background image

DS1054-055A

P15

6. Use buttons 

 and 

 to increase and decrease the values. Press button 

 to confirm 

and move on to the next parameter. In order: seconds / minutes / hour / year / month / day.

7. Once all parameters have been set, hold button 

 pressed for 3 seconds to exit the 

clock synchronisation menu. 

PREREQUISITES

The THERMARP thermostat can be used to control a boiler or a 230V solenoid valve 

directly via its internal relay or via the relay of a wireless receiver: MTR2000ERP(X) or 

MTR2000MRP(X).

NO

C

max 5A 250 V~

NC

NA

C

  Wires with cross-section area of 0.5 mm

2

 or larger must comply with IEC 60332-1-2; 

wires with cross section area smaller than 0.5 mm

2

 must comply with IEC 60332-2-2.

In the case of a wireless receiver, before pairing the thermostat and the wireless receiver, 

the MTR2000ERP(X) or MTR2000MRP(X) receiver must be wired and powered.

Direct wiring

Содержание Thermarp

Страница 1: ...CTA O RADIO DIGITALER THERMOSTAT MIT DIREKT ODER FUNKVERBINDUNG DIGITALETHERMOSTAATMETDIRECTEOFRADIOSIGNAALBEDIENING DIGITAL TERMOSTAT MED DIREKTE FORBINDELSE ELLER RADIO GUIDE DE D MARRAGE RAPIDE GUI...

Страница 2: ...base until the previous screen is displayed Couple first the teeth on the top side No programming or changes can be made to the set parameters until the device is properly attached to the wall base 4...

Страница 3: ...can be used to control a boiler or a 230V solenoid valve directly via its internal relay or via the relay of a wireless receiver MTR2000ERP X or MTR2000MRP X NO C max 5A 250 V NC NA C Wires with cross...

Страница 4: ...ds until the CLOCK icon starts flashing Use the arrows and to move through the various items of the configuration menu until the RF WIRELESS menu is displayed Tap on the Validate icon A B Always make...

Страница 5: ...erature values Important The THERMARP thermostat may not be able to communicate with the receiver if it is out of range The message Err 17 will appear on the display in this case See the How to extend...

Страница 6: ...e boiler Pair the THERMARP thermostat with the module that controls the boiler following the steps described above 3 Set the access point on the wireless bus Place the thermostat in its final position...

Страница 7: ...for purposes other than those specified 5 In case of malfunction do not attempt to repair the product but contact Technical Support at the numbers Customer Service 39 011 23 39 810 Export Dept Phone 3...