Yes Falcon-II Скачать руководство пользователя страница 5

DISCLAIMER 

 
 

UNDER 

NO 

CIRCUMSTANCES 

W ILL 

CRITICAL 

ENVIRONMENT 

TECHNOLOGIES CANADA INC. (CETCI) BE LIABLE FOR ANY CLAIMS, LOSSES 
OR  DAMAGES  RESULTING  FROM  OR  ARISING  OUT  OF  THE  REPAIR  OR 
MODIFICATION  OF  THIS  EQUIPMENT  BY  A  PARTY  OTHER  THAN  CETCI 
SERVICE  TECHNICIANS,  OR  BY  OPERATION  OR  USE  OF  THE  EQUIPMENT 
OTHER  THAN  IN  ACCORDANCE  WITH  THE  PRINTED  INSTRUCTIONS 
CONTAINED  WITHIN  THIS  MANUAL  OR  IF  THE  EQUIPMENT  HAS  BEEN 
IMPROPERLY  MAINTAINED  OR  SUBJECTED  TO  NEGLECT  OR  ACCIDENT. 
ANY OF THE FORGOING WILL VOID THE WARRANTY.

 

 
 
 

REVISIONS 

 

 
THIS MANUAL WAS WRITTEN AND PUBLISHED BY CRITICAL  ENVIRONMENT          
TECHNOLOGIES 

CANADA 

INC. 

(THE 

MANUFACTURER). 

THE                    

MANUFACTURER 

MAKES 

NO 

WARRANTY 

OR 

REPRESENTATION,               

EXPRESSED 

OR 

IMPLIED 

INCLUDING 

ANY 

W ARRANTY 

OF                         

MERCHANTABILITY  OR  FITNESS  FOR  PURPOSE,  WITH  RESPECT  TO  THIS 
MANUAL.  ALL  INFORMATION  CONTAINED  IN  THIS  MANUAL  IS  BELIEVED  TO 
BE  TRUE  AND  ACCURATE  AT  THE  TIME  OF  PRINTING.  HOWEVER,  AS  PART 
OF  IT’S  CONTINUING  EFFORTS  TO  IMPROVE  IT’S  PRODUCTS  AND  THEIR 
DOCUMENTATION,  THE  MANUFACTURER    RESERVES  THE  RIGHT  TO  MAKE 
CHANGES  AT  ANY  TIME  WITHOUT  NOTICE.  REVISED  COPIES  OF  THIS 
MANUAL  CAN  BE  OBTAINED  BY  CONTACTING  CRITICAL  ENVIRONMENT 
TECHNOLOGIES CANADA INC.

 

 

SHOULD YOU DETECT ANY ERROR OR OMISSION IN THIS MANUAL, PLEASE  
CONTACT THE COMPANY AT THE FOLLOWING ADDRESS: 
 
CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC. 
UNIT 145, 7391 VANTAGE WAY 
DELTA, BC V4G 1M3 
CANADA 
 
TOLL FREE:  1-877-940-8741 
PHONE: 604-940-8741 
FAX: 604-940-8745 
E-MAIL: [email protected] 
WEBSITE: WWW.YESTEK.COM 
WEBSITE: WWW.CRITICAL-ENVIRONMENT.COM 
 
IN NO EVENT WILL CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC., 
OR IT’S OFFICERS OR  EMPLOYEES BE  LIABLE FOR ANY DIRECT, SPECIAL,          
INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES  RESULTING  FROM  ANY        
DEFECT  IN  ANY  MANUAL,  EVEN  IF  ADVISED  OF  THE  POSSIBILITY  OF  SUCH 
DAMAGES.

 

 
 
 

 

Содержание Falcon-II

Страница 1: ...ay Delta BC V4G 1M3 Canada Phone 604 940 7007 Fax 604 940 7044 www yestek com REV A JUNE 2 2008 Falcon II Next Generation Air Quality Monitor CO2 Temperature OPERATION MANUAL Critical Environment Tech...

Страница 2: ...2...

Страница 3: ...IP FOR A PERIOD OF EIGHTEEN MONTHS INCLUDING CO2 SENSOR FROM THE DATE OF PURCHASE BY THE ORIGINAL OWNER IF THE PRODUCT SHOULD BECOME DEFECTIVE WITHIN THIS WARRANTY PERIOD WE WILL REPAIR OR REPLACE IT...

Страница 4: ...LIABILITY REASONS CETCI HAS A POLICY OF PERFORMING ALL NEEDED REPAIRS TO RESTORE THE INSTRUMENT TO FULL OPERATING CONDITION PRIOR TO SHIPPING EQUIPMENT TO CETCI CONTACT OUR OFFICE FOR AN RMA RETURNED...

Страница 5: ...S MANUAL ALL INFORMATION CONTAINED IN THIS MANUAL IS BELIEVED TO BE TRUE AND ACCURATE AT THE TIME OF PRINTING HOWEVER AS PART OF IT S CONTINUING EFFORTS TO IMPROVE IT S PRODUCTS AND THEIR DOCUMENTATIO...

Страница 6: ...E 7 1 0 GENERAL 8 2 0 SPECIFICATIONS 8 9 3 0 DIMENSIONS 10 4 0 INSTRUMENT FEATURES 11 12 5 0 OPERATION 13 5 1 OPERATING MODES 13 5 2 DETAILED OPERATING INSTRUCTIONS 13 16 5 22 OPERATION MODE ADJUSTMEN...

Страница 7: ...mory The instrument may be hand held or will easily stand on a flat surface The FALCON II instruments are manufactured to provide good value to the end user Calibration and repair is available at our...

Страница 8: ...wall configuration only Power Requirement 160 mA Peak 15 mA average from 6V Outputs Normally Low 100mA max 24 VDC Adjustable set point factory setting is 1000ppm hysteresis is 50ppm One RJ 45 Connecto...

Страница 9: ...er C or 2 ppm per C whichever is greater referenced to 25 C Pressure Dependence 0 13 of reading per mm Hg Corrected via user input for altitude Response Time 2min for 63 of step change Warm Up Time 60...

Страница 10: ...10 3 0 DIMENSIONS 6 50 165mm 3 19 81 1mm 0 96 24 3mm...

Страница 11: ...INSTRUMENT FEATURES FUNCTION PUSH BUTTONS MODE UP DOWN ENTER left to right ON OFF PUSH BUTTON LED INDICATOR LCD DISPLAY TEST GAS INLET OPENING FLIP DOWN STAND ALKALINE BATTERY ACCESS DOOR WALL ADAPTER...

Страница 12: ...12 4 0 INSTRUMENT FEATURES CONT D Changing Alkaline Batteries...

Страница 13: ...d ALARM Alarm when CO2 concen tration exceeds one threshold alarm Alarm level can be changed through the keypad menu The audible alarm can be switched on off through the keypad menu when the speaker i...

Страница 14: ...go through the following sequence Temp C Temp F Vent Rate lps Vent Rate cfm p NOTE lps refers to Liter Per Second Per Person cfm p refers to Cubic Feet Per Minute Per Person 5 22 OPERATION MODE ADJUST...

Страница 15: ...e Mode button until OUTSIDE flashes 3 2 Press Enter to show OUTSIDE CO2 and PPM flashes Press Up Down to adjust the reading 3 3 Press the Enter save the setting and return to the User Mode After modif...

Страница 16: ...adings since the instrument was last switched on 6 1 Press the Mode button until MAX MIN flashes 6 2 Press Enter button MAX and MIN CO2 reading shows alternating 6 3 CLR will flash if press Up Down Pr...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Отзывы: