Using the OSICS SWT APC Module
168
OSICS User Manual
•
INTERNAL designates the internal modulation source of the T100 or ECL
modules.
•
MAINFRAME designates the OSICS Mainframe modulation source, which can be
internal or external.
The SWT APC
Unit Setup
menu is automatically displayed and the modulation
source is set for all the T100 and ECL modules connected to the SWT APC.
•
If you have selected INTERNAL, set the frequency of the individual T100 and ECL
modules using the
Set Frequency
sub-menu of the module setup menus (as
explained in the corresponding module sections).
•
If you have selected MAINFRAME, configure the wanted mainframe modulation
as explained in the T100 and ECL module sections.
12.10.2 Controlling the Modulation of All Connected T100 and ECL
Modules
Subject
From the OSICS SWT APC, you can control the modulation of all T100 and ECL modules
connected to the SWT APC. To achieve this, the modulation source and frequency must
be set for all modules.
Before Starting
•
Set the wanted modulation source for all T100 and ECL modules connected to the
SWT APC, as explained in section
Defining the Modulation Source for All Connected
, or directly from the setup menu of the modules.
•
Set the wanted modulation frequency for each connected module using the
Set
Frequency
sub-menu of the module
Unit Setup
menu or of the OSICS Mainframe
Main Setup
menu, depending on the selected modulation source.
Procedure
1.
Access the SWT APC
Unit Setup
menu (see section
Accessing an OSICS Module Setup
).
2.
Expand the
Modulation
menu and enter the
Control
sub-menu.
The
Modulation
control
sub-menu appears and displays the current state of the
modulation control.
Figure 124: SWT APC Unit Setup – Modulation Control (On)
3.
Turn the rotary knob to put the cursor before the wanted modulation:
•
ON
for standard modulation.
•
ON INVERTED
for reverse modulation
Main
EXIT
1
2
3
4
5
6
7
8
Unit Setup - Modulation control
ESCAPE
▲
Modulation control :
OFF
ON
Select a new value.
ON INVERTED
Содержание OSICS
Страница 2: ......
Страница 6: ...About This Manual 6 OSICS User Manual...
Страница 28: ...Installing and Connecting the OSICS Multifunction Platform 28 OSICS User Manual...
Страница 56: ...Using the OSICS ATN HP Module 56 OSICS User Manual BKR TLS 50 ATN DFB ECL T100 SLD SWT TLS AG SWT APC MAIN...
Страница 64: ...Using the OSICS BKR Module 64 OSICS User Manual BKR TLS 50 ATN DFB ECL T100 SLD SWT TLS AG SWT APC MAIN...
Страница 98: ...Using the OSICS DFB Module 98 OSICS User Manual BKR TLS 50 ATN DFB ECL T100 SLD SWT TLS AG SWT APC MAIN...
Страница 136: ...Using the OSICS SLD Module 136 OSICS User Manual BKR TLS 50 ATN DFB ECL T100 SLD SWT TLS AG SWT APC MAIN...
Страница 248: ...Certification and Compliance 248 OSICS User Manual...