background image

Y I N G L I S O L A R .CO M

©

 Yingli Energy Development Company Limited           

GB Modules Installation and User Manual  Page 1 

This manual applies to photovoltaic modules (“PV modules”, 
also commonly known as solar panels) manufactured by Yingli 
Energy  Development  Company  Limited  (“Yingli  Solar”),  and 
is  explicitly  written  for  qualified  professionals  (“Installer”  or 
“Installers”),  including  without  limitation  licensed  electricians 
and RAL Certified PV Installers.

I N T R O D U C T I O N

Thank  you  for  choosing  Yingli  Solar  as  your  PV  module  provider.  We 

appreciate  your  business!  This  manual  contains  important  information 

pertaining  to  the  electrical  and  mechanical  installation  and  maintenance 

of PV modules, and contains safety information that you must read carefully and 

be  familiar  with  before  handling,  installing,  and/or  maintaining  Yingli  Solar  PV 

modules.

Yingli Solar does not assume responsibility and expressly disclaims liability for 

losses, damages, or expenses arising out of, or in any way connected with this 

Installation  and  User  Manual.  Yingli  Solar  assumes  no  responsibility  for  any 

infringement  of  patents  or  other  rights  of  third  parties,  which  may  result  from 

using Yingli Solar PV modules. No license is granted expressly or by implication 

or under any patent or patent rights. The information in this manual is believed to 

be reliable, but does not constitute an expressed or implied warranty. Yingli Solar 

reserves the right to make changes to its PV modules and other products, their 

specifications, or this manual without prior notice.

Yingli  Solar  and  its  subsidiaries  are  not  liable  for  any  damages  caused  by 

inappropriate  installation,  use,  or  maintenance  of  Yingli  Solar  PV  modules, 

including  without  limitation  damages,  losses,  and  expenses  caused  by  non-

observance of the instructions of this manual or caused by or in connection with 

products of other manufacturers.

Yingli Solar PV modules are designed to meet the requirements for the standards 

IEC  61215

  and 

IEC  61730

,  application  class  A.  Modules  rated  for  use  in  this 

application  class  may  be  used  in  systems  operating  at  greater  than  50  V 

DC

 

or  240  W,  where  general  contact  access  is  anticipated.  Modules  qualified  for 

safety through 

IEC 61730-1

 and 

IEC 61730-2

 and within this application class are 

considered to meet the requirements for safety class II. In the course of the PV 

module certification process, the compliance of this manual with the certification 

requirements has been verified by an independent certification laboratory. 

This Installation and User Manual is available in different languages. In cases of 

discrepancy between versions, the English language version shall control.

Failure  to  comply  with  the  requirements  listed  in  this  manual  will  invalidate  the 

Limited Warranty for PV Modules as provided by Yingli Solar at the time of sale to 

the direct customer. Additional recommendations are provided to enhance safety 

practices and performance results. Please provide a copy of this manual to the 

PV system owner for their reference, and inform them of all relevant aspects of 

safety, operation and maintenance.

S A F E T Y

General 

You must understand and follow all applicable local, state, and federal regulations 

and  standards  for  building  construction,  electrical  design,  fire,  and  safety,  and 

must check with local authorities to determine applicable permitting requirements 

before attempting to install or maintain PV modules.

Rooftop  PV  systems  should  only  be  installed  on  dwellings  that  have  been 

formally analyzed for structural integrity, and confirmed to be capable of handling 

the additional weighted load of PV system components, including PV modules, by 

a certified building specialist or engineer. 

For your safety, do not attempt to work on a rooftop until safety 

precautions  have  been  identified  and  taken,  including  without 

limitation  fall  protection  measures,  ladders  or  stairways,  and 

personal protective equipment (PPE).

For your safety, do not install or handle PV modules under adverse conditions, 

including without limitation strong or gusty winds, and wet or frosted roof surfaces. 

The flat-plate PV module construction consists of a laminated assembly of solar 

cells encapsulated within an insulating material with a rigid glass surface and an 

insulated substrate. The laminated assembly is supported by an aluminum frame 

that is also used for installation the module. See Figure 1 for an illustration of the 

PV module components.

Figure 1: Module components and cross-section of the laminated assembly

Electrical

PV  modules  can  produce  current  and  voltage  when  exposed 

to light of any intensity. Electrical current increases with higher 

light  intensity.  DC  voltage  of  30  Volts  or  higher  is  potentially 

lethal.  Contacting  the  live  circuitry  of  a  PV  system  operating 

under light can result in lethal electric shock.

1

1. 

Aluminum Frame

2. Glass

3.  Encapsulating EVA

4.  PV Cell

5. Backsheet

2

3

5

4

YINGLI SOLAR GB MODULES

 

Installation and User Manual

Revision date: 

17

 May 2023  |  Applicable for IEC certified products  |  The second edition

Содержание PANDA 108CELL 182TOPCon

Страница 1: ...ication requirements has been verified by an independent certification laboratory This Installation and User Manual is available in different languages In cases of discrepancy between versions the Eng...

Страница 2: ...do not disassemble or modify Yingli Solar PV modules in any way Doing so may degrade performance or cause irreparable damage and will void any applicable warranties If it is necessary to store PV modu...

Страница 3: ...field wiring with suitable cross sectional areas that are approved for use at the maximum short circuit current of the PV module Yingli Solar recommends installers use only sunlight resistant cables...

Страница 4: ...not exceed an electrochemical potential difference of 0 5 Volts The frame rails have pre drilled holes marked with a grounding sign as illustrated in Figure 8 These holes should be used for grounding...

Страница 5: ...chment Figure 12 Installation rails The large size modules are mounted with four outer holes with max mechanical loads of 5400 Pa snow front and 2400 Pa wind back Top down Clamps Third party clamps th...

Страница 6: ...ve materials that could scratch or damage the glass surface Failure to comply with these requirements may adversely affect the PV module performance Yingli Solar PV modules are designed to withstand h...

Страница 7: ...1 2 xxx 405 430 YLxxxC 42e 1 2 xxx 450 480 Y L x x x C 4 2 e 1500V 1 2 xxx 450 480 YLxxxC 46e 1 2 xxx 495 525 Y L x x x C 4 6 e 1500V 1 2 xxx 495 525 YLxxxC 50e 1 2 xxx 540 575 Y L x x x C 5 0 e 1500V...

Страница 8: ...f 14 20 N m The tightening steps as follows use torque wrench to tighten nut to target torque nut loosen 90 180 degrees finally tighten the nut to the target torque and reduce the torque attenuation 2...

Страница 9: ...ashers of minimum 1 4 mm thickness with an minimum outer diameter of 15 57 mm Modules can be attached using the mounting holes the number of mounting holes used for a single long side frame 2 includin...

Страница 10: ...when it is pressed down L represents the length of the long side of the module the described distances are from the module edge to the middle of the clamp The long side frames of the module are fixed...

Страница 11: ...ules then remove the paper angles inside the box as shown in Figure 2 3 Cut the cardboard of one long side of the box then cut the inner packing belts around the modules and pallet as shown in Figure...

Страница 12: ...idth more than 1 5 m gantry can withstand more than 1 5 tons pressure The top of the gantry needs to be placed with cushioning material These transfer requirements apply to upright packaging modules N...