Cable Connectors
Cables must have a male XLR connector on one end and a female XLR connector on the other end.
A word on termination: DMX is a resilient communication protocol, however
errors still occasionally occur. Termination reduces signal errors, and therefore best practices include
use of a terninator in all circumstances. If you are experiencing problems with erratic fixture behavior,
especially over long signal cable runs, a terminator may help improve performance.
To build your own DMX Terminator: Obtain a 120-ohm, 1/4-watt resistor, and
wire it between pins 2&3 of the last fixture. They are also readily available from specialty retailers.
Master and slave: select one machine as master,
press the menu to choose the function
you want. Press other machines’ address to be DMX state. Use signal cable to connect
machines one by one. Then slave machines will run the same as master machine.
Use controller to control lot of machines: if all machines are set the same menu data, or
different manual data, after use signal cable to connect to controller, all machines will be
controlled by controller. (before connect to controller, all machines should be in the same
channel mode 5ch or 2ch).
Section 3. Troubleshooting
Problem
Probable Cause(s)
Remedy
No power to fixture
Check power cables
Primary fuse blown
Replace fuse
No response from
fixture when power
is applies
Secondary
fuse
blown
Replace fuse
Controller
not
connected
Connect controller
Fixture resets but
does not respond
correctly
to Incorrect
Check address setting on fixture and controller