![YILKAR YK 120 S Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/yilkar/yk-120-s/yk-120-s_installation-instruction_3358025036.webp)
32
Fault Codes
Cause of Occurrence:
The cable may have been cut or the socket may have come off. The sensor
may be faulty or broken.
Device Response:
When an error occurs, the system shuts down and the error code is displayed on
the screen.
Troubleshooting:
*Check sensor cable and sockets.
*If there is no problem with cables and sockets; replace the sensor.
E 1 : Inside Temperature Sensor Open Circuit
Cause of Occurrence:
The cable may have been cut or the socket may have come off. The sensor
may be faulty or broken.
Device Response:
When an error occurs, the system shuts down and the error code is displayed on
the screen.
Troubleshooting:
*Check sensor cable and sockets.
*If there is no problem with cables and sockets; replace the sensor.
E 2 : Outside Temperature Sensor Open Circuit
21°
E 2
SET
Fault code
Supply Voltage
12 V - 24 V
Average Electrical Consumption
400 mA @12V @25C
Operating Temperature
- 10 C --- + 40 C
Table.5 Technical Information Table