YMGI Group will not be responsible for any personal injury or any property damage caused by 
improper or incorrect installation, improper service or maintenance or by not following the 
instructions listed in this manual.
 
 

DO NOT

 pull on the power supply cords or refrigeration lines that are connected to the indoor and 

outdoor units. Install the power supply cords and secure them into position. PVC line set cover is 
recommended for the outdoor unit to protect against rain, sunlight and accidental damage.  

 
DO NOT

 allow cold air to blow directly onto people for a prolonged period, as this could make people 

cold and uncomfortable.  

 

DO NOT

 undersize any of the power supply wires.  

 

DO NOT

 connect several units to a single breaker. Don't undersize or oversize the circuit breaker. A 

poorly sized circuit breaker can cause unit failure and even fire. 

 

DO NOT

 wire or open a unit while the unit is running. Make sure to disconnect the power supply and 

switch off all circuits prior to inspecting or servicing the unit.

 

Inspecting and servicing the unit while the 

power supply is connected, and the circuits are switched on could cause an electrical shock or fire. 

 

DO NOT

 install the indoor unit near any cooking surfaces, in direct sunlight or any ventilation systems. 

Poor placement could decrease efficiency and waste energy.        

 

DO NOT

 install the unit in places where there is exposure to flammable materials or gas.  

 

DO NOT

 apply chemical solvents, flammable insecticides, or abrasive materials directly on the unit. 

Clean the unit only with a soft dry cloth. 

 

DO NOT

 install the unit in a damp laundry room or near flammable gas. All units must be protected by a 

certified electrical circuit breaker in accordance with all safety and electrical codes. 

 

DO NOT

 use the system for anything other than what it was designed.  

 

DO NOT

 store or install the units near food, paint, or other chemicals. 

 

DO NOT

 use the unit in cool or dry mode for prolonged periods where humidity is higher than 90%. 

 

DO NOT

 operate the unit for prolonged periods without refreshing ambient air. Open a door or window 

periodically to allow in fresh air. 

 

 
NOTE TO OWNER 

Keep these instructions for future reference. Be sure to write down the model and serial number of unit 
on space provided on back page. The model and serial number can be located on the serial number 
plate attached to unit. These numbers are required for service. 
 

 

 

 

 

Содержание TTWA Series

Страница 1: ...ded by YMGI Failure to follow and adhere to all codes and documentation can cause damage to equipment property even personal injury Installer Currently licensed certified HVAC technicians only Must Re...

Страница 2: ...s and LCDI Cords 17 Installation Instructions 18 Wall Sleeve Assembly 19 Outdoor Grille Installation 20 Vent Control and Air Direction 22 Maintenance and Cleaning 24 Wiring 25 Unit Features 26 Operati...

Страница 3: ...the wall installation in new or existing buildings To complete the installation of this TTWA an insulated wall sleeve and an outdoor grille either the stamped aluminum grille or the architectural gril...

Страница 4: ...ing and recycling of certain refrigerants the equipment and tools necessary to perform these service procedures In addition some states or municipalities may have additional requirements that must als...

Страница 5: ...soon as possible and provide the following information Data on the unit model number serial number and owner s name A detailed description of the unit s problem before and after the problem occurred...

Страница 6: ...equire certified and licensed personnel to install Reading and following YMGI Group recommendations and requirements contained in the following pages and other documents is the first step to help ensu...

Страница 7: ...through any structures at time of installation 2 Not installing an oil P trap in the copper suction line where the indoor unit is located 18 feet or more below the outdoor unit 3 Cross piping and or...

Страница 8: ...date from YMGI Group whichever comes first This is a standard limited liability warranty and DOES NOT cover the following Any damage or repairs to properties or persons as an incident of or consequen...

Страница 9: ...ill ground ship out the parts ASAP Expedited shipping is available at the customer s expense 4 Replacement parts that have an approved warranty registration are to be warranted for the remainder of th...

Страница 10: ...YMGI Your Modern Green Idea 10...

Страница 11: ...not set the indoor unit s room temperature too low Keeping the temperature difference between indoor and outdoor unit within 41 5 18 YMGI Group recommends that only properly trained and authorized pe...

Страница 12: ...ected and the circuits are switched on could cause an electrical shock or fire DO NOT install the indoor unit near any cooking surfaces in direct sunlight or any ventilation systems Poor placement cou...

Страница 13: ...8 3 9 9 7 4 9 3 9 4 9 Locked rotor Amp LRA A 23 8 41 5 21 54 28 5 21 28 5 Capacitor uF 35 60 30 60 40 30 40 Indoor fan motor Model YDK 30B 6P2 YDK 30B 6P2 YDK 30B 6P2 YDK 30B 6P2 YDK 30B 6P2 YDK 30B 6...

Страница 14: ...ts 34 U 36 U 36 U 34 U 34 U 36 U 34 U Outdoor sound level sound pressure level Cooling dB A 67 64 67 64 67 64 67 64 67 64 67 64 67 64 Unit Dimension W D H In 26 x 21 57 x 15 59 26 x 21 57 x 15 59 26 x...

Страница 15: ...t RLA A 7 8 2 9 3 9 4 9 Locked rotor Amp LRA A 41 5 15 21 28 5 Capacitor uF 60 20 30 40 Indoor fan motor Model YDK 30B 6P2 YDK 30B 6P2 YDK 30B 6P2 YDK 30B 6P2 Input W 64 64 64 64 Output W 30 30 30 30...

Страница 16: ...sound pressure level Cooling dB A 67 64 67 64 67 64 67 64 Unit Dimension W D H In 26 x 21 57 x 15 59 26 x 21 57 x 15 59 26 x 21 57 x 15 59 26 x 21 57 x 15 59 Packing W D H In 30 12 x 24 8 x 18 9 30 12...

Страница 17: ...n of this product Refer to the data specification plate for electrical requirements LCDI Cords Underwriters Laboratories and the National Electric Code NEC now require power cords that can sense curre...

Страница 18: ...Code The proper installation of this unit is described in the following sections Following the steps in the order presented should ensure proper installation HIGH VOLTAGE DISCONNECT ALL POWER BEFORE S...

Страница 19: ...ion In order for condensate water to drain properly inside the unit the sleeve must be installed properly Level from right to left A slight downward pitch from the indoor side to the outdoor side as s...

Страница 20: ...ineer and confirm that the new chassis can be used with the non standard specialized grille An improper outdoor grille may cause poor cooling or heating effect a higher power input and shorten the uni...

Страница 21: ...sis part of the way into the sleeve and reattach the ground wire back to the hole on the right side on the control panel area next to the ground symbol 3 Remove shipping pads inside air conditioner ne...

Страница 22: ...ocated behind the front grille on the right side of the air discharge area When set at CLOSE only the air inside the room will be circulated and conditioned When set at OPEN some inside air is exhaust...

Страница 23: ...NOTES 1 The unit is equipped with a rubber grommet mounted compressor These grommets are set at the factory and do not need to be adjusted 2 Check if there are any obstruction before the indoor and ou...

Страница 24: ...ecessary to remove the front panel 2 Filter is removed by opening the grille panel and gently pulling forward Vent Screen Before cleaning the vent screen disconnect power to the unit by unplugging the...

Страница 25: ...FIRST OPENING ALL DISCONNECTS AND OR REMOVING THE UNIT CORD SET PLUG FROM THE WALL OUTLET TO AVOID THE RISK OF ELECTRIC SHOCK PERSONAL INJURY OR PROPERTY DAMAGE DO NOT USE AN EXTENSION CORD WITH THIS...

Страница 26: ...sensors to maximize comfort conditions for the room occupant and provide outstanding features Thermistors are used to sense small changes in temperature and allow the microprocessor to monitor and re...

Страница 27: ...YMGI Your Modern Green Idea 27 OPERATING INSTRUCTIONS...

Страница 28: ...troduction of LCD screen icons Mode display Temperature display Timer display Range can be set between 16 32 C or 61 90 F TIMER ON is set Cooling mode TIMER OFF is set Fan mode Other display icons Hea...

Страница 29: ...GY SAVER button the green LED indicator turns off 1 Reset Filter means the indoor fan has been running for 250 hours accumulated It is time to clean the filter After finishing cleaning press this butt...

Страница 30: ...ller it could be used for the air conditioners with multifunction For some functions that the model doesn t have if press the corresponding button on the remote controller the unit will keep the origi...

Страница 31: ...through the power press ON OFF button on the remote controller to turn on the air conditioner 2 Press MODE button to select your required mode 3 Press or button to set your required temperature 4 Pres...

Страница 32: ...reaches 13 C 55 F will heating stop 6 Electric Power Off Memory When the power is turned on the unit will operate using the same settings as before power off The default setting is enabled UP 7 Clean...

Страница 33: ...ets the operational mode of the fan In ON position the fan will run continuously whenever power is applied in this mode In AUTO position the fan will cycle on and off with the compressor or electric h...

Страница 34: ...the unit that block the room return air flow if so remove the obstacle 2 Check the indoor fan make sure it is running properly if not repair the fan 3 Check the related sensor plug make sure that it...

Страница 35: ...t restricting or blocking unit airflow Reset to a lower or higher temperature setting Remove and clean filters Allow sufficient amount of time for unit to heat or cool the room Start heating or coolin...

Страница 36: ...7 524 1 00 4 00 122 0 2 096 2 138 2 180 3 34 1 66 23 0 16 090 16 431 16 733 1 04 3 96 123 8 2 030 2 071 2 112 3 37 1 63 24 8 15 418 15 739 16 060 1 07 3 93 125 6 1 966 2 006 2 047 3 41 1 59 26 6 14 77...

Страница 37: ...YMGI Your Modern Green Idea 37 TTWA Wiring Diagrams TTWA0 Wiring Diagram AC Only...

Страница 38: ...YMGI Your Modern Green Idea 38 TTWA0 Wiring Diagram AC Heater...

Страница 39: ...YMGI Your Modern Green Idea 39 TTWA0 Wiring Diagram HP...

Страница 40: ...YMGI Your Modern Green Idea 40 TTWA0 Wiring Diagram HP Heater...

Страница 41: ...1 USER NOTES AND INSTALLATION SERVICE MAINTENANCE NOTES INSTALLATION NOTES Put down any questions comments or problems you have experienced as a unit history No Date Notes Asked Technician for Help Di...

Страница 42: ...dea 42 USER NOTES Put down whatever questions you have or problems you have seen as a unit history No Date Company Name Technician Name Phone HVAC License Job Not Performed by Technician Technician Ch...

Страница 43: ...YMGI Your Modern Green Idea 43 SERVICE MAINTENANCE NOTES No Date Service Maintenance Company Name Technician Name Phone HVAC License...

Страница 44: ...tu h 58 4 78 1 Single Zone 18 23 SEER 09 36K Btu h Symphony CHOIR DC Inverter 59 2 DC Inverter Multiple Zone 16 SEER 2x09K to 5x12K Btu h 59 2S DC Inverter Multiple Zone 16 SEER 6x09K to 9x09K Btu h 5...

Отзывы: