2
2
Endpoint Installation
We recommend 2 people working together to mount ETV65, 4 people working together to mount ETV86.
If you are using a floor stand for installation, please refer to
Quick Start Guide
(Floor-Mounted)
.
ETV65
ETV86
Take and place all components gently to avoid damage.
1490mm (65 inches)
1968mm (86 inches)
97mm
26mm
936mm (65 inc
hes)
1210mm (86 inc
hes)
1. Please install on a vertical, load-bearing solid wall or concrete wall (use expansion
screw) or planks, other reinforced walls (use self-tapping screws) with more than
20 cm thickness.
2. For other type of walls, please reinforce the wall and verify the feasibility before
installation. Verification method: Install a screw to carry out a single screw load
test for 1 minute (ETV65 load-bearing 35 kg, ETV86 load-bearing 45 kg), and the
installation can continue if the screw is not loose.
3. The wall-mounted bracket for ETV65 and ETV86 are only different in size, and the
installation method is the same.
4. The installation height data is for reference only. You can choose a suitable posi-
tion as needed.
1