programming instructions  

Part no: 980001

4

Delete the limit stop position 

(please note: the first limit position can’t be deleted)

Let the motor run to the 

limit stop position that is to 

be deleted.

Press PROG for  

7 seconds.

Motor will shunt 

once to indicate limit 

setting mode.

Within 7 seconds the motor will 

shunt once again. The preset 

limt position is now cleared.

Limit position fine tuning: 

Adjust to the  

required position.

Press PROG for 1 second to save 

the limit position.

(If there’s no other action within 30 seconds. the motor will exit from the limit position preparation automatically)

Press PROG for 1 

second.

Motor will shunt once to 

indicate limit setting mode.

Let the motor run into the 

limit stop position that needs 

fine tuning.

Motor will shunt again. 

The fine tune setting has 

been saved.

Programming Instructions

YewdaleDefiant

®

 230v AC Tubular motor w/ Radio Receiver (980001)

Turn the motor off: 

Press PROG on the 

motor for 7 seconds.

Motor will beep and 

shunt once.

Motor will beep again after 

7 seconds. The motor has  

been turned off.

Содержание 980001

Страница 1: ...yewdale co uk Part no 980001 Programming Instructions for YewdaleDefiant motor 980001 Programming Instructions forYewdaleDefiant motors 980001...

Страница 2: ...ceiver 980001 Programming Programme Button Change direction of travel if required Press PROG for 1 second Press STOP on the transmitter for 5 seconds Motor will shunt once Motor PROG Button Motor will...

Страница 3: ...t from the limit position preparation automatically If there s no other action within 30 seconds the motor will exit from the limit position preparation automatically Motor will shunt once to indicate...

Страница 4: ...position Press PROG for 1 second to save the limit position If there s no other action within 30 seconds the motor will exit from the limit position preparation automatically Press PROG for 1 second M...

Страница 5: ...d separately The first limit stop position can only be fine tuned but can t be deleted separately It can only be deleted by resetting the memory 4 The motor will stop at the next limit stop position a...

Страница 6: ...ll shunt once again The transmitter is stored Motor shunts once again Single channel has been deleted Delete all the memories Press STOP for 5 seconds After deleting all codes the motor will be restor...

Страница 7: ...k the components 2 The motor stops suddenly whilst running 1 Motor has exceeded overheating protection 130o C 2 Power was cut off 1 After the motor has cooled sufficiently motor will perform as requir...

Страница 8: ...infectioncontrol focus providing anall encompassingsolutionto increasedlevelsofdignity cubicle and track systems yewdale co uk seethingsdifferently Theindustry spreferred choiceofmaintenance freepriva...

Отзывы: