background image

®

shanghai Yatai Instrumentation., Co., Ltd.

                                                                                             

GDJ

 series Photoelectric detecting sensor 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

  Installation and Wiring 

1.

 

The  sensor  should  be  set  up  vertically  on  the  top  of  the  measured  object.  The 

distance between the surface of measured object should be approximately 10mm 

to  the  sensor  lens  according  to  the  different  model.  The  vertical  adjustment 

distance of mounting base plate should be 10mm. 

2.

 

The sensor has four wires which differentiated by its color. Wiring shown in the 

diagram below. Red and blue wires respectively are positive and negative power 

wire; connect with DC power supply. Yellow wire is the bright open output wire 

and  grey  one  is  the  dark  open  output  wire;  these  two  wires  regard  as  the  NPN 

type switch control output. One of these two wires should be chosen depends on 

customers

 needs and the other one should be insulated. 

 

 

 

 

 

 

GDJ-612 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

Sensitivity adjustment

 

In general, 

No matter the light aims to the deep color or light color object

Rotating 

the knob of sensitivity by clockwise, then the green light (OUT 1) turns on. 

Firstly: Make the light-spot aims to the dark color side of object (Generally as color 

patch), adjust the Sensitivity knob, and make the green light-spot just be in the status 

of disappeared, remember the position of the knob (Notes A). 

Secondly:  Make  the  light-spot  aims  to  the  light  color  side  of  object  (Generally  as 

background color), adjust the Sensitivity knob by anticlockwise, and make the green 

light-spot  just  be  in  the  status  of  disappeared,  remember  the  position  of  the  knob 

(Notes B). 

Thirdly: Turns knob to the middle of A and B. 

Notes:  Because  the  Sensitivity  knob  is  multiturn  potentiometer.  Not  only  remember 

the position of A and B, but also remember the number of knob turns. Then, turn back 

the knob to the middle of number of knob turns. 

Shanghai Yatai Instrumentation 
Co., Ltd. 

Address:  No.128  Zhen  Yuan  Road  Shanghai 
China        Post Code: 200444 

Tel:021-66186368

             

Email

yatai@yatai.sh.cn                 

 

RED  VDD

+10-30V

LOAD

RL2

L

O
A
D

RL1

Circuit

4.8K

4.8K

YELLOW

GREY

BLUE  OVDC

36V

36V

10

3

 4    GDJ-61     

1
2

3,5

15,3

25

3.2*2

通孔

9

23,5

89

·

Отзывы: