Yingli Solar PV Modules, Installation and User Manual 

page 7

The information in this supplement is believed to be reliable, but does not constitute an expressed or implied warranty. Yingli Solar reserves the right to make 
changes to its PV modules and other products, their specifications, or this supplement without prior notice.

This supplement to the installation manual does not contain information about some older module series no longer being manufactured by Yingli Solar. If you 
require information about such modules, please contact Yingli Solar.

This supplement refers to modules of the following types:

Table 1: Module types

E L E C T R I C A L   C H A R AC T E R I S T I C S

Nameplate ratings are average values. The electrical characteristics are /- 10 percent of the indicated values of Isc, Voc, and Pmax under Standard Test 
Conditions (irradiance of 1000 W/m

2

, AM 1.5 spectrum, and a cell temperature of 25°C). Refer to module datasheets for specific power output tolerances. Please 

refer to Table 1 to see which power classes actually exist for which module series. 

YINGLI SOLAR PV MODULES 

Module Supplement

Revision date 

Nov. 17, 2020

  |  Applicable for IEC certified products.

File name: Corporate Logo with Tagline / Vertical.ai

FAMILY

YLM 120 Cell

half Cell

YLM 120 Cell

half Cell 1500V

YLM 144 Cell 

half Cell

YLM 144 Cell 

half Cell 1500V

TYPE

YL365D-34d 1/2

YL365D-34d 1500V 1/2  

YL435D-40d 1/2

YL435D-40d 1500V 1/2

YL370D-34d 1/2

YL370D-34d 1500V 1/2

YL440D-40d 1/2

YL440D-40d 1500V 1/2

YL375D-34d 1/2

YL375D-34d 1500V 1/2

YL445D-40d 1/2

YL445D-40d 1500V 1/2

YL380D-34d 1/2

YL380D-34d 1500V 1/2 

YL450D-40d 1/2

YL450D-40d 1500V 1/2

YL455D-40d 1/2

YL455D-40d 1500V 1/2

YL460D-40d 1/2

YL460D-40d 1500V 1/2

Содержание YL365D-34d 1/2

Страница 1: ...n laboratory This Installation and User Manual is available in different languages In cases of discrepancy between versions the English language version shall control Failure to comply with the requir...

Страница 2: ...g so may degrade performance or cause irreparable damage and will void any applicable warranties If it is necessary to store PV modules prior to installation the PV modules should remain inside the pa...

Страница 3: ...that are approved for use at the maximum short circuit current of the PV module Yingli Solar recommends installers use only sunlight resistant cables qualified for direct current DC wiring in PV syst...

Страница 4: ...corrosion An addendum to UL Standard 1703 Flat Plate Photovoltaic Modules and Panels recommends metal combinations not exceed an electrochemical potential difference of 0 5 Volts The frame rails have...

Страница 5: ...0 cell module is mounted with four inner holes and the 144 cell module is mounted with four outer holes with max mechanical loads of 5400 Pa snow front and 2400 Pa wind back Top down Clamps Third part...

Страница 6: ...wiring as this presents a shock hazard Clean the glass surface of the PV modules with a soft brush using soft clean water PH6 9 with a recommended pressure less than 690kPa which is typical of most m...

Страница 7: ...cent of the indicated values of Isc Voc and Pmax under Standard Test Conditions irradiance of 1000 W m2 AM 1 5 spectrum and a cell temperature of 25 C Refer to module datasheets for specific power out...

Страница 8: ...E SERIES WITH 35MM FRAME CONT UNITS mm YLM 120 Cell half Cell also valid for YLM 120 cell half cell 1500V Frame Cross Section Legend Legend Grounding holes Mounting holes Drainage holes Mounting toler...

Отзывы: