page 2

De-energize PV modules by removing them entirely from light or by

 

covering 

their front surface with an opaque material. Regard the safety regulations for 
live electrical equipment when working with modules that are exposed to any 
light. Use insulated tools and do not wear metallic

 

jewelry while working with 

PV modules.

In order to avoid arcing and electrical shock, do not disconnect electrical 
connections under load. Faulty connections can also result in arcing and 
electrical shock. Keep connectors dry and clean, and ensure that they are in 
proper working condition. Never insert metallic objects into the connectors, or 
modify them in any way in order to secure an electrical connection.

Do not touch or handle PV modules with broken glass, separated frames or 
a damaged backsheet unless the PV modules are first disconnected and you 
are wearing proper PPE. Avoid handling PV modules when they are wet unless 
cleaning the PV modules as directed in this manual. Never touch electrical 
connections that are wet without protecting yourself with insulated gloves.

Transport and Handling

Yingli Solar PV modules must be transported in the supplied packaging only and 
kept in the packaging until they are ready to be installed. Protect pallets against 
movement and exposure to damage during transportation. Secure pallets from 
falling over. Do not exceed the maximum height of pallets to be stacked, as 
indicated on the pallet packaging. Store pallets in a cool and dry location until 
the PV modules are ready to be unpackaged.

Figure 2: Pallet of PV modules

Yingli Solar PV modules are heavy, and should be handled with care. PV modules 
shall be handled at the frame; never use the junction box or cables as a grip. Do 
not exert mechanical stress on the cables. Never step on PV modules or drop 
or place heavy objects on them. Be careful when placing PV modules on hard 
surfaces, and secure them from falling. Broken glass can result in personal injury. 
PV modules with broken glass cannot be repaired and must not be used. Broken 
or damaged PV modules must be handled carefully and disposed of properly.

For unpacking PV modules from the Yingli Solar supplied packaging, first remove 
the pallet lid (after removing securing straps, if provided). Remove PV modules 
one at a time by sliding them up the channel in the package (see Figure 3). You 
may need to secure the remaining PV modules in the pallet packaging to prevent 
them from falling over. 

 
 

Figure 3: Removing PV modules from a pallet

Check PV modules for damage due to transportation before they are installed; 
do not install damaged modules. Contact the company you purchased the Yingli 

Solar PV modules from in order to obtain information on making claims for 
defective PV modules. 

PV module surfaces are susceptible to damage that could affect the performance 
or safety of the PV module; do not damage or scratch the PV module surfaces, 
and do not apply paint or adhesive to any of the surfaces, including the frame. 
For your safety, do not disassemble or modify Yingli Solar PV modules in any 
way. Doing so may degrade performance or cause irreparable damage and will 
void any applicable warranties. 

If it is necessary to store PV modules prior to installation, the PV modules 
should remain inside the packaging and protected from exposure that could 
compromise the durability of the packaging. 

Fire

Yingli Solar PV Modules have a Class C fire resistance rating in accordance with 
the IEC 61730-2 certification. When PV modules are mounted on rooftops, the 
roof must have a fire resistant covering suitable for this application. PV modules 
are electrical generating devices that may affect the fire safety of a building.

The use of improper installation methods and/or defective parts may result 
in the unexpected occurrence of an electrical arc during operation. In order to 
mitigate the risk of fire in this event, PV modules should not be installed near 
flammable liquids, gases, or locations with hazardous materials. 

In the event of a fire, PV modules may continue to produce a dangerous voltage, 
even if they have been disconnected from the inverter, have been partly or 
entirely destroyed, or the system wiring has been compromised or destroyed. In 
the event of fire, inform the fire crew about the particular hazards from the PV 
system, and stay away from all elements of the PV system during and after a fire 
until the necessary steps have been taken to make the PV system safe.

A P P L I C AT I O N   I N F O R M AT I O N

Application Restrictions

Yingli Solar PV modules must be mounted on appropriate mounting structures 
positioned on suitable buildings, the ground, or other structures suitable for PV 
modules (e.g. carports, building facades or PV trackers). PV modules must not 
be mounted on moving vehicles of any kind. Yingli Solar PV modules must not 
be installed in locations where they could be submerged in water. 

Yingli Solar PV modules must not be sited in locations where aggressive 
substances such as salt or salt-water, or any other type of corrosive agent, could 
affect the safety and/or performance of the PV modules. Although some types 
of Yingli Solar PV modules have passed the IEC 61701 salt-mist corrosion test 
with a salt concentration of 5% by weight, galvanic corrosion can occur between 
the aluminum frame of the PV module and mounting or grounding hardware if 
such hardware is comprised of dissimilar metals. Yingli Solar recommends that 
only stainless steel and aluminum metal directly contact PV modules in seaside 
installations to limit corrosion. 

Artificially concentrated light must not be directed on Yingli Solar PV modules. 

Design Recommendations

Yingli Solar recommends that PV modules be mounted at a minimum tilt angle 
of 10 degrees to allow for proper self-cleaning from normal rain showers.

Partial or complete shading of a PV module or modules can significantly reduce 
system performance. Yingli Solar recommends minimizing the amount of shade 
throughout the year to increase the amount of energy produced by the PV 
modules.

Lightning protection is recommended for PV systems that are to be installed in 
locations with high probability of lightning strikes.

High system voltages could be induced in the event of an indirect

 

lightning 

strike, which could cause damage to PV system components.

 

The open area of 

wire loops should be minimized, as shown in Figure 4,

 

in order to reduce the risk 

Содержание YL365D-34d 1/2

Страница 1: ...n laboratory This Installation and User Manual is available in different languages In cases of discrepancy between versions the English language version shall control Failure to comply with the requir...

Страница 2: ...g so may degrade performance or cause irreparable damage and will void any applicable warranties If it is necessary to store PV modules prior to installation the PV modules should remain inside the pa...

Страница 3: ...that are approved for use at the maximum short circuit current of the PV module Yingli Solar recommends installers use only sunlight resistant cables qualified for direct current DC wiring in PV syst...

Страница 4: ...corrosion An addendum to UL Standard 1703 Flat Plate Photovoltaic Modules and Panels recommends metal combinations not exceed an electrochemical potential difference of 0 5 Volts The frame rails have...

Страница 5: ...0 cell module is mounted with four inner holes and the 144 cell module is mounted with four outer holes with max mechanical loads of 5400 Pa snow front and 2400 Pa wind back Top down Clamps Third part...

Страница 6: ...wiring as this presents a shock hazard Clean the glass surface of the PV modules with a soft brush using soft clean water PH6 9 with a recommended pressure less than 690kPa which is typical of most m...

Страница 7: ...cent of the indicated values of Isc Voc and Pmax under Standard Test Conditions irradiance of 1000 W m2 AM 1 5 spectrum and a cell temperature of 25 C Refer to module datasheets for specific power out...

Страница 8: ...E SERIES WITH 35MM FRAME CONT UNITS mm YLM 120 Cell half Cell also valid for YLM 120 cell half cell 1500V Frame Cross Section Legend Legend Grounding holes Mounting holes Drainage holes Mounting toler...

Отзывы: