Страница 8: ...supplied as an accessory and operate the unit according to the folloowing procedure 1 Point the laser beam at a measurement objectandaimitatthecenteroftheareato be measured For the distance from this...

Страница 9: ...ing measurement is displayed on the sub display MIN MIN is displayed at the bottom of LCD and the minimum value during measurement is displayed on the sub display Selection of display function Default...

Страница 10: ...acle However please note that the measuring field of view enlarges in proportion to the measuring distance This thermometer has an optical resolution of 33 1 D Distance to the measuring object S Spot...

Страница 11: ...ppliedexcluding that AL H on the sub display is changed to AL L in step 2 and later When the lower limit setting has been completed the mode is changed to HOLD When the upper and lower limit alarms ar...

Страница 12: ...12 53005 P 13 Recording Measured Temperature Record Measured Temperature MEM Mode Call Temperature Record CALL Mode P 13 Emissivity Setting...

Страница 13: ...ll objects has their own emissivity which changes depending on the surface conditions and object temperature This thermometer has 3 fixed emissivities Refer to the following examples 0 95 Food rubber...

Страница 14: ...me Setting P 17 Emissivity Setting P 18 Recording Measured Temperature Record Measured Temperature MEM Mode Call Temperature Record CALL Mode Delete All the Temperature Records P 19 Continuous Measure...

Страница 15: ...s ON After the set year blinks date blinks then the display is automatically shifted to the state that date lights up the left 2 digits of the clock month blinks and the right 2 digits day lights up T...

Страница 16: ...ts minute light up 7 8 Press the MAX MIN or MEM CAL button to adjust the hour Then press the MEASURE button to fix the setting After the setting the right 2 digits of the clock start to blink for the...

Страница 17: ...ect other than the measured object such as a high temperature object exists on the periphery temperature for the other object is reflected which will cause incorrect measurement Thus it is necessary t...

Страница 18: ...capacity FULL lights up on LCD 1 Press this button for 2 seconds or more while the power is ON Call temperature record CALL mode CALL is displayed on the sub display and then the latest stored temper...

Страница 19: ...ing in page 7 CONT is lit on LCD and continuous measurement is started Measurement continues even if releasing the MEASURE button 1 When the MEASURE button is pressed again or the DIP switch is change...

Страница 20: ...ng revising and writing of data inside thermometer 2 PC can read all date instantly on thermometers continuous mode 3 Output all data by CSV format 4 Set up each parameters Clock Emissivity Change mem...

Страница 21: ...lace the batteries The b sign blinks or re install the batteries correctly The lens unit is stained Clean the lens referring Lens of Maintenance described in page 22 Field of view is deviated from the...

Страница 22: ...es are to be used for checking operations The battery life mentioned in Specifications is not assured for these batteries Precaution when handling batteries Do not dispose exhausted batteries in a fir...

Страница 23: ...23...

Страница 24: ...24...

Отзывы: