YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World!
YMGI: Your Modern Green Idea
17
Capacitor
uF
8
8
3
4
5
/
Speed
Rpm/M
900/600
900/600
670 /870
780±20
800/600
790
Outdoor air flow
CFM
1147 / 765
1147 / 765
1159 / 1200
2000 / 1538
2235 / 1676
2235 / 1676
Outdoor noise level
dB(A)
53 / 35
53 / 35
53 / 41
58 / 43
59 / 44
59 / 44
Outdoor unit
Dimension
(WxDxH)
Inch
28.74” x 9.44” x
21.18”
31.96” x 10.11” x
21.25”
33.46” x 11.49” x
23.85”
35.82” x 13.38” x
27.51”
38.18” x 14.76” x
31.06”
38.18” x 14.76” x
31.06”
Packing
WxDxH)
Inch
34x13x24
36x13x23
39x16x27
41.73x18.1x37.1
44x19x35
44x19x35
Net/Gross
weight
lbs.
60/64
71/75
88/99
114/127
132/143
152/163
R410A Refrigerant
charge
Oz
31.68
39.52
45.92
68.68
70.56
116.48
Refrigerant precharge
maximum pipe length
Ft.
25
25
25
25
25
25
Additional charge for each ft.
Oz
0.23
0.23
0.23
0.23
0.23
0.23
Design pressure
PSIG
510/250
510/250
510/250
510/250
510/250
510/250
Refrigerant
piping
Liquid side/
Gas side
Inch
1/4"+3/8"
1/4"+3/8"
1/4"+1/2"
3/8”+5/8"
3/8”+5/8"
3/8”+5/8"
Max. refrigerant
pipe length
Ft.
49.2
49.2
49.2
49.2
49.2
49.2
Max. difference
in level
Ft.
16.4
16.4
16.4
16.4
16.4
16.4
Connection wires between
IDU and ODU
4×AWG18
4×AWG18
4×AWG18
4×AWG18
4×AWG18
4×AWG18
Control Type
Remote Control
Remote Control
Remote Control
Remote Control
Remote Control
Remote Control
Operation
Temperature
Ranges
Indoor
(cooling/
heating)
°F
61~90
61~90
61~90
61~90
61~90
61~90
Outdoor
(cooling /
heating)
°F
AC: 64.4 ~ 115 /
HP: -4 ~ 75
AC: 64.4 ~ 115 /
HP: -4 ~ 75
AC: 64.4 ~ 115 /
HP: -4 ~ 75
AC: 64.4 ~ 115 /
HP: -4 ~ 75
AC: 64.4 ~ 115 /
HP: -4 ~ 75
AC: 64.4 ~ 115 /
HP: -4 ~ 75
Application area
(cooling standard)
Sq. ft.
129~200
172~300
258~450
344~600
398~700
463~850
Notes:
1. Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F,
OD 47/43°F, 25 ft. copper lines and IDU 7ft. above ODU.
Unit performance varies when weather changes from the standard one.
2. Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over
size or under size equipment.
3. Watch unit operation during extreme weather conditions in summer and winter. Wind baffle helps system cooling
& heating performance in low ambient temperature ranges.
4. Heating capacities up to 85% @ 17°F ambient temperature, up to 60% @ -4°F varying upon geographic location
and actual installation.