14.1 Drives
1
4
-5
Model CIMR-M5
j
*
2
CIMR-MR5
j
*
2
45P5
47P5
4011
4015
4018
4022
4030
4037
4045
Ambient Temperature
0
°
C to 55
°
C (32
°
F to 131
°
F) (not frozen)
oller
Heatsink Intake Air Temperature
0
°
C to 45
°
C (32
°
F to 113
°
F)
C
ontrol
l
m
on
Storage Temperature
*6
−
20
°
C to 60
°
C (
−
4
°
F to 140
°
F)
C
Com
m
Humidity
90% or less (non-condensing)
C
Location
Indoor (protected from corrosive gases and dust), elevation: 1000 m (3280 ft) or less
Vibration
9.8 m/s
2
(1G) at 10 to less than 20 Hz, up to 2 m / s
2
(0.2G) at 20 to 50 Hz
Protective Structure
IEC IP00
(Protected so that parts of the human body cannot reach electrically charged parts from the front)
* 1. Rated output power is guaranteed when input voltage is three-phase, 400 V (50/60 Hz), 440 V (50/60 Hz), 460 V (60Hz). If
input voltage is lower than 400 V, rated output power is not guaranteed.
* 2. A: For stand-alone drive system N: for NC system
* 3. If the heatsink input temperature for the 4037 and 4045 Inverter is high, the bearable load is limited. The continuous use time
at 1 minute rated value (120% of 30 minutes rated output) depending on the Unit heat limit is shown in the following diagram.
* 4. Dimensions of External Heatsink Cooling Type. Refer to
14.1.3 Dimensions
for Open Chassis Type.
* 5. An AC reactor is required between Converter and main circuit power supply.
* 6. Temperature during shipping.
0
20
40
60
0
10
20
30
40
50
15
37.5
Heatsink input temperature (
_
C)
1 Minute Rated Continuous Use Time for 4037 and 4045 Inverters
1
min.
rated
continuous
use
time
(seconds)
14