![YET XtraDrive XD Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/yet/xtradrive-xd-series/xtradrive-xd-series_short-form-installation-manual_3315095033.webp)
Short Form Installation Guide
Installation Conditions of EMC Directive
33
7.
Installation Conditions of EMC Directive
The following conditions must be satisfied for a combination of SGM
%
H
servomotor and XtraDrive to comply EMC Directives (EN61000-6-2 and
EN55011, Group 1 Class A).
7.1. EMC Installation Conditions
This section describes the test installation conditions prepared by YET that
meet EMC guidelines for all XtraDrive models, including the standard type
(base mounted) and rack-mounted. The actual EMC level may differ
depending on the actual system’s configuration, wiring and other conditions.
7.2. Installation for Single- and Three-phase 200V XtraDrive(PC)
XD-P3-M
ٱ
to -30-M
ٱ
(30W to 3.0kW)
Represents option with PC connected to CN3 connector.
Note: Shielded Box with door closed
NOISE
FILTER
NOISE
FILTER
Brake Power
Supply
CL
A
M
P
CL
A
M
P
AC Power Supply
Single-phase
200V
or
Three-phase
200V
50/60Hz
U,
V
,W
L1, L2
L1C, L2C
CL
A
M
P
CL
A
M
P
CO
R
E
CO
R
E
CO
R
E
CO
R
E
CO
R
E
BRAKE
MOTOR
ENCODER
PE
CO
R
E
CO
R
E
Personal
Computer
PE
CN3
CN1
CN2
Ground Plate/ Shielded Box
Cable length
approx. 3m
XtraDrive
Mains Cable
Length
Approx. 2m
Cables
length
approx. 5m
4
2
3
1
Symbol Cable
Name
Specification
&
PC communication cable
Shielded cable
'
Servomotor cable
Shielded cable
(
Encoder cable
Shielded cable
)
AC line cable
Shielded cable
Содержание XtraDrive XD Series
Страница 2: ...Short Form Installation Guide Introduction 2...
Страница 9: ...Short Form Installation Guide Introduction 9 1 2 Warning Label...
Страница 24: ...Short Form Installation Guide Wiring 24 4 2 5 Three phase 200V Main Circuit...
Страница 26: ...Short Form Installation Guide Wiring 26 4 2 7 Three phase 400V Main Circuit...