Master and slave: select one machine as master,
press the menu to choose the
function you want. Press other machines’ address to be DMX state. Use signal
cable to connect machines one by one. Then slave machines will run the same as
master machine.
Use controller to control lot of machines: if all machines are set the same menu
data, or different menu data, after use signal cable to connect to controller, all
machines will be controlled by controller. (before connect to controller, all
machines should be in the same channel mode 5ch or 9ch).
ATTENTION:
Section 3. Troubleshooting
Problem
Probable Cause(s)
Remedy
No power to fixture
Check power cables
Primary fuse blown
Replace fuse
No response from
fixture when power
is applies
Secondary
fuse
blown
Replace fuse
Controller
not
connected
Connect controller
Incorrect
addressing of the
fixtures
Check address setting on fixture and controller
Bad
data
link
connection
Inspect cables and correct poor connections
and/or broken cables.
Conflict
between
tracking and vector
control
Eliminate scene cross-fade on controller
Fixture resets but
does not respond
correctly
to
controller(DMX
mode operation)
Data
link
not
terminated
Insert termination plug in output of last fixture
Defective fixture or
2
devices
transmitting on link
Bypass fixtures one at a time until normal
operation is regained: unplug both connectors
and connect them directly together
Colors cannot be
mixed
Random
color
mixing is on
Turn off random color mixing
Fixture does not
reset correctly
Electronic
or
mechanical failure
Contact service technician
Lamp missing or
blown
Disconnect fixture and replace lamp
No light, lamp cuts
out intermittently, or
burns out too
quickly
Fixture or lamp is
too hot
Allow fixture to cool. If problem persists,
contact service technician
Section 4. Reference
Control Menu
DMX Protocol
Specification
Control Menu
No.
Menu
Function Specification
(
Press” ENTER”
)
1
R
---
r000 to r255 : from dark to bright
2
G— —
g000 to g255: from dark to bright
3
B
---
b000 to b255: from dark to bright
4
N
---
n000 to n255: from dark to bright
The 4 color’s
different
brightness
can mix out
all kinds of
color
5
C
---
C000 to C255
:
7 color shade speed
,
from
slow to fast
6
J
---
J000 to J255
:
7 color skip speed
,
from
slow to fast
。
Maximum 8PCS fixtures connected by Daisy chain connection.