How to Clean the Air intake

1) Open the air intake grille.

2) Remove the air filters.

3) Open the grille at a 45 Degree angle and then lift, 
    it up to take away.

See step 1 of "How to Clean the Air Filter"

See step 2 of "How to Clean the Air Filter"

4) Wash with water.
    When the air intake grille is very dirty, use soft 
    brush and neutral detergent. Shake off water 
    and air dry in a shady place.
    Attention: Do not wash with hot water.

5) Replace the grille

6) Replace the air filter.

7) Close the suction grille

Refer to step 3.

See step 4 of "How to Clean the Air Filter"

Refer to step 1.

Before Starting the Unit for the First Time in the Season

1) Check to make sure no objects obstructing the in
    take and outlets on both the indoor and outdoor 
    units.
2) Check to make sure ground wire is connected 
    and that it is not damaged.
3) Check to make sure air filter has been cleaned.
4) Turn on the power 6 hours before starting the air
    conditioner.

1) Clean the filter and the body of the unit.
2) Turn off power.
3) Clear dust.
4) If there is any rust deep inside the outdoor unit, 
    may need to use an extended head cleaning tool.

End of Seaseon Cleaning

CARE AND MAINTENANCE

CARE AND MAINTENANCE

Pull out the power plug before cleaning

Do not splash water directly to the unit

WARNING

Note:

5) Shut the air intake grille.

Refer to step 1.

1) Open the air intake grille and use a phillips head 
    screwdriver to remove the two screws.

    Slide both knobs simultaneously towards center
    as shown and then pull them downward slowly.

2) Remove the air filters.

Slide knobs on the back of the airintake grille
outward and remove the air filter.
Then remove three air filters on it.

How to Clean the Air Filter

3) Clean the air filter.

If filters are not dirty, you can just vacuum or 
wash the air filter with clean water. If the air 
filters are very dirty. Use mild detergent and 
water. Leave the air filter to dry naturally in a 
shady place.

* Do not clean with hot water.
* Do not dry over fire.
* Do not run the air conditioner without the air filter.
* The suction grille must be opened carefully, air 
  intake.

4) Put back the air filters
    * Replace the air filter into its holder.

    * Make sure the air filter makes contact with the 
      filter stopper when it is replaced into its holder.

Содержание WMMS-12EC-V2B

Страница 1: ...LIT WMMS 59 2 EC DC IVTR II 20131130 For Ceiling Cassette Styles 59 12 to 24K Btu h Cooling and Heat Pump This Manual is Subject to Change to Reflect Our Continuous Effort for Engineering Improvement without Prior Notice YMGI is the Trademark and Property of YMGI Group Copyright of YMGI Group 2013 YMGI Engineered HVAC R Products for Maximum Green World and Better Tomorrow YMGI Group POB 1559 O Fal...

Страница 2: ...al support division directly at Dear Customer s end User s unit Purchaser s installer s Contractor s Thanks for choosing YMGI products The YMGI equipment you purchased is either a split type or a self contained cooling heating system which requires an installer s license certification knowledge experience carefulness and details for a successful and good installation This equipment is different fr...

Страница 3: ...re humidity ranges installation operation maintenance service warranty parts and so on 4 Properly select correct most suitable YMGI product models of units and accessories for your HVAC applications jobs and list them in your proposal quote in writing on your company s quote form or letter head basing upon the information you get from 1 2 and 3 above 5 List your currently valid HVAC license and EP...

Страница 4: ...the installation 5 Supply electrical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to outdoor unit 9 The size of HVAC circuit breaker fuse or disconnect switch to the outdoor unit 11 What is the refrigerant pipe length between each indoor unit and the outdoor unit Unit A Unit B Unit C Un...

Страница 5: ...thorized contractor in YMGI list that is close to you otherwise 4 Authorized Distributor in YMGI Distributor list otherwise 5 Contractor Distributor you prefer who is close to you CONTACT FOR GENERAL TECHNICAL QUESTIONS OR SUPPORT IN A SEQUENCE 1 The original installer otherwise 2 The current service contractor otherwise 3 The distributor where the unit is purchased from otherwise 4 YMGI Technical...

Страница 6: ...s Net L x W x H In Package L x W x H In Net LBs Packaged LBs 20 40 40 HQ WMMS 12EC V2B 59 2 208 230 1 60 187 253V 13900 12000 5200 13000 11600 9000 16 8 2 2 96 353 312 245 25 18 Upon Mounting Height Speed Temp 0 39 37 35 49 47 45 FN11T 2 Single 700 600 515 11 50 1 Centrifugal 1 11 1 x 5 8 MP35CB 2 2 NA T3 15A 250V 0 2A Alu Fin Inner Grooved Copper Tube Blue Yes 1 4 3 8 1 22 Yes 25 Yes Standard Was...

Страница 7: ...te circuit and suitable fuse Be sure to install an earth leakage breaker Diameter of power supply cord must be big enough Refer to P24 about the sizes of diameter If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard The appliance shall be installed in accordance with relative wiring regulations 2 Pleas...

Страница 8: ...ot installed in the laundary CEILING OPENING AND SUSPENSION BOLT M10 PITCH DEMENSION HANGING PREPARATIONS Firmly fasten the hanging bolts as shown in Fig 4 or by another method Fig 4 Fig 5 Keep clearance 12Ft or more Exhaust of large capacity Heat 22 5 22 5 9 1 25 6 25 6 1 97 12EC 18EC 24EC W L H a b c 33 1 33 1 9 1 37 4 37 4 2 4 22 5 22 5 9 1 25 6 25 6 1 97 Fig 3 W a L c b H a b INSTALLATION ACCE...

Страница 9: ...nut B onto the hanging bolt Fig 6 2 Raise the body and mount its hooks onto the hanging bolt between the special nuts Fig 6 3 Turn special nut B to adjust the height of the body Fig 6 4 Use a level or vinyl hose filled with water to adjust the unit to level Warning Fig 6 INDOOR UNIT INSTALLATION INSTALLING DRAIN PIPE NOTE Install the drain pipe Install the drain pipe with a downward gradient 1 50 ...

Страница 10: ...nd outdoor unit wiring terminal Note The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube An all pole disconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule CONNECTION OF REFRIGER...

Страница 11: ...and tighten the terminal screw to hold the exposed solid wire loop securely B For strand wiring 1 Cut the wire end with a wire cutter then strip the insulation to about 3 8 10mm to expose the solid wire 2 Using a screwdriver remove the terminal screw s on the terminal board 3 Using a round terminal fastener or plier securely clamp a round terminal to each stripped wire end 4 Position the round ter...

Страница 12: ...AFTER INSTALLATION 1 Prepare for test 1 Do not turn on the power switch before all installation is finsihed 2 Connect wires correctly and firmly 3 Open the check valve 4 Remove all dust 2 Testing 1 Turn on the power switch and press ON OFF button 2 Press MODE button to select COOL HEAT FAN etc to test whether it operates normally 3 Emergency operation When the unit is stopped you can press the AUT...

Страница 13: ... turned off TIMER ON BUTTON This button allows you to set a time you would like the unit to turn on The clock is a 2 hour clock Press the TIMER ON button once and you will see the word ON flashing next to a time displayed By pressing either the or the button choose the time you would like the unit to turn on Once you have the desired time displayed on the remote press the TIMER ON button once more...

Страница 14: ...sappear from the remote screen By doing so the return air temperature will take the place of remote local temperature as the unit s target temperature U TOUCH is what YOU WANT U TOUCH feature brings to you a true comfort level wherever and whenever you want SWING BUTTON Hold the swing button symbol shown above for more than 2 seconds and the indoor air louver will start to swing between the highes...

Страница 15: ...ower socket terminal block on indoor outdoor unit and all connectors on main board especially the main board of outdoor unit power module and PFC module are loosened or not GENERAL PROCEDURES TROUBLE SHOOTING OPTIMUM OPERATION Adjust the room temperature properly Adjust the room temperature properly for a comfortable environment Never place anything under the indoor unit that is to be kept dry Tur...

Страница 16: ...d will turn low after 1 minute This is caused by the refrigerant flowing inside the unit This is the noise of refrigerant caused by flow stop and flow change The noise is heard when the drainage pump is in operation No need to do anything NORMAL OCCURRENCE When normal occurrence happens Normal Occurrence Cause and remedy of normal occurrence TROUBLE SHOOTING Warning In case of something abnormal s...

Страница 17: ...ent temp sensor malfunction E1 E2 E3 E4 E5 E6 E3 E3 Defrost E5 F2 E5 E5 E9 E9 F0 F1 F3 F2 F4 E3 F5 Code indication on display Meaning NO TROUBLE SHOOTING ERROR OR PROTECTION CODE INDICATION NO Error or protection codes LED red LED yellow LED green 1 Compressor high pressure protection unit stop Blink once 2 Indoor unit anti freezing protection Twice times 3 Low pressure protection unit stop Three ...

Страница 18: ...temperature sensor when using this temperature sensor Green light blink once Blink 15 times Malfunction of jumper cap Water overflow protection Indoor ambient temperature sensor is open circuit or short circuit 2 1 3 4 5 Indoor evaporator temperature sensor is open circuit or short circuit Malfunction of ambient temperature sensor on wire controller TROUBLE SHOOTING ERROR CODE LIST Malfunction nam...

Страница 19: ...before starting the air conditioner 1 Clean the filter and the body of the unit 2 Turn off power 3 Clear dust 4 If there is any rust deep inside the outdoor unit may need to use an extended head cleaning tool End of Seaseon Cleaning CARE AND MAINTENANCE CARE AND MAINTENANCE Pull out the power plug before cleaning Do not splash water directly to the unit WARNING Note 5 Shut the air intake grille Re...

Страница 20: ...ing to include a 1 year installation service warranty at no extra charge Check with them to see if that is available If available include that in the contract 14 Verify and confirm the installation is done completely and all the unit functions have been checked and are working properly all the items in the checklist have been checked and marked well in the warranty registration card form prior to ...

Страница 21: ...e exceptions Most have resulted in equipment failure due to lack of knowledge and experience A few of the problems result from DIY s lack of knowledge in the following areas Sizing and selecting correct type size and model of cooling and or heating equipment Sizing and installing correct electric circuit breakers and wires Wiring the units correctly and properly Taping the ends connecting to indoo...

Страница 22: ...different from what are typical in traditional split type air conditioning and heat pump systems and similar systems made by other manufacturers These are not defects Take some time to learn the functions of your unit We will be happy to assist you with any questions you may have concerning the functions of your new unit 1 Part repair or replacement after trouble shooting This is the most common a...

Страница 23: ...tever questions you have or problems you have seen as a unit history No Date USER NOTES AND INSTALLATION SERVICE MAINTENANCE NOTES Notes Asked for Your Technician for Help Did You Ask YMGI Tech for Help INSTALLATION NOTES Original Installation Company Name Technician Name Phone HVAC License Job Not Performed by Technician Technician Checklist Completed Fully SERVICE MAINTENANCE NOTES No Date Conte...

Отзывы: