Limit position setting: 

1

.

 

A maximum of six different limit stop positions can be set. The furthest two 

positions are called the UP and DOWN limit stop positions. The others are 

called the middle limit stop positions;

2

.

 

When the first limit position is in the UP limit stop position (as below 

illustration), all other limit positions can only be set below this position; the 

same applies when setting the first DOWN limit stop position, all other limit 

stop positions can only be set above this position;

3

.

 

Every limit stop position can be fine-tuned or deleted separately (The first 

limit stop  position can only be fine-tuned but can’t be deleted separately. It 

can only be deleted by resetting the memory);

4

.

 

The motor will stop at the next limit stop position after accepting an UP/

DOWN instruction. When it reaches the UP limit stop position, any additional 

UP instruction is cancelled out; when it reaches the DOWN limit stop 

position, the DOWN instruction is also cancelled;

5

.

 

Pressing either the UP/DOWN button twice on the transmitter within 1 

second will instruct the motor to go directly to the UP/DOWN limit stop 

position without stopping at any middle limit stop.

The third limit stop position

The first limit stop position (Up limit position)

The third limit stop position

The third limit stop position

The second limit stop position

All the other 

limit positions 

can be set below 

the first limit 

position

Содержание 980001

Страница 1: ...yewdale co uk Part no 980001 Programming Instructions for YewdaleDefiant motor 980001 Programming Instructions forYewdaleDefiant motors 980001...

Страница 2: ...ceiver 980001 Programming Programme Button Change direction of travel if required Press PROG for 1 second Press STOP on the transmitter for 5 seconds Motor will shunt once Motor PROG Button Motor will...

Страница 3: ...t from the limit position preparation automatically If there s no other action within 30 seconds the motor will exit from the limit position preparation automatically Motor will shunt once to indicate...

Страница 4: ...position Press PROG for 1 second to save the limit position If there s no other action within 30 seconds the motor will exit from the limit position preparation automatically Press PROG for 1 second M...

Страница 5: ...d separately The first limit stop position can only be fine tuned but can t be deleted separately It can only be deleted by resetting the memory 4 The motor will stop at the next limit stop position a...

Страница 6: ...ll shunt once again The transmitter is stored Motor shunts once again Single channel has been deleted Delete all the memories Press STOP for 5 seconds After deleting all codes the motor will be restor...

Страница 7: ...k the components 2 The motor stops suddenly whilst running 1 Motor has exceeded overheating protection 130o C 2 Power was cut off 1 After the motor has cooled sufficiently motor will perform as requir...

Страница 8: ...infectioncontrol focus providing anall encompassingsolutionto increasedlevelsofdignity cubicle and track systems yewdale co uk seethingsdifferently Theindustry spreferred choiceofmaintenance freepriva...

Отзывы: