background image

 

 

Cable Connectors

 

Cables must have a male XLR connector on one end and a female XLR connector on the other end.

 

A word on termination: DMX is a resilient communication protocol, however 

errors  still  occasionally  occur.  Termination  reduces  signal  errors,  and  therefore  best  practices  include 

use of a terninator in all circumstances. If you are experiencing problems with erratic fixture behavior, 

especially over long signal cable runs, a terminator may help improve performance.

 

To build your own DMX Terminator: Obtain a 120-ohm, 1/4-watt resistor, and 

wire it between pins 2&3 of the last fixture. They are also readily available from specialty retailers.

 

 

 

Master and slave: select one machine as master,

 

press the menu to choose the function 

you want. Press other machines’ address to be DMX state. Use signal cable to connect 
machines one by one. Then slave machines will run the same as master machine.

 

Use controller to control lot of machines: if all machines are set the same menu data, or 
different manual data, after use signal cable to connect to controller, all machines will be 
controlled by controller. (before connect to controller, all machines should be in the same 
channel mode 5ch or 2ch).

 

 

 

 

 

 

 

 

Section 3. Troubleshooting

 

Problem

 

Probable Cause(s)

 

Remedy

 

No power to fixture

 

Check power cables

 

Primary fuse blown

 

Replace fuse

 

No  response  from 

fixture  when  power 

is applies

 

Secondary 

fuse 

blown

 

Replace fuse

 

Controller 

not 

connected

 

Connect controller

 

Fixture  resets  but 

does  not  respond 

correctly 

to  Incorrect 

Check address setting on fixture and controller

 

Содержание YR-COB5002

Страница 1: ...100W COB LED Model YR COB5002...

Страница 2: ...packing 1pc Fixture 1 4pc Signal Convertor Cable 1pc User Manual Thanks for choosing our product Carefully unpack the box and check the contents to ensure that all parts are present and in good condit...

Страница 3: ...re to replace with same fuse lamp size and type Cut off power before moving repairing and cleaning the machine To avoid electric shock all fixtures must be connected to circuits with a suitable earth...

Страница 4: ...nnection Installation This machine should be mounted through the screw holes of truss Safety rope is a must to fix fixture well Make sure truss and safety rope have strong load capacity to bear more t...

Страница 5: ...on Menu Switch menu function UP Scroll upwards DOWN Scroll downwards ENTER Confirm by pressing ENTER 3 DMX Signal Input 3 PIN XRL port for DMX512 signal input daisy chain 4 DMX signal output 3 PIN XRL...

Страница 6: ...ne machine as master press the menu to choose the function you want Press other machines address to be DMX state Use signal cable to connect machines one by one Then slave machines will run the same a...

Страница 7: ...res one at a time until normal operation is regained unplug both connectors and connect them directly together Colors cannot be mixed Random color mixing is on Turn off random color mixing Fixture doe...

Страница 8: ...dr 1 Dimmer Curve1 dr 2 Dimmer Curve2 dr 3 Dimmer Curve3 dr 4 Dimmer Curve4 DMX protocol DMX512 Channel Chart 5CH CH Function Specification CH1 All Dimmer 0 255 RGBW Dimmer from dark to bright CH2 PW...

Страница 9: ...Curve 3 dr 3 1600 1710 Dimmer Curve 4 dr 4 1850 1980 Specification Voltage AC110V 240V Frequency 50 60Hz Machine Power 100W LED source 50W PW 50W WW LED QTY 1pcs Strobe 0 20 Hz Dimmer 4 kinds of dimme...

Страница 10: ...Size 26 26 11 5cm excluding bracket Our company reserve right to revise this user manual without notice Innovation Efficiency Dedication Harmonious...

Страница 11: ......

Отзывы: