10
O P E R A T I N G M A N U A L
GB
PROPERTIES OF THE DEVICE
The all-purpose meter is a
digital measurement instrument designed to measure distinct electrical quantities. In case of certain meas-
urement quantities the meter adapts an adequate range depending on the result of the measurement.
Before using the meter, read the whole manual and keep it.
The meter has a plastic housing, a liquid crystal display and a measurement range switch. The housing is equipped with measurement
sockets and a transistor check socket. The meter is equipped with measurement cables with plugs. The meter is supplied without a
battery.
ATTENTION! The meter is not a measurement device as it is construed within the „Measurement Law”
TECHNICA DATA
Display: LCD 3 3/4 digits – maximum displayed result: 3999
Sampling frequency: approximately 2-3 times per second
Overload signalling: digit „OL” is displayed
Polarization signalling: symbol „-” is displayed before the result of the measurement
Battery: 6F22; 9 V
Working temperature: 0 ÷ 40°C at the relative humidity <75%
Storage temperature: -10°C ÷ +50°C; at the relative humidity <85%
External dimensions: 162 x 83 x 47 mm
Weight: approximately 310 g
ATTENTION! It is prohibited to measure electrical quantities exceeding the maximum measurement range of the meter.
Parameter
Direct voltage
Alternating voltage
Direct current
Alternating current
for the range 400 mV: R
IN
> 1000 M
Ω
;
other ranges: R
IN
= 10 M
Ω
R
IN
= 10 M
Ω
; f
IN
= 40 ÷ 400 Hz
U
AB
≤
400 mV
f
IN
= 40 ÷ 400Hz
Catalogue number
Range
Resolution
Precision
Range Resolution
Precision
Range
Resolution
Precision
Range
Resolution
Precision
YT-73087
400 mV
0,1 mV
±(1,0% + 5)
4 V
1 mV
±(1,0% + 5)
400
μ
A
0,1
μ
A
±(1,2% + 3)
400
μ
A
0,1
μ
A
±(1,5% + 5)
4 V
1 mV
±(0,8% + 3)
40 V
10 mV
4000
μ
A
1
μ
A
4000
μ
A
1
μ
A
40 V
10 mV
300 V
100 mV
40 mA
0,01 mA
40 mA
0,01 mA
300 V
0,1 V
400 mA
0,1 mA
400 mA
0,1 mA
4A
0,001 A
±(1,8% + 3)
4A
0,001 A
±(2,0% + 5)
10 A
0,01 A
±(2,0% + 5)
10 A
0,01 A
±(3,0% + 10)
Remarks
Overload protection: 300 V
Overload protection: 300 V
Overload protection: fuse 250 mA/300 V; range 10 A: fuse 10 A/300 V- measurement
of the current > 2A , duration of measurement < 15 s. in intervals > 15 min.
Parameter
Resistancea
Capacity
Frequency
Diode tests
Catalogue number
Range
Resolution
Precision
Range
Resolution
Precision
Range
Resolution
Precision
Conditions for measurement
YT-73087
400
Ω
0,1
Ω
±(1,0% + 5)
4 nF
0,001 nF
±(4,0% + 5)
10 Hz
0,01 Hz
±(1,0% + 3)
I
F
= 1 mA
U
R
= 1,5 V
4 k
Ω
1
Ω
±(1,0% + 3)
40 nF
0,01 nF
100 Hz
0,1 Hz
±(0,8% + 3)
40 k
Ω
10
Ω
400 nF
0,1 nF
1 kHz
0,001 kHz
400 k
Ω
0,1 k
Ω
4
μ
F
0,001
μ
F
10 kHz
0,01 kHz
4 M
Ω
1 k
Ω
40
μ
F
0,01
μ
F
100 kHz
0,1 kHz
±(1,0% + 3)
40 M
Ω
10 k
Ω
±(2,0% + 5)
100
μ
F
0,1
μ
F
±(8,0% + 5)
200 kHz
1 kHz
> 200 kHz
undetermined
Remarks
Open circuit voltage approximately
0,25 V;
Precision does not take into account the er-
ror implied by the capacity of the meter and
measurement cables. For ranges
≤
200 nF
the result must be reduced by the capacity
of the meter and the measurement cables
Input voltage range: 1 V rms ÷ 20 V rms;
Содержание YT-73087
Страница 24: ...24 RUS x10Lux Lux 10 S rel...
Страница 29: ...29 UA x10Lux Lux 10 S rel...