6. Auto Defrost
When the dehumidifier is running at a lower temperature, the system will
automatically determine whether there is a presence of frost. If any frost exists, it will
defrost automatically.
Defrost Action: The fan will keep running and the compressor will stop.
When Defosting: The defrosting character or icon "
" will flash.
Defrost
When Defrosting Stops: The defrosting character or icon "
" will go out, the
Defrost
fan and the compressor will both work according to dehumidification requirements.
7. Temperature Protection Function
When the ambient temperature is higher than the Default Highest Temperature
(113°F), the system will enter high temperature protection, the small figure on the
screen will indicate "HH", and the compressor will stop.
When the ambient temperature is lower than the Default Lowest Temperature (39 °F),
the system will enter the low temperature protection, the small figure on the screen will
indicate "LL", and the whole machine will stop.
5. Display Status Description
When the fan is delayed, the running icon "
" will flash, and if the fan
Running
is running, the running icon "
" will be on, otherwise it will be off.
Running
When the compressor is delayed, the dehumidification icon "
"
will flash, and if
the compressor is running, the dehumidification "
"
icon will be on, otherwise it
will be off.
If the ambient humidity is lower than the setting humidity, the compressor will be
stopped, and the humidity control icon "
"
will flash, otherwise it will
Wet Controller
be off.
When the machine needs to be cleaned, the cleaning icon "
"
will flash,
otherwise it is off.
When the machine is defrosting, the defrost icon "
"
will flash, and go
Defrost
out when the defrosting ends.
3. In the case of continuous power, the compressor can only be restarted after 3
minutes after.
3. Screen Description
Big Font Digital Number
(
59 RH%
in the above illustration) is humidity
percentage reading of the inlet air that the dehumidifier detects which is similar to
the room humidity level. When you are pressing the or button to set a desired
humidity percentage value, the big font digital number will turn to display the
setting value and flash.