![YET XtraDrive XD Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/yet/xtradrive-xd-series/xtradrive-xd-series_short-form-installation-manual_3315095019.webp)
Short Form Installation Guide
Wiring
19
The following table shows types of cables and must be used with the
previous tables for wire size specifications.
Cable Types
Symbol Name
Allowable Conductor
Temperature ºC
PVC
Normal vinyl cable
-
IV
600V vinyl cable
60
HIV
Temperature-resistant
vinyl cable
75
The following table shows appropriate cables for CN1 and CN2 XtraDrive
connectors.
Wire sizes were selected for three cables per bundle at 40ºC ambient
temperature with the rated current.
Connector Name
and Signal
Item Specification
Cable
Twisted-pair or shielded twisted-pair wire.
Applicable wire
AWG24 [0.2 mm
2
(0.0003 in
2
)], AWG26 [0.12 mm
2
(0.0002 in
2
)], AWG28 [0.08 mm
2
(0.0001 in
2
)],
AWG30 [0.05 mm
2
(0.00008 in
2
)].
Control
I/O Signal
Connector
CN1
Finished cable
dimension
Ø16.0 mm (Ø 0.63 in) MAX.
Cable Shielded
twisted-pair
wire.
Applicable wire
AWG24 [0.2 mm
2
(0.0003 in
2
)], AWG26 [0.12 mm
2
(0.0002 in
2
)], AWG28 [0.08 mm
2
(0.0001 in
2
)],
AWG30 [0.05 mm
2
(0.00008 in
2
)].
Use AWG22 [0.33 mm
2
(0.001 in
2
)] for encoder
power supply and AWG26 [0.12 mm
2
(0.0002 in
2
)]
for other signals. These conditions permit wiring
distances up to 20 m (65.6 ft).
PG Signal
Connector
CN2
Finished cable
dimension
Ø6.8 mm (Ø 0.27 in) MAX.
Содержание XtraDrive XD Series
Страница 2: ...Short Form Installation Guide Introduction 2...
Страница 9: ...Short Form Installation Guide Introduction 9 1 2 Warning Label...
Страница 24: ...Short Form Installation Guide Wiring 24 4 2 5 Three phase 200V Main Circuit...
Страница 26: ...Short Form Installation Guide Wiring 26 4 2 7 Three phase 400V Main Circuit...