Yichang Jiangjing Optoelectronic JT-E020 Скачать руководство пользователя страница 6

10.3  function description

10.3.1  The three display states are as follows

10.3.3 Setup:

     Long press the setting key for 3 seconds to enter the setting mode 

or exit the current setting mode; In the setting mode, short press the 

setting key to select the function option (f1-f2-f3-f4-f5),and press the 

"+" / "-" key to modify the parameters.

10.3.4 Measurement temperature unit please select (F1):

     In normal measurement mode, press the setting key for more than 

3 seconds until the LCD displays F1 option; Press "+" to select Celsius 

(

), press "-" to select Fahrenheit (

);Short press the setting key to 

save the current selection and enter the next option, long press 3 

seconds to save the current setting and exit the setting function. 

10.3.5 Warning threshold setting (the back-lit displays red color 
when the measurement exceeds this threshold):

     Press the setting key to select the LCD display as F2; Press the 

"+" / "-" key to modify the alarm temperature value (the lowest alarm 

is 37 

); Short press the setting key to save the current selection and 

enter the next option, long press 3 seconds to save the current setting 

and exit the setting function.

 10.3.2 Check the historical measurement temperature:

Normal 

Temperature

 Exceeding

Threshold

Article1

Article 20

Battery

Exhausted

08

09

Содержание JT-E020

Страница 1: ...20 Yichang Jiangjing Optoelectronic Co Ltd Manufacturer After sales service Yichang Jiangjing Optoelectronic Co Ltd After sales service Tel 86 0717 299555 Production Address No 66 Changning Third Road Maoping Town Zigui County Yichang City Hubei Province China ...

Страница 2: ...part is more affected by the ambient temperature 2 Use safety manual Please read this manual carefully before use The operating temperature of this product is 10 40 the optimal temperature is 25 Do not use this product in an environment above 40 or below 0 Do not place this product near charged objects to avoid electric shock Please do not use this product in an environment with relative humidity ...

Страница 3: ...an forehead It is widely used in home use This product cannot replace the diagnosis of doctors 7 LCD display description 5 Precautions Before Use Power On Self Test Aim at the measured object press the measurement switch the LCD will display all the numbers and characters of the self test and the self test screen appears This screen is displayed for about 1 second 6 Product Structure Model JT E020...

Страница 4: ...elative humility 93 Non corrosive gas well ventilated room The transportation requirements are stipulated in the order contract and the severe impact vibration and rain and snow splashing during transportation must be prevented 9 Technical index 9 1 Basic parameters 8 2 Product contraindications 1 Conditions such as birth defects congenital malformations septic shock and circulatory failure may se...

Страница 5: ...ve polarity when replacing the new battery Improper placement may cause damage to the product 4 Remove the battery when it has not been used for a long time to prolong its service life and prevent damage due to battery leakage 2 When the measurement switch is pressed the current measurement temperature value is displayed on the display and the measurement data can be automatically stored Note 1 Be...

Страница 6: ...select Fahrenheit Short press the setting key to save the current selection and enter the next option long press 3 seconds to save the current setting and exit the setting function 10 3 5 Warning threshold setting the back lit displays red color when the measurement exceeds this threshold Press the setting key to select the LCD display as F2 Press the key to modify the alarm temperature value the ...

Страница 7: ...biological comprehensive system Body temperature is an important data indicating whether human life activities are normal Usually we measure our health by measuring the temperature of the forehead cochlea anus mouth and armpit It is measured in different parts Body temperature will vary please refer to the table below for specific differences 10 3 7 Error correction settings Press the setting key ...

Страница 8: ... it has exceeded the measurement range or the temperature is higher than 42 9 in human temperature measurement mode 2 LCD display message Hi Using a non contact electronic body temperature timer the LCD displays the message Lo indicating that the measurement temperature is lower than the measurement range or the temperature is lower than 32 C in the human body temperature measurement mode 3 LCD di...

Страница 9: ...ference when using such as near mobile phones microwave ovens etc Guidelines and manufacturer s declarations are detailed in the attachment The equipment or system should not be used close to or stacked with other equipment If it must be used close to or stacked it should be observed to verify that it can operate normally in the configuration in which it is used 1 thermometer 1 manual 1 certificat...

Страница 10: ... immunity NOTE UT is the a c mains voltage prior to application of the test level The JT E020 is intended for use in the electromagnetic environment specified below The customer or the user of the JT E020 should ensure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Portable and mobile RF communications equipment shoul...

Страница 11: ... considered If the measured field strength in the location in which the JT E020 is used exceeds the applicable RF compliance level above the JT E020 should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the JT E020 b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m...