INSTALLATION OF OUTDOOR UNIT
It is strongly suggested to install the outdoor unit above the ground, either on a platform or brackets as shown below.
Heat pump unit must be lifted up from ground level, allowing any condensate to drain out of the drain pan in condensing
unit. Otherwise, condensate may ice up causing damage to the unit. We suggest using YMGI brackets and condensate
drainage fitting accessories.
*Actual unit/parts look/installation may vary from illustrations
INSTALLATION & PICTURES-WALL MOUNT BRACKET FOR OUTDOOR UNIT(S)
(PART VARIES UPON MODELS/AVAILABILITY)
Select a secured location where the outdoor unit can be installed properly.
Orient the unit rear side (intake grill) towards wall and front side (discharge grill) away from wall.
For ground installation, use factory-provided riser and accessories. Do not bolt unit feet directly onto ground.
Riser or brackets should be levelled at outdoor unit foot surfaces. Secure unit foot by tightening bolts, nuts and anti-
vibration pads.
For ground installation, it is recommended to use YMGI optional accessories like risers.
WIRING OUTDOOR UNIT
CONNECT WIRING BETWEEN OUTDOOR UNIT AND INDOOR UNIT
Check the nameplate for rated electrical data. Connect unit to the correct electrical power source.
Select power wire of proper type and size. YMGI suggests using UL approved 105
°
C/221
°
F multi-strand copper wire
for outdoor use. Refer to the following tables, for proper selection of wire gauge, size and circuit breaker.