![Yenen 38100090 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/yenen/38100090/38100090_installation-and-maintenance-manual_3275602005.webp)
Page 5 of 6
14.06.2011
SHOF-10-e
Rev Nr:1
Replacing top shear section
1- Disconnect the power to the dispenser and pump and lock the switch.
2- Close the valve manually and drain the system.
3- Remove the pipe or fitting from the top of the valve. The body does NOT have to be removed.
4- Remove the 3 bolts with a 6 mm Allen and lift damaged top out of body. Remove the o-ring.
5- Install a new o-ring and then the new top. Replace the 3 bolts and tighten.
6- Reattach the pipe or fitting and test the system for leaks.
7- Connect the power to the dispenser and the pump.
Types of Yenen shut-off valves
Part no
Dispenser connection *
Pipe connection *
Poppet
38100090
1½” Rp
2” BSPT Male
Double
38104090
1½” Rp
1½” BSPT Female
Double
38104190
1 ½” Rp
1½” BSPT Male
Double
38100890
1 ½” Rp
2” BSPT Male
Single
38101390
1 ½” Rp
1 ½” BSPT Female
Single
38101290
1 ½” Rp
1 ½” BSPT Male
Single
* Other types of threaded connections can be specially produced upon request.
Spare part kits
Part no
Part name
35011090
Upper body with poppet
35012090
Upper body without poppet