Steps to Mount Plate
Mark all drill positions. At least 4 anchor holes are required, one at each perimeter corner of the plate. these are
needed to secure the plate, where the bold arrows are pointing, as shown in the picture above. Refer to the
specification sheet for unit weight so that enough anchors are installed at the proper locations.
Pre-drill guiding holes which are marked for anchors or screws on the wall.
Confirm the position of the holes and finish drilling to the depth required for anchors (NOT for screws).
Align the mounting plate holes with the holes drilled on the wall and put anchors or screws into the holes to
secure the mounting plate.
INSTALLATION OF INDOOR UNIT
DRILL 3 INCH HOLE FOR PIPING/WIRING/DRAIN
•
Locate the center where the hole will need to be drilled.
•
Drill the holes of 2.5
– 3 Inches in diameter. A down pitch
of about 1/4 inch per foot, as illustrated, is needed for the
hole, to drain the condensate properly.
PREPARE INDOOR UNIT- COPPER LINE SET/DRAIN HOSE
•
If pipes need to come out of the right side (facing
the front of indoor unit) of the indoor unit, snap off
portion (1) on plastic casing.
•
If pipes need to come out of the bottom side
(facing the front of indoor unit) of the indoor unit,
snap off portion (2) on plastic casing.
•
If pipes need to come out of the left side (facing
the front of indoor unit) of the indoor unit, snap off
portion (3) on plastic casing.
•
If pipes need to be rerouted to a different direction
from the one preset at factory (towards left side, if
facing the front cover of indoor unit), lay down the
indoor unit on soft cushion or foam. Don't rub the
plastic casing.
•
To keep from damaging the pipes, bend the copper tubing
set gently and slowly (A 90° bend should take a minimum of
10 seconds), by firmly holding the pipe at the root of the
original 90° bend. Don't rub the two copper lines while
bending. It is better to cut off the insulation and bend the two
pipes individually and not together.
•
If the pipes need to come out of the rear side (facing
the front of the indoor unit) of the indoor unit, there is no
need to snap off anything.
INSTALL THE INDOOR DRAIN PIPE
•
The drain hose must be placed beneath the copper
pipes and MUST NOT be kinked or bent sharply.
•
Do not pull the drain hose too hard, as it may break.
•
Before passing the drain hose through the hole, wrap it with
insulation to keep it from possible damage.
•
The copper pipe and the drain hose must be wrapped with
piping wrap.
•
The insulation pad (underlay) should be used where the pipe contacts the wall.