background image

Yealink DECT Phone System Deployment Guide 

This chapter describes how to choose appropriate locations for base stations and 
repeaters on different sites. The purpose of this chapter is to familiarize you with the 
procedures that are needed to carry out a site plan. 

The following equipments are required for the deployment: 

 

Base Station 

 

Handset 

 

Repeater 

The following explains the procedures required to identify the quantity and position of 
the base stations at prospective customer sites. 

Note 

When deploying in a single floor building (the width of the building is less than 100 
meters), the deployment process consists of the following steps: 

 

Identifying initial critical points on the floor plan 

A critical point is a place that can be difficult for the radio signal to reach, such as a 
corner of a room, lifts and stairwells. Determine the critical points for placing the 
deployment base stations. 

1.

 

Select the first critical point located in the corner furthest from the center areas 
of the premises. Name this point P1. 

2.

 

Select a nearby critical point adjacent to the first one and name it P2. 

 

Locating the area center of the first base station 

1.

 

Place the deployment base stations on the critical points.   

2.

 

Set up communications between base stations and cordless handsets.   

3.

 

Measure the radio coverage and determine the limit of the radio coverage of 
two critical points. 

4.

 

Determine the intersection point of the boundary lines of different radio 
coverage cells. An intersection point will indicate the possible best location for 

The following figures do not consider building elements that may influence the signal 

strength. 

Содержание Telkom W52P

Страница 1: ......

Страница 2: ...nal quality Selecting a proper mounting location for base stations and repeaters Operating and configuring of the base station repeater and handset The following related documents for W52P IP DECT pho...

Страница 3: ...s and Site Density 5 Deployment Guidance 6 Deploying W52P DECT Phone System 6 Deployment in a Single Floor Building 6 Deployment in a Wider Single Floor Building 8 Deployment in a Multi Floor Building...

Страница 4: ...ding architecture and wall material Outside in free air radius 300m depending on reflections and surroundings Yealink DECT repeater RT10 is designed in accordance with DECT standard The RT10 repeater...

Страница 5: ...Construction materials such as walls floors ceilings Type of use such as for office hotel factory or store Dimensions Number of floors Height of floors Partitioning of floors The following table gives...

Страница 6: ...may exist where each group of users has mobility within their own system cell single base station coverage area As users have no mobility over the whole local site the phenomenon of increasing number...

Страница 7: ...t is a place that can be difficult for the radio signal to reach such as a corner of a room lifts and stairwells Determine the critical points for placing the deployment base stations 1 Select the fir...

Страница 8: ...s The final position is again the intersection point of the radio coverage cells indicated by the broken lines shown by position 6 in the following figure 5 Follow the above steps to locate area cente...

Страница 9: ...t Measure the radio coverage and determine the limit of the radio coverage of the critical point Measure the signal in a 45 degree angle towards the center of the area Proceed to the critical point P2...

Страница 10: ...the floor above then measure the horizontal coverage at this location 3 Without moving the base station go to the floor directly below and measure the horizontal coverage at this location 4 Arrange th...

Страница 11: ...ore user dense site The deployment process consists of the following steps Count the total number of users and associated traffic in the local site Define the homogeneous traffic areas Calculate the a...

Страница 12: ...o install the repeaters in series or daisy chain Repeater has the same radio coverage up to 300m in unobstructed outdoor areas and up to 50m inside buildings as the base station Repeater does not incr...

Страница 13: ...r within the base station coverage area The separation distance between the base station and repeater is 30m The base will hand over calls to the repeaters as the user moves from the base station cove...

Страница 14: ...ce from your handset follow these recommendations Keep the base station repeater away from steel constructions at least 4 feet 1 20 meters Do not place base station repeater directly on metallic surfa...

Страница 15: ...e devices is twice as large as the coverage at the rear The base stations should always be mounted higher that the obstructive objects in the area e g minimum higher than 2m above floor Repeaters shou...