230V ~
10A
230V ~
P2
P1
N L
Pulsanti opzionali
C1 N
C2
BP
L
RADIO: 2000W TIMED RELAY MODULE
Functions
This module may be used in wireless mode and by one or more
additional local pushbuttons.
Technical Specifications
Mains voltage: 230V
~
+10% -15% - 50Hz
Power on resistive load: Max. 10A 2000W
Module consumption: < 1VA - < 0.3W
Radio frequency: 2.4GHz
Sound level: <60dB a 20 cm
Ambient temperature: from -20°C to +40°C
Relative humidity: 0 - 90%
Dimensions: 48 x 33 x 22.5 mm
[1.96 x 1.30 x 0.88”]
MTR2000eRX
5454455
Radio: 2000W Timed Relay with Aerial
MTR2000eRP
5454462
Radio: POWeR 2000W Flush-mounted
Timed Relay
MTR2000eRPX
5454463
Radio: POWeR 2000W Flush-mounted
Timed Relay Module with external Aerial
RAdIO RANGe
Standard Range:
•
In the same room (< 100 m²)
• 50 m in open range
POWeR Range (*):
•
Inside 100 m² apartments with
perpendicular crossing of main wall or
ceiling
• 250 m in open range
(
Note: in both cases the range may be
reduced by the presence of metallic
elements, crossing of walls, or partitions
)
RAdIO TRANSMISSION
The transmitter Led will light up only if
the radio transmission was successful.
Adding an intermediate receiver will solve
the problem of an insufficient range.
Refer to the transmitter instruction booklet
for more information.
Special features of the MTR2000eR:
Switches may be used instead of pushbuttons
with the MTR2000ER receiver (an E2BP transmitter must
be used).
To establish a connection, switch
5
times rapidly (not 10!), instead of 5 pulses. Simply repeat the connection
procedure with 5 pulses to use a pushbutton instead of the switch again.
WIRING
Optional pushbuttons
IMPORTANT
:
Before starting any configuration, press
briefly
23
times to unlock the relay.
The module will lock again
automatically after 6 hours.
It can also be locked immediately with
21
short presses.
DS1054-012F
P8
(*) Contact an Urmet retailer or go to www.yokis.com for information on availability
GB
Installing Cautions
The module must be installed only by qua-
lified personnel and into a place the end-
user cannot access, according to the
installing national rules.
In order to follow the safety rules, the
module must be connected to a power line
that is upstream protected by a magneto-
thermic switch 10A C curve.
Except MTV500ER, for all other YOKIS
radio receiver modules you must use a
pointed and properly insulated tool to
press the “connect” hole shortly.