background image

ManTooth

-V  

Wireless Vacuum Gauge

ManTooth

-PTV  Wireless

Digital Vacuum & P/T Gauge

User’s Manual

Made for iPhone SE, iPhone 6s, iPhone 6, 
iPad mini 3, iPad Air, iPad mini 2 

iPhone and iPad Retina are trademarks of Apple Inc., 

registered in the U.S. and other countries. iPad Air

and iPad mini are trademarks of Apple, Inc.

 Android and Google Play are trademarks of Google Inc.
The Bluetooth® word mark and logos are registered 

trademarks owned by Bluetooth SIG, Inc. and any use

of such marks by Ritchie Engineering is under license. 
Other trademarks and trade names are those of their 

respective owners. 

“Made for iPhone” and “Made for iPad” 

mean that an electronic accessory has been 

designed to connect specifically to iPhone, 

or iPad, respectively, and has been certified 

by the developer to meet Apple 

performance standards. Apple is not 

responsible for the operation of this device 

or its compliance with safety and regulatory 

standards. Please note that the use of this 

accessory with iPhone, or iPad may affect 

wireless performance.

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Содержание ManTooth-PTV

Страница 1: ...uch marks by Ritchie Engineering is under license Other trademarks and trade names are those of their respective owners Made for iPhone and Made for iPad mean that an electronic accessory has been des...

Страница 2: ...s described in this Users Manual otherwise the protection provided by the equipment may be impaired Do not use the instrument if it is damaged Before you use the instrument inspect the case Look for c...

Страница 3: ......

Страница 4: ...adio on if it is not already on Next turn your ManTooth Module on by pressing and releasing the power button on the main module The module will go through a brief start up sequence then the light on y...

Страница 5: ...settings and procedures of the ManTooth RSA If you have not already downloaded the Yellow Jacket ManTooth RSA App go to either the Apple App Store or the Google Play Store now to download the free ap...

Страница 6: ...ds per square inch absolute psia pounds per square inch gauge psig bar kilopascals kPa Megapascals MPa and kilogram per square centimeter kg cm 2 The default pressure units are pounds per square inch...

Страница 7: ...ly turn itself o after a designated period of time It can be set anywhere from 1 to 90 minutes After the ManTooth Module has been connected for the speci ed auto o time an alert will pop up asking if...

Страница 8: ...is mandatory before moving to the next screen To save a favorite refrigerant click on the star icon next to the refrigerant Once a refrigerant is selected as a favorite the star will turn yellow and t...

Страница 9: ...his data is saved to the Service History under Un named Location and is sorted simply by date and time You can not assign a location to data at a later time To select the location click on the arrow n...

Страница 10: ...desired location from this list If a new location is needed click on the icon in the upper right hand corner of the screen lower right hand corner for Android users An equipment ID can now be entered...

Страница 11: ...you to the module selection screen iOS Android Tap on the ManTooth Module s that you wish to connect to your session from the list of devices that are displayed Remember your Module s name is the seri...

Страница 12: ...lay the pressures and temperatures as measured by the ManTooth Module s display the liquid and vapor saturation values as well as calculate and display the superheat and subcooling values The rst time...

Страница 13: ...creenshots can be taken from the readings screen to show the readings at any given point in the session To save the data currently on the screen tap on the screen shot icon on the top right corner of...

Страница 14: ...l buttons on the readings screen The rst is a refresh button next to the screenshot button at the top of the screen This will reset the minimum maximum and average readings of the session This functio...

Страница 15: ...to the Service History under Un named Location and is sorted simply by date and time You can not assign a location to data at a later time For more details on setting location and equipment see the Pr...

Страница 16: ...ntdown timer will reset to the originally established target time and will resume once the reading returns to the target vacuum level When the target vacuum level has been maintained for the target ti...

Страница 17: ...t is not exceeded during the target duration a PASS notification is displayed Saving Sharing Data At any point in the vacuum session Evacuation Mode or Hold Test Mode data can be saved and shared For...

Страница 18: ...g line On Android devices saved screenshots are saved with a green square icon whereas data logs are saved with a red square icon Any of these saved data items can be selected and shared or deleted Fo...

Страница 19: ...g your ManTooth Module off hold down the power button until the red light turns off about 2 seconds Inch Flare Fitting Vacuum Gauge The vacuum gauge plugs into the back of both the ManTooth V and ManT...

Страница 20: ...kPa 0 1 Pa Vacuum Sensing Accuracy 20 from 25 microns to 10 000 microns Vacuum Range 6 microns to 100 000 microns Working Temperature 4 F to 160 F Limited by battery Storage Temperature 4 F to 160 F F...

Страница 21: ...d ManTooth PTV Modules have a Self Healing feature If the Bluetooth connection is lost during a session the app will attempt to re connect to the ManTooth Module and maintain the session data log Once...

Страница 22: ...gauge through the side port of a core removal tool such as the YELLOW JACKET 18975 If the system only has one accessible service port the vacuum gauge can also be attached to the inch male flare port...